Eddy Current
1) non-contact position, displacement, and proximity measurements. 2) applied in NDT to find flaws in conductive metal.
-
product
Current Signature Analysis
The Iris Power MDSP3 uses the Current Signature Analysis technology which relies on the concept that faults in the induction motor rotor or driven components result in changes to the rotor magnetic field pattern. Unique magnetic rotating fields are produced due to the faults which induce detectable stator current components indicative of the fault.
-
product
Resistive Current Tester
Weshine Electric Manufacturing Co., Ltd
Long Distance Digital Zinc Oxide Arrester Resistive Current Safety Testing Set
-
product
Current Probes
Innovative DC to 5MHz "positional" current probe capable of measuring currents in PCB tracks, component legs etc. without the need to break the connection or surround the conductor.
-
product
Dual Surge Current Generator
MIG0612T-K12
Designed for testing telecom surge protection devices according to ITU-T K12. The generator has two indepedent impulse outputs which allow testing of two and three terminal protection devices such as gas discharge tubes (GDT). The generator can be configured for two terminal devices or with the outputs in parallel to increase the current impulse for two terminal devices.
-
product
AC Current Sensor
LFR
The LFR ac current probe has been designed to have market leading low frequency performance, meaning low phase shift and low noise. This compact, low cost, clip-around probe is both flexible and dual-range, and is optimized to give minimal phase measurement error at frequencies from 45Hz to 20kHz and have a very low noise floor.
-
product
500A AC/DC Current Sensor
CT6904
Hioki pull-through AC/DC current sensors are best-in-class devices for use with power analyzers,, Memory HiCorders and high performance oscilloscopes. The CT6904 is a DC to 4 MHz/500A sensor, ideal for capturing current signals from switching power supplies, inverters, power conditioners, etc.
-
product
DC current Sensors
CTH
The CTH sensors convert dc current to an isolated voltage output, the CTHR sensors convert ac current to a dc output signal proportional to the Arms. All popular process control voltage and current loop outputs are available. Through hole or split core options mean that connection is non-intrusive and straightforward. The available input range of the CTH sensors is any value from 5A to 6000Adc.
-
product
Current Transformers
National Meter Industries Inc.
Is an instrument transformer, used along with measuring or protective devices, in which the secondary current is proportional to the primary current (under normal conditions of operation) and differs from it by an angle that is approximately zero.
-
product
Clamp type AC Current Sensor/for Load Current Measurements(CT Series)
CT-80
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Big CT window*AC 1A~1800A*Current measurements of main cable
-
product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-1000B Open loop method
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
product
Current Clamp Meter
CP 41
The CP 41 current clamp meter has been designed for reliable and accurate, non-intrusive measurement of AC, DC and complex waveform currents. Using advanced Hall Effect technology the CP 41 can measure currents accurately from 5mA to 40Amps.
-
product
Wet Leakage Current Test
King Design Industrial Co., Ltd.
The outdoor solar module will endure the erosion of rain, fog, snow and sandstorm. To make sure that solar module will not wet leakage current accident and tolerate huge load pressure in such harsh conditions, we adopt wet leakage current to simulate the above weather conditions.
-
product
Programmable ProBus Current Adapter
CA10
The CA10 is a programmable and customizable interface device that seamlessly incorporates third party current transducers/transformers with Teledyne LeCroy oscilloscopes or motor drive analyzers. It allows the third party device to be recognized and operate as if it were a Teledyne LeCroy probe.
-
product
DC Bias Current Source
TH1778A
Changzhou Tonghui Electronic Co., Ltd.
The instrument adopts a new generation AC/DC superposition test theory to adapt test requirements for high precision and high frequency. The built-in embedded MCU with high-performance can quickly respond to host and slave machine condition or malfunction and make real time indication, which helps improve the work efficiency. The new designed friendly graphical operation interface, included 5-foot control modes and full touch operation provides convenience and efficiency for users. New file management system with easy, prompt and accurate operation can save a group of real-time setting file and 99 groups of user defined setting files. It can provide pushed information indication and cache 2 real-time information. Being provided with two modes of SCPI instruction systems, it is convenient to set up production lines or single machine test. Also, it can connect with any device with serial port and which refer to the SCPI instruction system design of this machine.
