Oscilloscope Probes
probe with lead for single-ended measurements connected to ground.
See Also: Oscilloscopes, Analog Oscilloscopes, Digital Storage Oscilloscopes
-
product
SP500X , 500 MHz, ±300 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
783629-01
The SP500X, or Multi-Contact Isoprobe IV - 10:1, is a standard passive probe with fixed 10x attenuation for oscilloscopes that provide 1 MΩ input impedance.
-
product
Passive Oscilloscope Probes
5900 SERIES
Probe Master's new 5900 series passive oscilloscope probes are available in 400 MHz & 500 MHz bandwidths. Probes are also available with readout actuators for oscilloscopes with the readout feature. The "GOLD PROBE" has been designed specifically for use with Tektronix, Hewlett Packard and other high performance oscilloscopes. This new slim design along with a host of versatile accessories, allows you to reach the most difficult test point in today's highly complex circuitry. The gold plated Probe Tips, Sprung Hook, Ground Lead, Alligator Tip and other critical interconnect points within the Gold Probe, provide excellent contacts for probing low level analog signals and high speed digital data. Unlike most "off shore" commodity probes, Probe Master guarantees quality and continuing domestic support for our "Made in America" Gold Probe.The probe body is made of high impact ABS. Soft molded strain reliefs at all stress points assure long cable life. In short it has been designed to offer you high performance coupled with high quality.
-
product
250 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP017-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
÷10, 500 MHz, 10 MΩ, Passive Probe (Total of 1 Per Channel)
PP008-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
500 MHz Active Differential Probe
AP033
Fully Integrated: With the ProBus™ interface, the AP033 becomes an integral part of the oscilloscope. The probe sensitivity and offset can be controlled from the oscilloscope front panel, the probe front panel, or by using remote control commands (GPIB or RS-232). Sensitivity, offset, input capacitance, and common mode voltage range are displayed on the oscilloscope screen. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
product
DMM Terminal Test Lead
U1580A
The Keysight U1580A test leads are compatible with the U1600A Series handheld digital oscilloscope probes and test leads. These test leads are used for the DMM terminal on the oscilloscopes.
-
product
Passive Probe, 10:1, 500 MHz, 1.5 M
10073D
The Keysight 10073D passive probe is our most rugged 500 MHz probe. With a 10:1 attenuation ratio and high 2.2 M ohm input impedance, it is ideal as a general purpose, high bandwidth passive probe for the Keysight 300 MHz - 1 GHz 6000 series, 7000, 8000 and 9000 Series oscilloscopes. The probe identification feature automatically configures the oscilloscope for the probe attenuation.
-
product
CC05120X, 120 MHz, 5 Arms Current Oscilloscope Probe
786847-01
The CC05120X, or Hioki CT6701, is a clamp-on current probe that offers a wide DC to 120 MHz bandwidth and 5 Arms of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP022-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
CC5002X, 2 MHz, 500 A Current Oscilloscope Probe
786848-01
The CC5002X, or Hioki 3275, is a clamp-on current probe that offers a wide DC to 2 MHz bandwidth and 500 A of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP025-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
SA1000X, 1 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784255-01
1 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe - The SA1000X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
product
CP400X, 400 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784254-01
The CP400X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 2 meters in length. The CP400X attaches to BNC connections on both the signal input and instrument sides.
-
product
T3DSO Passive Probe, 350 MHz, 10X, 10 MOhm, 300V/600V
T3PP350A
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
Passive Probes
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a /10 attenuation and feature a high input resistance of 10 MOhm. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400 V, some as high as 600 V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
Passive Probe
PP011-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
WiFi Oscilloscope Probe
IkaScope
IkaScope is a wireless oscilloscope probe. It fits perfectly in your hand and works with any connected screen, like a laptop, a tablet or smartphone. Thanks to ProbeClick® technology, IkaScope knows when to measure and when to hold. IkaScope transfers measured signals over high speed wifi connection. 200 MSa/S Sampling rate. 30 MHz Bandwidth. 80 Vpp Input range. AC/DC Coupling. 4000 ptsMemory. 200 FPS Max. refresh rate.
-
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP026-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
10:1 500 MHz 10 MOhms Passive Probe
PP005A
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MO. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
Scope Probes
3900 Series
Now Probe Master offers a rugged, heavy duty oscilloscope probe at low prices. This probe features a snap-on rotating ground lead, and a heavy duty fixed tip. The switchable model allows for quick finger tip change between 1X, 10X and reference ground. The probe body is made of high impact ABS. Soft molded strain reliefs at all stress points assure long cable life. In short it has been designed to offer you high performance coupled with high quality at a low cost. Accessories include Sprung Hook, 6" Ground Lead and Trimmer Tool.
-
product
Power Integrity Analyzer Reference Solution
The power integrity analyzer reference solution is a hardware-based solution with the Keysight Infiniium S-Series 10-Bit ADC oscilloscope and probes, including the N7020A power rail probe that lets you see the true AC power noise on your DC power line and supports up to +/- 24 V offset and the N2820A high-sensitivity current probe that can measure down to 50 uA.
-
product
Oscilloscopes And Probes
An oscilloscope is quite possibly the most used piece of test equipment on an engineer’s bench. They are used by electrical engineers or anyone else wishing to measure electrical characteristics of electronic devices. However, you need more than just an oscilloscope to complete your job - you also need one or more oscilloscope probes to make accurate measurements.
-
product
AC/DC Current Probe, 100 MHz, 15A
N2893A
The Keysight N2893A is a 100 MHz bandwidth, active current probe for InfiniiVision and Infiniium oscilloscopes. The probe features flat bandwidth (DC-100MHz), low noise(<2.5 mA rms) and low circuit insertion loss. Auto demagnetization (degauss) and calibration removes any residual magnetism and unwanted DC offset in the probe. The probe is powered directly by the InfiniiVision and Infiniium Autoprobe interface, eliminating the need for an additional power supply.
-
product
CC0550X, 50 MHz, 5 Arms Current Oscilloscope Probe
786846-01
The CC0550X, or Hioki CT6700, is a clamp-on current probe that offers a wide DC to 50 MHz bandwidth and 5 Arms of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor … controllers. The probe requires an external power supply.
-
product
High-Voltage Differential Probe, 100 MHz
N2790A
Use the N2790A 100-MHz high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2790A probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to 1,400 V of differential voltage and 1,000 V of common mode voltage.
-
product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP023-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
500 MHz, 1.0 pF Active Differential Probe
ZD500
With the ProBus interface, the ZD500, 1000, and 1500 becomes an integral part of the oscilloscope. All probe gain and offset controls are transparent to the user, making it easier to probe the circuit without concern for which gain setting to choose. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
product
Oscilloscope Probes and Accessories
Teledyne LeCroy has a wide variety of world class probes and amplifiers to complement its product line. From the ZS high impedance active probes to the DH Series Differential High-bandwidth Probes which offers bandwidths up to 30 GHz, Teledyne LeCroy probes and probe accessories provide optimum mechanical connections for signal measurement.
-
product
200 MHz, 3.5 pF, 1 MOhm Active Differential probe
ZD200
With the ProBus interface, the ZD200 becomes an integral part of the oscilloscope. The probe sensitivity and offset are automatically optimized based on the oscilloscope gain settings, so control is transparent to the user. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
product
250 MHz Passive Probe for WaveSurfer3000, 10:1, 10 MOhm
PP019-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.





























