Millimeter Wave
extremely High Frequency in the range of 30 to 300 gigahertz.
See Also: Wave, Extremely High Frequency, Long-Wave IR, Lightwave, Shear Wave, Sub-mm Wave, Microwave, Wavelet, Continuous Wave, Submillimeter Wave, Sine Wave, Shock wave, mmWave, MW
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T1-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Broad Band Amplifiers
Broad band amplifiers (A.K.A. wide band) from Fairview Microwave provide amplification for radio frequencies in broadband. Our broad band amplifiers applications include: military / defense, test instrumentation, EW/ECM, radar, satcom, telecom, microwave radio and various industrial RF, microwave and millimeter wave applications. Fairview broad band amplifiers have a maximum frequency as high as 18 GHz depending on the amp configuration.
-
product
Ultra High 4.09 (116.00) - 10.00 (283.00) General Purpose Probe
EPA-2L-2
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Ultra High 1.77 (50.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-25H-10
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
High-speed Interconnect Analyzer, 4-port, S-par @40 GHz, <1 mm Res., 4 phase matched cables
WAVEPULSER-40iX
High-speed Interconnect Analyzer, 4-port, S-par @40 GHz, <1 mm Res., 4 phase matched cables.
-
product
Free Room Temperature Bore magnet with Insertable DR
Room Temperature magnet bore 50 mm sample space in DR Suitable for use with Leiden DR type CF200, CF450, CF650 or CF1000 DR
-
product
Coaxial Open, 2.4 mm (m)
85141A
The Keysight 85141A coaxial open is used for establishing measurement planes for known reflection phase and magnitude in 50-ohm coaxial systems. It has a 2.4 mm male connector.
-
product
Handheld Water Quality Meters
LAQUA PH220
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers) - 0.01 pH resolution- Offset and average slope display - Automatic / manual temperature compensation and temperature calibration function- ORP calibration option- °C & °F temperature readings- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached- Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrode and calibration solutions in carrying case- 3 years meter warranty
-
product
Oscilloscope 40 GHz, 4 Channels, 1.85 mm Inputs
UXR0404B
XR0404B Infiniium UXR-Series is the 40 GHz, 4 channel, 1.85 mm input, Infiniium UXR-Series real-time oscilloscope.
-
product
Differential Pressure Transmitter
616D
The Series 616D Differential Pressure Transmitter senses the pressure of air and compatible gases and sends a standard 4-20 mA output signal. The 616D housing is specifically designed to mount on a 35 mm DIN rail in a panel
-
product
Industrial Flex ATX AC Power Supply for Mini-ITX Chassis, 250W
APS-925XU (80Plus)
- Power (typical): 250W- AC Voltage Input Range: Universal- Certifications: UL/cUL/TUV/CCC- Dimensions: 150 x 81.5 x 40.6 (mm)
-
product
SINE FBI Charts
There are two SINE Sinusoidal arrays designed for FBI applications: the SINE M-13-60-S-RM and the SINE M-13-60-FBI Kit.The SINE M-13-60-S-RM was designed jointly by the Federal Bureau of Investigation, of Washington DC, and MITRE, of Bedford MA. The primary function of this Target is for computing Modulation Transfer Function (MTF) evaluation in live scanner fingerprint systems for conformance to Integrated Automated Fingerprint Identification Systems (AFIS) image quality requirements. The array is on reflective material measuring 16mm x 16mm with sinusoidal arrays ranging in frequency from 1.0 to 10.0 cycles per mm; with nominal modulation of the sinusoidal areas at 60%. The top and bottom rows are density scales, from 0.20 to 1.20 densities.The SINE M-13-60-FBI Kit consist of two individual components, the SINE M-13-60-1X-RM and the RR1-N-RM Ronchi Ruling grating.
-
product
Cable Continuity Tester, USB 3.0 Mini, Network, 21.01 mm, 45.01 mm, 47.02 mm
72-9210
The 72-9210 is a Mini Cable Tester for USB 3.0 (A/B, A/A, A/micro B) cable. Mini cable tester fits easily in your pocket or tool box.
