Filter Results By:

Products

Applications

Manufacturers

Thermal

The radiation of heat.

See Also: Energy, Chemical, Electrical, Nuclear, Electromagnetic, Thermal Shock, Thermal Test, Infrared


Showing results: 721 - 735 of 1176 items found.

  • 6 Slot VPX PCIe Gen2 Chassis

    Desert Gecko - PCI EmbeddedComputer Systems

    The 6 slot conduction cooled chassis can dissipate 120W in a non-moving air environment. The fin design and wall thickness was designed and analyzed with Flowmetrics software and designed for minimum delta T offset in an average thermal load application. The design was then verified in real life enviromental chamber experiments with a sealed chassis using our 3U heat simulator modules. Data available upon request.

  • NeuroSensory Analyzer

    TSA-II - Medoc-Web

    TSA thermal stimulator test procedure The test procedure itself is similar to that employed in such routine tests as eye and hearing examinations, where patients are asked to respond to visual or auditory stimuli. Sensory testing is performed by applying the TSA-II thermode on the patient's skin to heat or cool the skin. Patients respond to the temperature stimuli by pushing a button, and the sensory threshold is recorded and automatically compared to an age-matched normative data.

  • MEMSIC 2125 Dual-axis Accelerometer

    28017 - Parallax Inc.

    The MEMSIC 2125 is a low cost, dual-axis thermal accelerometer capable of measuring tilt, acceleration, rotation, and vibration with a range of ±3 g. For integration into existing applications, the MEMSIC 2125 is electrically compatible with other popular accelerometers. MEMSIC provides the 2125 in a surface-mount format. Parallax mounts the circuit on a small PCB, providing all I/O connections so it can easily be inserted on a breadboard or through-hole prototype area.

  • Thermal/Mechanical Testing

    Accolade Engineering Solutions

    As new products employ advanced materials and processes, the need to measure and characterize those material properties becomes increasingly important. DSC is used to measure heat flow in to or out of a material. Some DSC applications include measurement of melting temperature, polymorphic transitions, crystallization temperature, thermal stability, heat of fusion and degree of cure. TMA is used to measure dimensional changes of a material as a function of temperature.

  • GCxGC Time-of-Flight Mass Spectrometer

    PEGASUS® BT 4D - Leco Corp.

    The Pegasus BT 4D offers enhanced sensitivity by coupling our benchtop Pegasus BT with our high performance GCxGC thermal modulation system. This combination gives the Pegasus BT 4D the ability to interrogate challenging samples where the best sensitivity is needed. Unique and powerful software and hardware features simplify quantitation, while also dramatically making GCxGC easy to use and understand.

  • Datapaq Solar Tracker System

    Fluke Process Instruments

    The SolarPaq® Thermal Profiling Systems from Fluke Process Instruments are designed specifically for solar photovoltaic (PV) manufacturing including applications like contact firing, contact drying, anti-reflection coating for the solar cell, lamination and other thin film processes. These systems, consisting of user-friendly Insight™ software, Datapaq® Q18 data loggers, stainless steel thermal barriers, thermocouples with PTFE or mineral insulation and accessories, provide users with the tools needed to gather accurate, repeatable results for process optimization, maximize cell efficiency and throughput, and more.

  • Semiconductor Package Wind Tunnel

    WT-100 - Thermal Engineering Associates, Inc.

    The WT-100 Forced Convection (Moving Air) Wind Tunnel is designed in accordance with the EIA/JEDEC JESD51-6 standard for thermal characterization of semiconductor packages and devices. The vertical design minimizes laboratory floor space requiements. Air is drawn in at the bottom and exhausts at the top. The test section is large enough to accommodate the largest JEDEC and SEMI thermal test boards. Air velocity can be adjusted over the range of 0.5 to 5 m/s; air velocity is monitored with an included hot-wire anemometer connected to a digital display. A Type-T thermocouple is mounted in the test section for monitoring the moving air temperature.

