Cesium Standards
A primary frequency standard in which electronic transitions between the two hyperfine ground states of cesium-133 atoms control the output frequency.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1A-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-F180-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
Standard Directional Gyroscopes
4000B-series
-
The 4000B is our standard air-driven directional gyro. As the aircraft turns left or right, gears on the sensing unit and dial shaft translate this rotation into rotation of the instrument’s vertical dial. Left turns produce clockwise dial rotation and right turns produce counter-clockwise rotation. The gyro is controlled by a heading selector knob located on the lower left of the instrument. Pressing and turning the knob first disengages the dial shaft and then resets the dial to a new heading, which results in a new course indication. Releasing the selector knob re-engages the dial shaft. The on-course position of the pointer is always at the top of the azimuth circle (0° on the dial with the aircraft headed north).
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4H
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T1-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, Type-N, 50 Ohm
85032F
-
The Keysight 85032F calibration kit contains precision 50 ohm type-N standards used to calibrate Keysight network analyzers. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 9 GHz.
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72J-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Standard 3.00 (85.00) - 6.00 (170.00) Non Replaceable General Purpose Probe
G-S-R
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1L24-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Gain Horn Antennas
-
Linear polarized Broadband Horn Antenna (Brass with Plastic mounting body) for Receive and Transmit Applications.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25J-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-H180-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Sematech Analysis and SEMI Standards Analysis
-
Rocky Mountain Laboratories, Inc.
Rocky Mountain Laboratories, Inc. provides SEMI Standards analyses that conform to the following SEMATECH and SEMI Standards for testing of passivated 316L stainless steel components being considered for installation into a high-purity gas distribution system:SEMASPEC #90120401B-STD (SEM Analysis)SEMASPEC #90120402B-STD (EDS Analysis)SEMASPEC #90120403B-STD (XPS Analysis)SEMASPEC #91060573B-STD (Auger (AES) Analysis)SEMI F60-0306 (based on F60-0301) (XPS Analysis)SEMI F72-1102 (Auger (AES) Analysis)
-
Product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50U
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4B
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Standard Digital Isolators
-
Analog Devices’ digital isolators enable designers to implement robust solutions with our magnetically isolated iCoupler products with the flexibility of up to 6 channels. Products meet stringent safety standards including the ability to isolate IS-IS with our intrinsically safe certified digital isolators which enable designs in hazardous areas. And automotive certified versions are also available. Utilizing the iCoupler® and isoPower® technologies, these isolation solutions enable designs without the constraints found in optocouplers.
-
Product
Standard Voltage 9 Pin D-Type Cables - Calibration Cables for Pickering Products
-
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 9-pin D-type calibration port connector.
-
Product
Additional Products: Standard Voltage 50 Pin D-Type Connectors
-
The connectors below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Transmitter
Tipix 2200
-
The TIPIX 2200 is a transmitter purposely designed for deep Induced Polarisation or Resistivity sounding investigations. This transmitter is generally used together with V-Fullwavers or Elrec Pro receivers. This entry-level instrument has been designed for an ease of use and for a good productivity together with a strong protection against misuse. This very robust device has proven to be reliable even in very cold weather (up to -40°C) or in wet environment. It is able to inject up to 2200W in the soil and to inject up to 13A, so that it is suitable, even on conductive soils, to measure resistivity and IP at medium range depths. It is powered by standard generator.
-
Product
Absolute Contamination Standards (ACS)
-
The Absolute Contamination Standard (ACS) is used to calibrate instruments which size and detect particles on the surface of bare silicon wafers. Use ACS to characterize particles, before particles characterize products.
-
Product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2550-6
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1I15-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.09 (31.00) - 4.50 (128.00) Long Travel Bead Probe
BPLT-1HF-4.5
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
Product
Windows Embedded Standard
-
Componentized operating system lets you create a custom operating system image to deliver the necessary functionality for the device. Provide device users with a unique and powerful branded experience.
-
Product
Conformance Calibration Standard Test Card for GS1-128 Symbol Verifiers
AI-CCS-128-E Rev B
-
This test card is ideal for testing of verifiers, scanners, and other GS1-128 barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″