Pickering Interfaces Ltd.
The SPDT Power Relay Module consists of 48 single pole changeover relays controlled by a PXI/CompactPCI interface. It is suitable for applications were conventional reed-relay based switching modules do not have sufficient voltage rating or current carrying capacity. All 48 contacts are electrically isolated from each other and are capable of switching resistive and inductive loads up to 2000VA at 240V AC. The module is built on a single width 6U PXI module and the interface is via a standard PXI/CompactPCI backplane. Connection to the switching contacts is via three 50-pin D-type male connectors mounted on the front panel. These are machined contact types with 7.5A current carrying capacity.
-
Power 1500 Series -
Quantifi Photonics Inc.
The Power 1500 Series analog power meter brings cost-effective test and measurement. The Power 1500 provides logarithmic analog output as well as a digital optical power meter for applications that require real-time feedback.
-
ADLINK Technology Inc.
Software framework services and drivers fully support PXI-2 and PXI-6 software specifications
-
Pickering Interfaces Ltd.
Ideal for switching signals carried as differential signals where a controlled differential impedance is required
-
40-665A-001 -
Pickering Interfaces Ltd.
Model 40-665A-001 is a 18-Channel 1-Pole Power Multiplexer, suitable for switching inductive/capacitive loads up to 10A at 250VAC. It is available with a choice of 1-pole (10A) or 2-pole (8A versions).
-
Pickering Interfaces Ltd.
All of our fault insertion matrices feature a breakout arrangement that allows faults to be attached to the sensor lines via the Y axis. This includes the breaking of a connection or the adding of a series defect – all of which can simulate connectivity problems in the system. The three pin breakout versions allow the connection to be swapped for a “bad” sensor simulation.
-
40-320A-101 -
Pickering Interfaces Ltd.
The 40-320A-101 is a single 24-channel MUX and is part of our 40-310/320A range of High Voltage Switching Modules which will hot switch up to 750V peak and cold switch up to 1000V peak in either general purpose relay (40-310) or multiplexer (40-320A) configurations.
-
Pickering Interfaces Ltd.
Pickering's Switch Simulator Modules are designed for automotive test applications. These modules simulate the operation of automotive switches where dirty contacts or leaking current can be expected from switch contamination. They allow automotive I/O devices to be tested for correct operation under adverse conditions.
-
40-518A-002 -
Pickering Interfaces Ltd.
The 40-518A-002 is a 16x8 2-pole medium density matrix module and is designed for switching medium voltage/power signals in test applications where reed relays do not have sufficient rating. They are also suitable for telecoms applications where send and return signals need to be switched simultaneously.
-
Pickering Interfaces Ltd.
The matrix module is based on our proven BRIC format and can be specified as a 4 or 8 slot module. The module can be fitted with a combination of Resource Distributor and Bus Matrix Input daughter cards as required by the user. The maximum configuration is six Bus Matrix and two Resource Distributor cards fitted in a BRIC8 module.
-
40-655-002 -
Pickering Interfaces Ltd.
This multiplexer, specifically designed for switching POTS, ISDN or xDSL telephony signals, contains seven separate 4-channel multiplexers, 2-pole switching and is suitable for switching signals to 220VDC/125VAC. The module can be configured in many additional multiplexer switching formats, for example 56-channel 1-pole, 28-channel 2-pole, etc. It also can be either factory configured or later re-configured by the user at any time to form a different multiplexer function.
-
40-139-102 -
Pickering Interfaces Ltd.
The 40-139 2A Relay Series is suitable for applications requiring medium power switching with high density.Featuring 2A current capacity and voltages to 300VDC/250VAC it is useful for cost critical applications.
-
40-617A-021 -
Pickering Interfaces Ltd.
The 40-617 18-Bank, 3-Channel, 1-Pole Multiplexer Module is part of our range of reed-relay based switching solutions. The Module consists of 18 electrically isolated banks of multiplexers controlled by a PXI/PCI interface. Each bank is a 1 to 3 multiplexer and operates with break-before-make action when a new channel is selected. Any Individual multiplexer bank can have a channel set by itself, alternatively, multiple banks can have channels selected simultaneously.
-
40-611A-002 -
Pickering Interfaces Ltd.
The 40-611A-002 79-Channel, 2-Pole MUX is part of our range of Very High Density 2 Amp multiplexer modules. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-519A-002 -
Pickering Interfaces Ltd.
The 40-519A-002 is a 32x4 2-pole medium density matrix module and is designed for switching medium voltage/power signals in test applications where reed relays do not have sufficient rating. They are also suitable for telecoms applications where send and return signals need to be switched simultaneously.