  • Test House Services

    TS Space Systems

    At TS-Space Systems we have over 30 years experience in designing, building and operating vacuum systems for space simulation and materials testing. We have three in-house thermal vacuum chambers which are configurable for a range of temperatures for either monitored vacuum bakeout or thermal vacuum cycling. We design, build and operate these systems in-house which means we are more flexible than most test houses and are happy to modify feedthroughs, manufacture additional support equipment and even change the operation of the chambers, where possible, in order to accomodate customer requirements.

  • Sensors Test Cells

    Integrated MEMS - SPEA S.p.A.

    The best technical performance, cost optimization, one-shot factory integration.A single unit integrates the modules for the handling, contacting and complete testing of MEMS devices, including the physical stimulus for functional test, and the tri-temp thermal conditioning.

  • Facility Fault Diagnosis System And Safety Management System

    Scien Co., Ltd.

    A system for diagnosing failures of rotating machinery such as turbines, motors, pumps, fans, and compressors, which are major facilities in nuclear power, hydropower, thermal power plants, petrochemical plants, shipbuilding, and aviation, through displacement sensors.

  • Infrared Thermometer

    DITH 120 - Desco

    Infrared Thermometer is also known as laser thermometerInfrared thermometer is a thermometer which infers temperature from a portion of the thermal radiation sometimes called blackbody radiation emitted by the object being measured.Laser is used to help aim the thermometer or non-contact thermometers or temperature guns, to describe the device's ability to measure temperature from a distance. By knowing the amount of infrared energy emitted by the object and its emissivity, the object's temperature can often be determined. Infrared thermometers are a subset of devices known as "thermal radiation thermometers".The design essentially consists of a lens to focus the infrared thermal radiation on to a detector, which converts the radiant power to an electrical signal that can be displayed in units of temperature after being compensated for ambient temperature. This permits temperature measurement from a distance without contact with the object to be measured. A non-contact infrared thermometer is useful for measuring temperature under circumstances where thermocouples or other probe-type sensors cannot be used or do not produce accurate data for a variety of reasons.

  • Differential Scanning Calorimeters

    TA Instruments

    Differential Scanning Calorimeters (DSC) measure temperatures and heat flows associated with thermal transitions in a material. Common usage includes investigation, selection, comparison and end-use performance evaluation of materials in research, quality control and production applications. Properties measured by TA Instruments’ DSC techniques include glass transitions, “cold” crystallization, phase changes, melting, crystallization, product stability, cure / cure kinetics, and oxidative stability.

  • Dynamic Vapor Sorption Analyzer

    IGAsorp-CT - Hiden Isochema Ltd

    The IGAsorp-CT is a fully automated dynamic vapor sorption analyzer for the measurement of water and organic solvent isotherms and kinetics on a wide range of materials. Operating at temperatures from 5 to 85 °C and humidity values from 0 to 98 %RH, the IGAsorp-CT offers the widest combined range of any DVS analyzer. An optional internal heater allows fully programmable pre-heating and thermal desorption measurements to 350 °C.

  • Power Supplies

    Entes Elektronik

    Universal Input Voltage 85-265 VAC 110-350 VDC: available (available) Contact output: none (none)Parallel/Series Connection: available (available) LED Indicator: available (available)Adjustable Output Voltage: none (none) High/Low Supply Voltage Protection: available (available) Overload Protection: available (available) Thermal Protection:available (available) DIN 3 Enclosure: available (available) DIN 4 Enclosure: none (none)

  • 10-Zone SMT Reflow Oven

    CR10000 - Manncorp

    10 fully controlled upper and lower convection heating zones allow the CR10000 SMT reflow oven to provide you with a thermal accuracy of ±1˚C. Manncorp’s low-velocity, low-turbulence air flow options produce an even ΔT of ±2°C across PCB assemblies out to 22” (570 mm) wide edge-to-edge backed by throughput that can still keep pace with your high-volume production needs.

Get Help