High Power Generators
-
product
High-Performance Autoranging DC Power Module, 20V, 50A, 500W
N6755A
The Keysight N6755A is a 500 W high-performance, autoranging DC power module that provides low noise, high accuracy and programming speeds that are up to 10 to 50 times faster than other programmable power supplies. Optional high-speed test extension offers an oscilloscope-like digitizer that increases measurement accuracy when viewing high-speed transient or pulse events within the device-under-test (DUT).
-
product
Power Supply, 40 V, 85 A, 3400 W
N8736A
Keysight basic DC power supplies offer essential features for a tight budget. The Keysight N8736A is a 40V, 85A, 3300W single output power supply in a small 2U package. It offers flexible AC input options, analog / resistance control of output voltage and current as well as parallel and series connection of multiple supplies to achieve more output current or voltage respectively.
-
product
SPA General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
product
Power Supply Series
NGP800
The R&S®NGP800 DC power supply series, comprising five models with 400 W or 800 W, provides maximum power at a variety of operating points. The two or four 200 W outputs can each supply up to 64 V or up to 20 A. Electrically equivalent and galvanically isolated outputs can be wired in series or parallel for up to 250 V or 80 A.
-
product
DC/DC Power Supply
ISM-DC-AT512-P
The ISM-DC-AT512-P is a dual output, DC/DC power supply designed for small form factor embedded systems. It features a very wide voltage input range from 10 to 50 volts DC. This allows the unit to operate with 12, 24, or 48 volt battery or distributed DC power systems. It opens up a wide array of applications including transportation, Mil/COTS, security, solar-powered, and telecommunications.
-
product
200MHZ, 2.4 GSa/S, 20 Mpts, 2 Channel, 20 Vpp Function/Arbitrary Waveform Generator
T3AFG200
Teledyne Test Tools T3AFG5 and T3AFG10 series Function/Arbitrary Waveform Generators are a new family of low cost, high performance, single channel Function / Arbitrary waveform generators offering a high level of functionality and an excellent specification at a very competitive price point.
-
product
Pyramid, 3-Sided Chisel 30°, Alternate 0.78 (22.00) - 3.70 (105.00) General Purpose Probe
HPA-0T-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
product
10 MHz – 6 GHz USB Power Sensor
U2001A
U2001A USB power sensor enable fast, simple setup by providing plug-and-play USB connectivity and by eliminating the need for a separate power meter.
-
product
PXI/PXIe Arbitrary Generator Family
PXA(e)72xx
The arbitrary waveform generators of the PXA72xx family feature 16-bit resolution at a maximum sample rate of 200 ms per second. Furthermore, the devices can directly output voltages up to 30 V (or ±15 V).
-
product
Advanced Power System - Dynamic DC Power Supply, 40 V, 50 A, 2000 W
N7972A
The N7900 Series dynamic DC power supplies are designed for automated test equipment (ATE) applications where high-speed dynamic sourcing and measurement is needed.
-
product
PXI-5421, 43 MHz Bandwidth, 16-Bit PXI Waveform Generator
779176-01
43 MHz Bandwidth, 16-Bit PXI Waveform Generator—The PXI‑5421 is a 43 MHz arbitrary waveform generator capable of generating user-defined, arbitrary waveforms and standard functions including sine, square, triangle, and ramp. This arbitrary waveform generator can generate signals from -6 V to +6 V and uses direct digital synthesis (DDS) to precisely generate waveforms. The PXI‑5421 also features advanced synchronization and data streaming capabilities.
-
product
P2664 General Purpose Probes
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
product
Alternate 1.00 (28.00) - 2.00 (57.00) General Purpose Probe
P2663G-1R2S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
product
Industrial AC Power Supply PS2 Form Factor, 350W
APS-935XA-EPS12
- Power (typical): 350W- Current Type: EPS12- AC Voltage Input Range: 110 - 220 VAC (±10%)
-
product
Alternate 2.52 (71.00) - 6.50 (184.00) General Purpose Probe
EPA-3L5-1
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
E-Series Peak and Average Power Sensor, 50 MHz to 6 GHz
E9321A
The E9321A power sensor has a 300 kHz video bandwidth and is ideal for time-gated peak, average and peak-to-average ratio power measurements on TDMA wireless formats such as NADC, GSM and EDGE.
-
product
Flat, Alternate 0.78 (22.00) - 3.70 (105.00) General Purpose Probe
HPA-0F-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
product
Alternate 0.50 (14.00) - 2.50 (71.00) General Purpose Probe
P2662BG-2V2S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
product
Bidirectional DC Power Supply
62000D
Chroma 62000D programmable bidirectional DC power supplies provide both power source and load characteristics. These two quadrant power supplies allow power from the DUT to be converted back to the utility grid and so are ideal for testing renewable energy power systems such as PV, storage, and EV inverters as well as a wide range of bidirectional power conditioning system (PCS) and may also be used as a battery simulator.
-
product
Ultra High 4.18 (119.00) 11.70 (332.00) General Purpose Probe
EPA-3G-2
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Advanced Power System - Dynamic DC Power Supply, 9 V, 200 A, 2000 W
N7970A
The N7900 Series dynamic DC power supplies are designed for automated test equipment (ATE) applications where high-speed dynamic sourcing and measurement is needed.
-
product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1T
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-9
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
product
A-S General Purpose Probes
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 230Overall Length (mm): 5.84Rec. Mounting Hole Size (mil): 38Rec. Mounting Hole Size (mm): 0.97Recommended Drill Size: #62 or 0.97 mm
-
product
Ultra High 4.09 (116.00) - 10.00 (283.00) General Purpose Probe
EPA-2C40-2
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Micro Power, Contact, ITA, Double Male
610143104
(Available preloaded x2 in 510181102 Micro Power, ITA, Insert)
-
product
Ultra High 4.09 (116.00) - 10.00 (283.00) General Purpose Probe
EPA-2G30-2
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
P-Series Wideband Power Sensor, 50 MHz to 40 GHz
N1922A
Peak, peak-to-average ratio, average power, rise time, fall time, maximum power, minimum power, and statistical data of wideband signals.
-
product
10 MHz To 6 GHz LAN Wide Dynamic Range Average Power Sensor
L2051XA
Frequency range of 10 MHz – 6 GHzLAN connectivity with a wide dynamic range of -70 to +26 dBm for small signal measurementsFast real-time measurement of 50,000 readings/secReal-time measurement with zero dead time to ensure every single continuous pulse is measuredAverage mode time-selectivity function allows full dynamic range for average and time selectivity average power measurementsInternal zero and automatic calibration saves time and reduces measurement uncertaintyA BenchVue software license (BV0007B) is now included with your instrument. BenchVue makes it simple to connect, control instruments, and automate test sequences
-
product
Alternate 6.00 (17.00) - 2.50 (71.00) General Purpose Probe
P2662AG-1R2S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03