-
product
PCX Multimeter Test Leads Clip
- The PCX Parrot Clip model is aimed to be used mainly for multimeter test leads.- When is hand held, is a handy device giving comfort to the operator.- The PCX Parrot Clip model is effective for direct point, hands-on measurements.- It has a length of about 130 mm so that it points with the metal tip places rather crowded with electronic components.- The PCX provides also reliable hands-free connections.- Even that is rather long the PCX model is not heavy, and therefore the weight of the probe is not affecting and forcing the connection.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1I35-4-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Alternate 2.50 (71.00) - 5.80 (164.00) General Purpose Probe
P2665G-2W2S
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1L18-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
ICT/FCT-Fixtures Max UUT 370 × 300 mm (wxd)
CK-2 Large (Hold-Down Gate) / 230158
The series of In-Circuit testers that are Teradyne for the 228x and TestStation are dedicated tools that rely on the tester hardware for diagnostics and test pattern delivery. The integration of the stand-alone BTS with the Teradyne ICT can enhance the system’s capability. In other words, it can provide access to additional tools. It provides the user with a common platform and portability of test patterns from stand-alone to ICT and later on to functional test and depot test stations.
-
product
Mode-Conditioned Light Sources
Thorlabs' Mode-Conditioned Light Sources are fiber-coupled LED sources that have an output with a flat-top profile in the far field. Common applications include the testing of multimode fused fiber components as well as verification of modal behavior in fiber-based setups. Standard fiber-coupled LED sources can have a range of output profiles that are usually not uniform and vary from source to source. This can be dependent on emitter orientation, alignment with fiber tip, and connector assembly. These mode-conditioned sources have been engineered to distribute light evenly into all transverse modes, resulting in an equilibrium modal distribution at the output. The front panel includes an adjustment knob to control the power and an output port that accepts 2.2 mm wide-key FC/PC connectors. A DS15 15 V power supply with a location-specific plug is included with each device.
-
product
Spectroscopic Reflectometer
– Antireflective coating (ARC) on textured (poly-) crystalline silicon solar cellMeasurement– Thickness, Reflectivity, n&kWavelength– 420 – 950 nm (1.3-3.0 eV) : expandableAccuracy (thickness measurement on specular sample)– 104.5 nm for 104.8 nm SiO₂on c-Si* Accuracy can be dependent on the quality of filmThickness range– 10 nm ~ 20 mm (depend on sample)Data acquisition time– < 1 sBeam spot size– ~ 50 mmFocusing of beam– Manual (optional auto-focus)Sample stage– Manual X-Y stage (specify sample size and travel distance)(optional automatic X-Y stage for mapping)
-
product
Handheld Water Quality Meters
LAQUA PC210
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater - Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
product
Premium 4.49 (127.00) - 12.00 (340.00) High Performance Lead Free Probe
LFRE-25I35-12
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2F
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
High 1.73 (49.00) - 8.00 (227.00) High Performance Bias Ball Probe
POGO-1T1-8
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Bias Ball Probe
POGO-1T1-7
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
product
Changeable Cassette
230352/1 – CMK-03
Linear click system with ball bearings, using gas springs.10 mm ESD-proof top cover with aluminum reinforcement bars.Steel base cabinet with detachable aluminum back and bottom panels.Detachable interchangeable case system with an 8 mm spring-loaded probe protection cover.Base cabinet fitted with a telescopic guide rail and catch.
-
product
CAN AD MiniModules
CSM’s AD MiniModules of the AD CAN MM (MiniModule)-Series offer a wide range of applications for measuring analogue signals (voltage, current, pressure, flow rate, etc.).
-
product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes
-
product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 3.5 Mm, 2 Port
85093D
The Keysight 85093D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.





























