PIN Diode Switches
-
product
PXI 4 Slot BRIC 72x16 2A 1-Pole Matrix
40-598-003
The 40-598 PXI Matrix BRIC provides a range of high density matrix modules able to switch up to 2 Amps or 100VDC/70VAC. The 40-598 BRIC modules are available in 2, 4 or 8-slot PXI sizes to suit most high performance PXI Matrix requirements, constructed using high quality electromechanical relays for high switching confidence.
-
product
PXI Solid State Very High Density Matrix
40-501-001
The 40-501 is a very high density matrix using solid state switching configured as a 64x4 1-pole matrix in a single slot 3U PXI module. It is ideal for applications requiring fast operation and a long service life with frequent switch operations at high voltages. Since the design is based on solid state relays the matrix has no wear out mechanism.
-
product
LXI Scalable Matrix - 8Amp 8x10 Matrix Plugin Module
65-239-202
The scalable matrix chassis offers you a solution that can be easily re-configured by the insertion and removal of sub-cards. It is purchased as an empty chassis with a quantity of sub-cards required for a particular matrix size. As your requirements evolve, additional cards can be easily fitted. When new cards are added, the control software automatically detects the new configuration.
-
product
PXI 12-Slot BRIC Matrix, 210x12 1-Pole (5 sub-cards)
40-558-121-210X12
The 40-558-121-210x12 matrix is part of a range of BRIC ultra-high-density large PXI matrices are available in 2, 4, 8 or 12-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
product
PXI 4 Slot BRIC 184x8 1-Pole Dual Analog Bus (4 sub-cards)
40-560A-021-184X8-M
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high-performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
product
High 1.80 (51.00) - 12.60 (357.00) Switch Probe
TSP138-FK400-3
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 138Test Center (mm): 3.50Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,760Overall Length (mm): 44.70Switch Point (mil): 67Switch Point (mm): 1.70
-
product
PXI 12-Slot BRIC Matrix, 286x8 2-Pole (13 sub-cards)
40-562B-322-286X8
The 40-562B-322-286X8 is a high density BRIC12 matrix module with a size of 286x8 with 2-pole switching. It is part of a range of BRIC matrices available in 2, 4, 8 or 12-slot formats to suit high performance PXI matrix requirements and is constructed using instrumentation quality reed relays.
-
product
PXI High Density Matrix Module, 32x4, 1-Pole, 2A, 60W
40-528B-001
PThe 40-528B is a 128 crosspoint PXI matrix with single pole switching and a configuration of 32x4 using electromechanical relays with 2 A current handling. The module is designed for switching medium voltage and power signals, typical applications include signal routing in ATE and data acquisition systems.
-
product
LXI 2.4GHz 50ohm 32x8 Matrix
60-771-001
The 60-771 is a family of integrated RF matrices suitable for use up to 2.4GHz in a 50 ohm transmission line system. The matrix design permits any single Y input to be connected to any single X input, permitting the concurrent connection of 8 RF paths. All signal paths are bi-directional permitting any connection to be used as an input or an output.
-
product
PXI 4-slot BRIC Matrix, 128x8, 1 pole (2 Sub-cards)
40-558-401-128x8
The 40-558-401-128x8 matrix is part of a range of BRIC ultra-high-density large PXI matrices are available in 2, 4, 8 or 12-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
product
PXI 8-Slot BRIC Matrix, 2A 1-Pole 225x4, 3 Sub-cards
40-568A-103
The 40-568A-103 is a PXI 1-pole 225x4 matrix in BRIC8 format and is part of a range of high density matrix modules able to switch up to 2 A or 300VDC/250VAC. The 40-568A BRIC modules are available in 2, 4 or 8-slot PXI sizes to suit most high performance PXI Matrix requirements, constructed using high quality electromechanical relays for high switching confidence.
-
product
PXI 12-Slot BRIC Matrix, 460x4, 1-Pole (5 sub-cards)
40-560B-321-460X4
The 40-560B-321-460x4 is an ultra high density matrix module and is part of our range PXI BRIC matrices. They are available in 2, 4, 8 or 12-slot sizes to suit high performance PXI switching requirements and is constructed using instrumentation quality reed relays
-
product
SWB-2813, 4x21, 1 A, 2-Wire Reed Matrix Module for SwitchBlock
781420-13
4x21, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2813 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
product
PXI 2-Slot BRIC Matrix, 96x16, 1 Pole (3 Sub-cards)
40-558-201-96x16
The 40-558-201-96x16 matrix is part of a range of BRIC ultra-high-density large PXI matrices are available in 2, 4, 8 or 12-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
product
PXI 2 Slot BRIC 45x16 2-pole (3 sub-cards)
40-561A-222-45X16
The 40-561A-222-45x16 is part of a range of high-density PXI BRIC matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays.
-
product
PXI 12-Slot BRIC Matrix, 143x16 1-Pole (13 sub-cards)
40-562B-321-143X16
The 40-562B-321-143X16 is a high density BRIC12 matrix module with a size of 143x16 with 1-pole switching. It is part of a range of BRIC matrices available in 2, 4, 8 or 12-slot formats to suit high performance PXI matrix requirements and is constructed using instrumentation quality reed relays.
-
product
PXI 8 Slot BRIC 44x8 1-Pole (2 sub-cards)
40-562A-121-44X8
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
product
Modular VXI Switch Card Carrier
1260-100
The 1260-100 Switch Carrier accommodates up to six plug-in switch cards, providing optimum switching solutions while reducing the ATE size requirements.
-
product
PXI 12-Slot BRIC Matrix, 60x32 1-Pole (12 sub-cards)
40-562B-321-60X32
The 40-562B-321-60X32 is a high density BRIC12 matrix module with a size of 60x32 with 1-pole switching. It is part of a range of BRIC matrices available in 2, 4, 8 or 12-slot formats to suit high performance PXI matrix requirements and is constructed using instrumentation quality reed relays.
-
product
PXI 12-Slot BRIC Matrix, 512x8 1-Pole (8 sub-cards)
40-558-121-512X8
The 40-558-121-512x8 matrix is part of a range of BRIC ultra-high-density large PXI matrices are available in 2, 4, 8 or 12-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
product
SWB-2814, 8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock
781420-14
8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2814 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
product
PXI 8-slot BRIC Matrix, 96x16, 1 pole (3 Sub-cards)
40-558-801-96x16
The 40-558-801-96x16 matrix is part of a range of BRIC ultra-high-density large PXI matrices are available in 2, 4, 8 or 12-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
product
Modular VXI Switch Card Carrier
1260-101
The 1260-101 Switch Carrier accommodates two plug-in switch cards in a single slot VXI module.
-
product
Single 24x8 1-Pole High-Density PXI Matrix Module
40-520-202
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
product
PXI 8-slot BRIC Matrix, 924x6, 1 Pole (11 Sub-cards)
40-558-801-924x6
The 40-558-801-924x6 matrix is part of a range of BRIC ultra-high-density large PXI matrices are available in 2, 4, 8 or 12-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
product
PXI 12-Slot BRIC Matrix, 90x32 1-Pole (18 sub-cards)
40-562B-321-90X32
The 40-562B-321-90X32 is a high density BRIC12 matrix module with a size of 90x32 with 1-pole switching. It is part of a range of BRIC matrices available in 2, 4, 8 or 12-slot formats to suit high performance PXI matrix requirements and is constructed using instrumentation quality reed relays.
-
product
LXI HighDensity 128x16 2A Matrix with BIRST
60-554-024
A high-density single pole matrix module capable of switching up to 300VDC/250VAC, 2A (60W max). The use of high-quality electro-mechanical relays offers high switching confidence for signal routing in large ATE systems.
-
product
PXI 8-slot BRIC Matrix, 84x12, 1 pole (2 Sub-cards)
40-558-801-84x12
The 40-558-801-84x12 matrix is part of a range of BRIC ultra-high-density large PXI matrices are available in 2, 4, 8 or 12-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
product
PXI/PXIe RF Matrix, 16x2, 300 MHz, 50 Ω MS-M Multiway With Loop-thru
42-728A-002-L
The 40-728A-002-L (PXI) and 42-728A-002-L (PXIe) are 16x2 50 Ω RF matrices with MS-M Multiway connectors and Y-axis loop-thru. The 4x-727A/728A/729A range are high density RF matrix modules suitable for switching up to 300 MHz in 50 Ω or 100 MHz in 75 Ω. They are available in 50 Ω or 75 Ω versions with SMB connectors or in 50 Ω versions with a multiway connector.
-
product
PXI BRIC8 FIBO Matrix Dual 120x4 3pin brkout
40-592A-106
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.