Showing results: 691 - 705 of 1632 items found.
-
40-880B-001 -
Pickering Interfaces Ltd.
The 40-880B-001 (PXI) and 42-880B-001 (PXIe) are dual SPDT 50Ω RF switches with 8GHz bandwidth. The 40/42-880B range has automatic termination of unused signals and are available as a dual switch in 1 slot, a quad switch in a two slots or hex and octal switches in three slots.
-
40-297A-141 -
Pickering Interfaces Ltd.
The 40-297A-141 (PXI) and the 42-297A-141 (PXIe) are 3-channel programmable resistors with a range of 2.5 Ω to 201 kΩ, 0.25 Ω Resolution. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
40-297A-131 -
Pickering Interfaces Ltd.
The 40-297A-131 (PXI) and the 42-297A-131 (PXIe) are 4-channel programmable resistors with a range of 2 Ω to 13.6 kΩ, 0.25 Ω Resolution. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
42-880B-001 -
Pickering Interfaces Ltd.
The 40-880B-001 (PXI) and 42-880B-001 (PXIe) are dual SPDT 50Ω RF switches with 8GHz bandwidth. The 40/42-880B range has automatic termination of unused signals and are available as a dual switch in 1 slot, a quad switch in a two slots or hex and octal switches in three slots.
-
42-880B-002 -
Pickering Interfaces Ltd.
The 40-880B-002 (PXI) and 42-880B-002 (PXIe) are quad SPDT 50Ω RF switches with 8GHz bandwidth. The 40/42-880B range has automatic termination of unused signals and are available as a dual switch in 1 slot, a quad switch in two slots or hex and octal switches in three slots.
-
40-782B-542 -
Pickering Interfaces Ltd.
The 40-782B-542 (PXI) and 42-782B-542 (PXIe) dual transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 40GHz. Connections are made via front panel mounted high quality SMA-2.9 coaxial connectors.
-
40-782B-522 -
Pickering Interfaces Ltd.
The 40-782B-522 (PXI) and 42-782B-522 (PXIe) dual transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 18GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
40-782B-532 -
Pickering Interfaces Ltd.
The 40-782B-532 (PXI) and 42-782B-532 (PXIe) dual transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 26.5GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
40-788-021-E -
Pickering Interfaces Ltd.
The 40-788-021-E (PXI) and 42-788-021-E (PXIe) are single failsafe SP8T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-021-E -
Pickering Interfaces Ltd.
The 40-788-021-E (PXI) and 42-788-021-E (PXIe) are single failsafe SP8T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-041-E -
Pickering Interfaces Ltd.
The 40-788-041-E (PXI) and 42-788-041-E (PXIe) are single failsafe SP8T 26.5 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-041-E -
Pickering Interfaces Ltd.
The 40-788-041-E (PXI) and 42-788-041-E (PXIe) are single failsafe SP8T 26.5 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Pickering Interfaces Ltd.
The 40-788-121-E (PXI) and 42-788-121-E (PXIe) are single failsafe SP10T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-131-E -
Pickering Interfaces Ltd.
The 40-788-131-E (PXI) and 42-788-131-E (PXIe) are single failsafe SP10T 22 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-221-E -
Pickering Interfaces Ltd.
The 40-788-221-E (PXI) and 42-788-221-E (PXIe) are single failsafe SP12T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.