Showing results: 61 - 75 of 111 items found.
-
Energie Check Junior -
IKS Photovoltaik GmbH
Hot on the trail of energy guzzlers: the measuring device case offers the ideal equipment for projects in schools. The ideal set of equipment for projects in schools on the subject of saving energy, atmospheric environment, water consumption, lighting and energy requirements of electrical devices. The measuring devices are stored clearly laid-out in a special case and are always fully to hand.
-
PMS-200M -
Focused Photonics Inc.
The PMS-200M particle multi-channel sampler accepts closed-loop response control technology to sample multiple gaseous and particulate samples simultaneously in the atmosphere. The PMS-200M can monitor meteorological parameters such as atmospheric humidity, pressure, temperature and wind speed in real time. The PMS-200M is configured with 4 sampling channels, which can be extended to 8 channels through stream and timing multiplexing.
-
Sigma Tek, Inc.
These airspeed indicators have unrestrained movements.These instruments are actuated by ram air and ambient atmospheric pressure obtained from the aircraft pitot and static pressure systems. A moveable pointer and a fixed dial indicate airspeed with the zero index at the 12 o??lock position. Temperature compensation is internal and there is no external zero adjustment. Pointer damping is internally adjustable.
-
Sigma Tek, Inc.
These airspeed indicators have restrained movements.These instruments are actuated by ram air and ambient atmospheric pressure obtained from the aircraft pitot and static pressure systems. A moveable pointer and a fixed dial indicate airspeed with the zero index at the 12 o’clock position. Temperature compensation is internal and there is no external zero adjustment. Pointer damping is internally adjustable.
-
Ion Science, Ltd.
Portable Gas Detectors, classed as a type of Personal Protective Equipment (PPE), are designed to keep personnel safe from atmospheric gas hazards and allow mobile testing of locations before they are entered. These handheld devices are essential in many areas where gas hazards could occur because they are continuously monitoring at close range to the operator, while stationary and moving.
-
OBS-ONE IRLAM Unit -
HORIBA, Ltd.
The OBS-ONE IRLAM unit is an on-board emissions measurement system for analyzing the NH3/N2O under real-world driving conditions and supports our customer’s future regulatory development.The IRLAM unit combines with the GAS unit and the PN unit to measure the specified exhaust gas components, along with the exhaust gas flow rate, the GPS position, and the atmospheric conditions (temperature, humidity, pressure).
-
T7511-4 -
COMET SYSTEM, s.r.o.
Web Sensor with relative humidity and temperature probe on the cable. Built-in atmospheric pressure sensor.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
T7511 -
COMET SYSTEM, s.r.o.
Web Sensor with relative humidity and temperature probe on the cable. Built-in atmospheric pressure sensor.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
T7510 -
COMET SYSTEM, s.r.o.
Web Sensor with built-in temperature, relative humidity and atmospheric pressure sensors. High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
T7511-2 -
COMET SYSTEM, s.r.o.
Web Sensor with relative humidity and temperature probe on the cable. Built-in atmospheric pressure sensor.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
VRS-20 -
Valeport Ltd,
Versatile and simple to install, the VRS-20 has been developed by Valeport to work seamlessly with the TideMaster Tide Display/Logger and other third party data loggers using RS232, RS485 and SDI-12 communication. Non-contact technology removes the installation, corrosion & fouling issues of submerged sensors, while simplifying datum control. Accuracy and performance are unaffected by changes in water density and atmospheric conditions.
-
200M -
Edgetech Instruments
The Model 200M is a complete instrument for the measurement of Atmospheric Dew Point, Ambient Temperature, % Relative Humidity, or other Psychrometric Variables. It employs the very reliable optical chilled mirror sensing technique which provides a primary measurement of dew point, and is traceable to NIST. The Model 200M is ideally suited for installations requiring continuous, automatic, and unattended measurement of humidity over a very wide range.
-
NUL-221 -
Neulog
This logger sensor measures atmospheric barometric pressure and can display data in four common units. kPa kilopascal atm atmospheres in Hg inches of mercury mm Hg millimeters of mercuryThe sensor also offers an option to display the measured pressure values in terms of altitude (in meters).
-
ZET 7123 -
ZETLAB Company
Digital meteorological sensor ZET 7123 is a measuring unit with two in-built sensors, one of which is used for measuring relative humidity and temperature, and the other one – for atmospheric pressure measuring. ZET 7123 meteorological sensor measuring unit converts signal from the sensing elements to temperature, humidity, and pressure values. The obtained values are transmitted via CAN interface and displayed in the measurement units set by the user.
-
Scientific Research Corp. STI Division
SRC has developed a family of products used to test radar systems during development and to train after system implementation. Our product provides realistic signals at RF, IF, and at baseband that simulate multiple targets, jamming, atmospheric effects, and clutter. In addition to meeting U.S. needs, these radar environment simulators have been sold to customers in Spain, The Netherlands, and other countries to support key radar developments.