Product
CC3050X, 50 MHz, 30 Arms Current Oscilloscope Probe
785561-01
High Current Probe
The CC3050X, or Hioki 3273-50, is a clamp-on current probe that offers a wide DC to 50 MHz bandwidth and 30 Arms of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor … controllers. The probe requires an external power supply.
-
Product
HDMI High Definition Cable Tester
PHCT85
-
Use The HDMI Cable Tester To Troubleshoot Your HDMI Cables Before You Install ThemEvery Pin Connection Of Standard Type "A" HDMI Connectors,Instantly Indicates Continuity Status Using 9 LED Indicators.All Connections Are HDMI Female TypeRequires Standard 9V Battery Not IncludedDimensions:4.06'x 3.57'x 1'Sold as : Unit
-
Product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
High Frequency Probe
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53
-
Product
Ultra High Frequency Vibrometer
UHF-120
-
Polytec?s New UHF-120 Vibrometer Laser-Doppler Vibrometers (LDV) can characterize the out-of-plane vibrations at ultra-high frequencies. Polytec?s UHF-120 extends the vibration frequency bandwidthup to 600 MHz.
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L
High Frequency Probe
Current Rating (Amps): 5Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 1.90Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
High Definition MWIR Science-Grade Camera
FLIR X8580™
-
The FLIR X8580 midwave IR camera is designed for scientists and engineers who need to capture detailed imagery of high-speed events, perform custom radiometric measurements, or detect points of failure in composites, solar cells, and electronics. This thermal imaging camera combines 1280 × 1024 HD resolution with fast frame rates and integration times, allowing researchers to record stop motion on fast-moving subjects or rapid temperature changes—whether in the lab or on the test range. With a four-position motorized filter wheel and support for FLIR motorized focus lenses, the X8580 will provide higher quality recordings, save time, and mitigate frustration in dynamic acquisition environments.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
Brute High Current Probe
P4301-1R
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Ultra High Productivity Solution
Universal Encoder 3
-
*Compatibility - UE3 is 100% compatible with the Force 3 system. Boards can be used as spares for the Force 3 system*Reference Flexibility - Multiple Digital and Analog References*GPS Discipline - GPS timing and assures starts on even sample boundaries for all continuous recording systems*Multiple Radio Support - UE3 can connect simultaneously to 4 High Speed TDMA radios. These multiple high speed radios assure reliable and efficient communication to all of the vibrator units used in High Production Vibroseis Mode*Digital Radio Support - UE3 supports the latest Digital Radios*Analog Radio Support - UE3 also supports legacy analog radios*Ethernet Radios Support - The UE3 includes support for low-power VHF-Ethernet radios. These radios have good speed and work well in many applications*Digital Radio Sims - Digital Radio Similarities are now available for UE3 and Force 3 or VibPro HD vibrator controllers*External USB Port - Use USB thumb drive to offload data from remotely operated UE3 units
-
Product
CC05120X, 120 MHz, 5 Arms Current Oscilloscope Probe
786847-01
High Current Probe
The CC05120X, or Hioki CT6701, is a clamp-on current probe that offers a wide DC to 120 MHz bandwidth and 5 Arms of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
Product
WaveRunner High Definition Oscilloscopes
WaveRunner 8000HD Series
-
Providing 12 bits all the time, more channels than any other oscilloscope, and long memory without tradeoffs – the WaveRunner 8000HD 8 channel oscilloscope captures every detail.
-
Product
Ultra High Density 4mm Reed Relays
120-1-A-12/1
Reed Relay
Single Pole Reed Relays0.5 Amp switchingVery high packing densityStacking on 4mm x 4mm pitch1 Form A12 V Coil
-
Product
High Definition LWIR Science-Grade Camera
FLIR X8580 SLS™
-
The FLIR X8580 SLS is a high-speed, high definition longwave IR camera designed for scientists and engineers who need to capture detailed imagery of fast events, perform custom radiometric measurements, or detect points of failure in composites, solar cells, and electronics. This thermal imaging camera combines 1280 × 1024 resolution from the SLS detector with high-speed frame rates to offer shorter snapshot speeds and wider temperature bands for crisp stop motion imagery of high-speed events. With a four-position motorized filter wheel and support for FLIR motorized focus lenses, the X8580 SLS will provide high quality recordings, save time, and mitigate frustration in dynamic acquisition environments.