-
product
Current Transformers And Shunts
Current transformers allow the different measuring devices to provide reliable and traceable data on the trends involving consumption and production processes in electrical installations. Especially designed to be installed quickly, easily and securely, meeting the most demanding expectations of today's market, covering a wide range of primary currents as well as multiple secondary outputs, both for AC and DC measurement.
-
product
Current Feedback Op Amplifiers
Analog Devices high speed (> 50 MHz) current feedback op amps enable you to operate at higher speeds. Current feedback op amps traditionally have wider bandwidths and higher slew rates than voltage feedback amplifiers and do not feature a gain bandwidth restriction associated with voltage feedback op amps.
-
product
NI-9266, 8-Channel C Series Current Output Module
785047-02
8-Channel C Series Current Output Module - The NI‑9266 is ideal for interfacing and controlling industrial current-driven actuators. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9266 includes channel‑to‑earth ground isolation for safety and noise immunity.
-
product
Integrated Current Sensors
GO series
*Standard package and small footprint*Cost effective*A perfect compromise for small drives, robots, solar inverters, e-bikes etc.
-
product
Current Monitoring, Power Relays
DI Series
Heavy duty, current monitoring relay for demanding applications. Current activated coil.
-
product
Current Logger Sensor
NUL-202
This sensor can be used to measure the current in parallel or series branches of low voltage AC and DC circuits and also to investigate the dependence of the current flow through components on the voltage across them.
-
product
AC and DC Current Sources
Programmable AC and DC current sources that provide precise, low noise, stable currents for a number of applications.
-
product
Clamp type AC Current Sensor/for Load Current Measurements(CT Series)
CT-33S
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Ultra compact size*AC 1A~200A*Current measurements of feeder
-
product
Fluxgate 150A Current Sensor
LF03
Our LF03 current sensor works with the dynamic Fluxgate measurement technology. It is characterized by its simple, practical design and prevents high temperature drifts. Fluxgate technology uses the phenomenon of magnetic saturation to modulate the measured magnetic field and convert it into an electric field.
-
product
Precision High Current Resistors/Shunts
Measurements International Ltd.
The precision high current shunts are a series of High Current Resistors ranging from 1 A to 3000 A with optional air moving fans and resistance values from ohms to micro-ohm.
-
product
DC Leakage Current Monitor
MDLA-100
MULTI MEASURING INSTRUMENTS Co., Ltd.
This DC Leakage Current Monitor constantly observes leakage current of DC circuit like as PV generation system, etc. and lights up the warning lamp with signal output, when the leakage current exceeds the setting value.
-
product
AC Current Probes
CWT
Power Electronic Measurments Ltd
The CWT Rogowski current probe is suitable for measuring AC currents ranging from 300 milliamps to hundreds of kA from below 0.1Hz to >30MHz.
-
product
Current Differential Relay
SEL-587
Schweitzer Engineering Laboratories, Inc.
The SEL-587 Current Differential/Overcurrent Relay provides protection for any two-input apparatus, such as transformers, motors, generators, and reactors. Apply it for differential and overcurrent protection and use event reports for quick post-event analysis.
-
product
Secondary Current Injection Test Trolley
SCR ELEKTRONIKS have developed SECONDARY CURRENT INJECTION TEST TROLLEY for Switchgear items, CT manufacturer and where three phase current application is called for. It is low Voltage, 3 phase Current source with control circuitry, digital read out for test current and trip time measurement. We can select different CT ranges for each phase independently and adjust the current as per the required test Current.
-
product
Wireless Primary Current Recorder Meter
GF2015
Beijing GFUVE Electronics Co.,Ltd.
GF2015 is a wireless primary current recorder equipped with a 433M for transmit the recorded data into the user''s PC by our PC-Link Software. It is a good assistant of power monitor system. The recording interval can be set from 1- 60 min. The PC-Link Software can generate reports and create graphs for profile analysis.
-
product
Bulk Current Monitoring Probe
MP-50
The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.





























