Eddy Current
1) non-contact position, displacement, and proximity measurements. 2) applied in NDT to find flaws in conductive metal.
-
Product
Current Measurements of PWM or Inverter, AC/DC 10~200A, φ24mm
CTF-200DC
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 10~200A*Current measurements for PWM or inverter
-
Product
AC Current Shunts
-
AC Current Shunts feature low uncertainty (high accuracy), low temperature coefficients and excellent stability. These shunts are purely resistive with extremely small values of reactance. The 7340 shunts may be used over a wide frequency range from DC to 100 kHz and are optimized for use with thermal converters.
-
Product
Current To Pressure Measurement Trainer
-
Unitech Scales And Measurements Pvt. Ltd
Current to Pressure Trainer. This setup comprises of a I to P converter fitted on a base. Two pressure gauges are fitted one at the input side and the other at the output of the I to P converter. A current source with digital display is provided to excite the I to P converter. A constant air supply should be provided to the system at 20 PsI Pressure from a standard compressor.
-
Product
Current Transformers
-
The Institute of Electrical and Electronic Engineers defines a current transformer (IEEE Std C57.13) as “a transformer intended to reproduce in its secondary circuit, in a definite and known proportion, the current of its primary circuit with the phase relations substantially preserved”. Its primary winding is connected in series with the conductor carrying the current to be measured or to be controlled and its secondary winding is connected to the measuring, protection or control devices. Osborne designs and manufactures current transformers which are used for instrumentation applications, others which are used for power system synchronizing applications and others which are used in protection circuit application. They have been designed to meet specified current ratios, burden impedance and transformation errors.
-
Product
PC Based High Current Test Set for Circuit Breakers and Temperature Rise Test Equipment
-
This equipment comprises of high current source for testing of circuit breakers with additional facility for temperature rise testing (thus incorporating testing for moulded case, vacuum & air circuit breakers as per IEC 60947-2). The system integrates a servo controlled source with closed loop current feedback to maintain the current constant. It has the necessary instrumentation for maintaining current at full load & other conditions arising in testing at high current. The bench has a PC based control system with temperature data logger (24 channel with ch-ch isolation amplifiers). The data logger displays as well as stores a set of temperature values with time.
-
Product
Current Source-Sink D/A Converters
-
Analog Devices’ current source D/A converters (DACs) portfolio is ideal for photonics control applications where low current noise density, low dropout voltage, and high power efficiency, in addition to high channel density, is critical to system performance. The flexibility of the configurable current source D/A converter outputs, and 300 mA current delivery, make them suitable for resistive heaters and proportional solenoid drive.
-
Product
Current Integrated Sources
CIS
-
The CIS current integrated source was designed to provide a stable alternating current source for the electricity meter test equipment, and in laboratories. The output current is isolated and independent from the mains voltage. Different CIS versions are available depending upon the values of output power and output current required.
-
Product
Precision AC/DC Active Current Shunt
2575A
-
A versatile, powerful calibration tool, the 2575A Precision AC-DC Active Current Shunt measures both AC/DC current and works as a standard for low-level resistance calibration requirements.
-
Product
MCB Tripping Current Characteristic Test Bench
-
The SCR Elektroniks 12 station MCB Tripping Characteristics Test Bench is optimally designed to verify the Tripping Characteristic of MCBs as per clause 9.10.1 of IEC 60898 (Also mentioned in Indian Standards IS 8828). The bench essentially comprises of Servo Controlled mechanism to set and maintain desired current (against incoming mains fluctuation) and a Micro controller based master controller unit plus timer, which governs the entire sequence of operation making it a stand-alone system once the user connects the MCB and configures the test parameters.
-
Product
Thermistors (Temperature Sensors, Current Control)
-
The resistance value changes in response to temperature changes in the ambient environment or due to heat generated by applied voltage or current.
-
Product
High Current Calibrator
MC151
-
MC151 Current calibrator is an accurate current source capable of 120 A. Typical uses include calibration of current sensors, current probes, current transformers, shunts, ammeters, DMMs or as stable current source for test and development applications. The calibrator is equipped with a built-in multimeter that can be used for simulation of programmable transconductance or current amplifier.
-
Product
Current Measurements Of PWM Or Inverter, AC/DC 10~200A, Φ24mm
CTF-200DC-U24V
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 10~200A*Current measurements for PWM or inverter
-
Product
Current Clamp Meter
CP 41
-
The CP 41 current clamp meter has been designed for reliable and accurate, non-intrusive measurement of AC, DC and complex waveform currents. Using advanced Hall Effect technology the CP 41 can measure currents accurately from 5mA to 40Amps.
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Dual 12-Channel, 1-Pole
42-514-107
Multiplexer Module
The 40-514-107 (PXI) and 42-514-107 (PXIe) are low density multiplexers in dual 12-channel, 1-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
20A Auto Current & Voltage Tester
7610
-
Peaceful Thriving Enterprise Co Ltd
Fast, accurate and safe current measurement at the fuse box.Ideal for fault-finding on car and commercial vehicle electrical circuit.