-
Product
SHC68-C68-RDIO2, 68-Pin VHDCI Male to 68-Pin VHDCI Male, 80 MHz, Shielded Digital Cable, 2m
156166-02
High Speed Digital Cable
SHC68-C68-RDIO2 Shielded R Series High Speed Digital Male VHDCI Cable, 2m
-
Product
Ultra Clean, High Concentration, High Flow Ozone Generator
SEMOZON® AX8415
-
The SEMOZON® AX8415 is the most innovative and versatile ozone generator developed by MKS. Ultra clean, high concentration, high flow ozone is produced by this generator's novel architecture and patented cell design, converting oxygen to >400 g/Nm3 of high concentration ozone for leading-edge applications in the semiconductor, flat panel display and photovoltaic industries.
-
Product
Ultra High Density 4mm Reed Relays
120-1-A-3/2
Reed Relay
Single Pole Reed Relays0.5 Amp switchingVery high packing densityStacking on 4mm x 4mm pitch1 Form A3 V Coil
-
Product
PXI Ultra High Density 64x4 2-Pole Matrix
40-533B-022
Matrix Switch Module
The 40-533B ultra high density matrix module is configured as 64x4 or 64x2 and is available in a choice of 1-pole and 2-pole reed relay formats. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by daisy chaining the common signals from multiple PXI modules.
-
Product
Ultra High Speed Pick & Place
MC889
-
The MC889 is specially designed for the fast and highly precise loading of large batch sizes. This pick and place machine is equipped with an optical centering, "Vision on the Fly" system that guarantees the best possible measurement of SMD components (such as 0201, SOIC, PLCC, BGA, µBGA, CSP & QFP, as well as odd-shaped components) while completing placement at rates of 20,000 CPH.
-
Product
HDO4000A High Definition Oscilloscopes
HDO4000A Series
Oscilloscope
HDO4000A oscilloscopes have 4 analog input channels, 12-bit resolution using Teledyne LeCroy’s HD4096 high definition technology, up to 1 GHz of bandwidth and a compact form factor with a large 12.1” multi-touch display. They are ideal for debug and troubleshooting of power electronics designs, digital power management or power integrity analysis, automotive electronics systems, and deeply embedded or mechatronic designs.
-
Product
High Definition Oscilloscope, 350 MHz Bandwidth, 4 Input Channels, 10 GS/s
HDO4034A
Oscilloscope
350 MHz, 10 GS/s, 4 Ch, 12.5 Mpts/Ch 12-bit HD Oscilloscope with 12.1" WXGA Color Display.
-
Product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-1I40-10
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Bias Ball Probe
POGO-1L-10-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Ultra High 3.83 (109.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-72I40-10
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Ultra High Power Precision Shunt Resistor
UHPS
-
*Max. current limit 707A*Excellent short term stability*Low temperature coefficient of resistance (T.C.R.)*High current sensing & reference resistors in laboratories*Change - discharge test equipment for high capacity batteries*Current sources & laboratory power supplies
-
Product
Ultra High 3.38 (96.00) - 10.00 (283.00) Bead Probe
BTP-72HC-10
Bead Target Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Ultra High Density 4mm Reed Relays
122-1-A-5/2
Reed Relay
Single Pole Reed Relays0.5 Amp switchingVery high packing densityStacking on 4mm x 4mm pitch1 Form A5 V Coil
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
Low-Cost Fixed Focus Miniature High Definition Camera
L3C-HD
-
The Teledyne Bowtech L3C-HD is a low cost fixed focus miniature high definition camera. Its housing is manufactured with high quality titanium, rated to either 1,000m, 4,000m or 6,000m operating depth.The camera is fitted with a fixed focus wide angle lens. This provides a 67° diagonal angle of view in water. The Sapphire window is highly scratch resistant and 99.8% opitcally pure. The camera features built-in reverse polarity and surge protection.
-
Product
Ultra High 1.77 (50.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-25Z-10
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
High Frequency Probe
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes