Oscilloscope Probes
probe with lead for single-ended measurements connected to ground.
See Also: Oscilloscopes, Analog Oscilloscopes, Digital Storage Oscilloscopes
-
product
Passive Oscilloscope Probes
5900 SERIES
Probe Master's new 5900 series passive oscilloscope probes are available in 400 MHz & 500 MHz bandwidths. Probes are also available with readout actuators for oscilloscopes with the readout feature. The "GOLD PROBE" has been designed specifically for use with Tektronix, Hewlett Packard and other high performance oscilloscopes. This new slim design along with a host of versatile accessories, allows you to reach the most difficult test point in today's highly complex circuitry. The gold plated Probe Tips, Sprung Hook, Ground Lead, Alligator Tip and other critical interconnect points within the Gold Probe, provide excellent contacts for probing low level analog signals and high speed digital data. Unlike most "off shore" commodity probes, Probe Master guarantees quality and continuing domestic support for our "Made in America" Gold Probe.The probe body is made of high impact ABS. Soft molded strain reliefs at all stress points assure long cable life. In short it has been designed to offer you high performance coupled with high quality.
-
product
Oscilloscope Probes
Connections to the ground of Oscilloscope Probes with the mini PCM Parrot Clip provide improved accessibility , reliability and accuracy. Ground clips for the oscilloscope probe were usually alligator clips but they have poor accessibility in narrow places due to the large jaws.
-
product
Low Voltage Differential Oscilloscope Probes
Differential signaling used in high speed serial standards requires very accurate characterization. The industry-leading bandwidth and signal fidelity found in a Tektronix low voltage differential oscilloscope probe ensures that you see every possible detail. Tektronix offers TriMode™ architecture which streamlines measurement acquisition by enabling you to make differential, single-ended, and common mode measurements with a single connection!
-
product
Oscilloscope Probes and Accessories
Teledyne LeCroy has a wide variety of world class probes and amplifiers to complement its product line. From the ZS high impedance active probes to the DH Series Differential High-bandwidth Probes which offers bandwidths up to 30 GHz, Teledyne LeCroy probes and probe accessories provide optimum mechanical connections for signal measurement.
-
product
SA1500X, 1.5 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784256-01
The SA1500X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
product
2.92mm to ProLink Adapter with Probe Power and Communication Pass Through
L2.92A-PLINK
The Teledyne LeCroy LabMaster 10 Zi oscilloscope utilizes precision 2.92mm input connectors to achieve up to 36GHz of input bandwidth. But some applications may require the use of lower-bandwidth probes for performance and cost reasons.The L2.92A-PLINK adapter converts the 2.92mm interface to a ProLink interface. This brings the benefits of a wider selection of probes to the LabMaster 10 Zi such as Dx10/Dx20/Dx00A-AT 4-6 GHz differential probes and DH Series 8 to 20 GHz differential probes using the ProLink oscilloscope probe connection. Full probe power and control is provided through a built-in LEMO interface.
-
product
250 MHz Passive Probe for WaveSurfer3000, 10:1, 10 MOhm
PP019-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP026-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
DC-to-60MHz 1:10 Oscilloscope Probe Kit (HP-9060 Or HP-3060)
PRB-HP-9060
Up to 60MHz, Includes a handy storage pouch and includes an IC test-hook adapter for the probe., The BNC connector rotates to avoid cable tangle or kink., Cable length is 1.4 meters.
-
product
Passive Probes
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a /10 attenuation and feature a high input resistance of 10 MOhm. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400 V, some as high as 600 V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
Oscilloscope Probe
Oscilloscope Probes can conduct signals up to 2.5 GHz, 300 V, or 500 Arms, even in extreme environments. They offer fixed attenuation of 10X or 100X or switchable attenuation between 1X and 10X. Oscilloscope Probes are offered in several types, including single-ended and differential, active and passive, voltage and current.