-
Product
Impulse Current Measuring Shunts
ICMS
-
The Impulse Current Measuring Shunts ICMS are new designed tubular shunt types with best response behavior to match the high performance of the TR-AS digital recorder for comparative current measurements. A 1st partial response time less than 10ns and a settling times less than 20ns show the advantage of these shunts. They show no initial overshoot peak, no oscillations and do not need compensation box to optimize the transient behavior as known from e.g. cage shunts.
-
Product
Current Probe
-
Beijing GFUVE Electronics Co.,Ltd.
Used to measure control currents for relays in electronic circuits and in evaluation testing of capacitors' current characteristics.
-
Product
Current Measurements Of PWM Or Inverter, AC/DC 1~50A, Φ16mm
CTF-50DC-U24V
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 1~50A*Current measurements for PWM or inverter
-
Product
SAFETY TESTERS ( CURRENT LEAKAGE TESTERS )
ST-05
-
Safety Tester Model ST-05 is a test set for testing small equipment powered by 120V 60 Hz, from an approved U-ground source. Test also can be run on double-insulated tools an on appliances with two-pin parallel plugs.
-
Product
High Frequency Current Transformers
-
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
Product
Low Input Bias Current Op Amps (≤100 pA)
-
Low input bias current op amps are required whenever the difference of currents or voltage is small and needs to be measured accurately. These op amps are used so that the signal is not loaded down by the input of the op amps. Low input bias current op amps are critical for interfacing sensors in applications from photodiodes, pH meters, or other electrometer related functions to downstream electronics. Analog Devices has many precision op amps that fit the definition and range of these applications.
-
Product
Primary Current Injection Sets
-
Protective devices such as relays, overload Coils, Circuit breakers and CTS etc. must be checked regularly to ensure that they are always ready to operate correctly, Routine current injection testing will quickly detect faulty or incorrectly adjusted protection circuits / devices & will be possible to prevent serious damage to the system. Primary injection kit is designed to operate on single phase 230/240 volts AC 50 HZ to develop smooth & continuous test current as for loading, calibrating, and testing of CTS, Bimetal Relays, Protection Relays etc. The test set gives high current output at low cost and with inherent safety. The primary current injection testing checks all parts of the protection system by injecting current down the cable / bus bars. The application of the primary current injection sets is to ascertain the current carrying capacity of any Conductor, insulator, connector or calibration of CTS / Bi-metallic relays etc.
-
Product
150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 Meter Cable
CP150-6M
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Digital Ior Leakage Current Clamp Tester
MCL-400IR+
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・About Ior Leakage CurrentRecently, the leakage current clamp meter is widely used for insulation control of low voltage circuit as the supplementary method of the insulation resistance measurement. The control of leakage current has the advantages to enable the prediction of insulation condition in the electrical power line without having to shut off the power. The leakage current (Io) includes the capacitive leakage current (Ioc)originated in the capacitance and the resistive leakage current (Ior) originated in the insulation resistance each related to the ground. It is considered that the measurement of resistive leakage current (Ior) is the very useful and effective method for the insulation control of low voltage circuit. However, it was difficult to measure the resistive leakage current (Ior)with traditional leakage current clamp meter. MCL-400IR new digital clamp tester enabled the measurements of the resistive leakage current (Ior)without voltage input(phase detection).
-
Product
Extra-Ground Current Impuision Equipment
JYQ
-
Generally, the way of finding out the iron core ground false of powertransformer is always inefficient, while the method of using the traditional measure such as increase powerful current by welder when finding the false point oftransformer. The transformer needs to be mended on the spot or return to the factory if it can not melt off the point because of low voltage. It will spend high transportation fee and dealing costs, brings huge economic loss. The JYQ iron-coreimpulsionequipment is the intelligence set for exclusiveusing in solving the false of transformer. It can output high-voltage powerful current transientand melt the ground point off rapidly.
-
Product
Resistors for Calibration of Current Measuring Systems and Sensors/Transducers
-
ChenYang Technologies GmbH & Co. KG
Is designed and made according to the Standard JB/T8225-1999 for DC resistors used in laboratory and electrical engineering.By using full closed structure and automatictemperature control it ensures resistor good long-term stability and small temperaturecoefficient. This DC resistor is very suitablefor DC current measurement and calibration of current measuring systems and current sensors. The maximal measuring current is 100A with measuring accuracy of ±0.02%
-
Product
Split Core Current Transformers
-
Application:Watt Transducer, Current Transducer, KWH Meter, Demand Meter, Power Factor Meter, Current Sensing Relays, Energy Management SystemsContinuous Thermal: Rating 1.25 at 30° C, 1.0 at 55° C Standard 5-amp secondary. Others available.
-
Product
Current Measurements of PWM or Inverter, AC/DC 5~100A, φ16mm
CTF-100DC
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 5~100A*For current measurements for PWM or inverter
-
Product
Programmable ProBus Current Adapter
CA10
-
The CA10 is a programmable and customizable interface device that seamlessly incorporates third party current transducers/transformers with Teledyne LeCroy oscilloscopes or motor drive analyzers. It allows the third party device to be recognized and operate as if it were a Teledyne LeCroy probe.
-
Product
Leakage Current Sensors / Small Current Sensors
-
ChenYang Technologies GmbH & Co. KG
This current sensor is based on magnetic modulation and compensation principle, and can beused for measurement of small DC current and leakage current, current difference between two ormore conductors.