-
product
500 MHz, 1.0 pF Active Differential Probe
ZD500
With the ProBus interface, the ZD500, 1000, and 1500 becomes an integral part of the oscilloscope. All probe gain and offset controls are transparent to the user, making it easier to probe the circuit without concern for which gain setting to choose. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP024-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
1.5 GHz, 1.0 pF Active Differential probe
ZD1500
With the ProBus interface, the ZD500, 1000, and 1500 becomes an integral part of the oscilloscope. All probe gain and offset controls are transparent to the user, making it easier to probe the circuit without concern for which gain setting to choose. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
product
SA2500X, 2.5 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784257-01
The SA2500X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
product
SA1000X, 1 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784255-01
1 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe - The SA1000X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
product
DDR4 BGA Interposers, DDR4 DRAM X16 Packages
N2115A
The N2115A DDR4 BGA Interposers are soldered in between the DRAM and PC board or DIMM raw card where the DRAM would normally be soldered. They are designed with the PCB or DIMM foot print on the bottom side and the DRAM footprint on the top side. The signals from the memory controller chip and DRAM are then passed directly to the top side of the BGA probe adapter where they can be accessed with the oscilloscope probes.
-
product
DC-to-250MHz, X1/x10 Probe Kit (HP-3250i), Isolated BNC
PRB-HP-3250i
Oscilloscope Probe 1:1-1:10 - HP-3250i250 MHz bandwidth, rated 600 V.The Oscilloscope Probe 1:1-1:10 - HP-3250i is a 1:1-1:10 selectable passive high impedance oscilloscope probe with 250 MHz bandwidth (1:10) designed and calibrated for use on oscilloscopes having an input impedance of 1 MOhm shunted by 20 pF. However, it may be compensated for use with an oscilloscope having an input capacitance of 10 to 30 pF.
-
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP025-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP023-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Digital Oscilloscopes
Fujian Lilliput Optoelectronics Technology Co., Ltd.
We are one of the leading and professional digital oscilloscopes manufacturers and suppliers in China. Thanks to our highly qualified experts and advanced technology, we are also one of the world's leading brands. Welcome to buy the quality, cheap and durable dso, oscope, digital storage oscilloscope, oscilloscope probe, scope probe in stock from us. Check the quotation with us now.
-
product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP021-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
CP500X, 500 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784253-01
The CP500X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 1 meter in length. The CP500X attaches to BNC connections on both the signal input and instrument sides.
-
product
Passive Probe, 10:1, 200 MHz, 2-Pack
N2140A
The Keysight N2140A is an extremely low-cost passive probe that provides a switchable 10:1 / 1:1 attenuation and up to 200 MHz bandwidth. It features a high input resistance of 10 MΩ (switchable to 1 MΩ) to address a wide range of measurement needs with low probe loading. The probe can be adjusted for both low-frequency compensation and high-frequency compensation. For the best measurements, you should compensate your probe to match its characteristics to the oscilloscope. This probe is compatible with Keysight InfiniiVision Series oscilloscopes with 1 MΩ input.
-
product
SP500X , 500 MHz, ±300 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
783629-01
The SP500X, or Multi-Contact Isoprobe IV - 10:1, is a standard passive probe with fixed 10x attenuation for oscilloscopes that provide 1 MΩ input impedance.
-
product
Differential Voltage Probes
DP150/DP200pro
The DP differential isolation probes are an important accessory for any laboratory involved in power electronics and high voltage systems. These probes allow isolated and floating measurements with any oscilloscope or data recorder, whilst the oscilloscope can remain grounded. Using a DP150 or DP200pro probe, differential and floating measurements can be made on a variety of ac power systems like 230V/110V ac input power supplies, chopped and switching power supplies, thyristor controllers, variable speed motor drives (PWM signals), motor inrush current and measurement across current shunts. The isolated input is made via two 4mm/banana safety sockets. The BNC output allows easy connection to an oscilloscope. The DP probes can be powered from a 9V battery or external power supply.
-
product
Isolated Hall Effect Current Sensors
Isolated Hall Effect current sensors provide accurate high bandwidth current sensing. Vektrex offers models to 320A. For use, the 50-ohm voltage output is connected directly to an oscilloscope or data acquisition system. VCS sensors are magnetically isolated like clamp-on oscilloscope probes. With secure cable attachment, repeatability is ensured.
-
product
T3DSO Passive Probe, 350 MHz, 10X, 10 MOhm, 300V/600V
T3PP350A
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
Probes And Accessories
Choose from a broad portfolio of Tektronix probes and accessories, all perfectly matched to our industry-leading oscilloscopes. With over 100 choices available, select the oscilloscope probe you need for your specific testing application. Download our Probe Selector Guide here.
-
product
10:1, 10 Mohm, 300 MHz Passive Probe
PP016
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.





























