Showing results: 46 - 60 of 150 items found.
-
E1834J -
Keysight Technologies
The E1834J is a 67% beam splitter in a high performance horizontal mount that offer the high pointing stability for Keysight laser interferometer measurement system. The 8 flexure feet are designed for stable beam pointing.
-
10769A -
Keysight Technologies
The 10769A is ideal for use in laser measurement and calibration applications. In the calibration of slant bed lathes, for example, the beam steering mirror deflects the beam from the laser head upward, through the interferometer, along the lathe's cross slide. One or more mirrors can also create a path from a laser head to an interferometer located in an otherwise inaccessible position, as in the case of a milling machine with a table that moves in only one axis.
-
Duma Optronics LTD
The LAT (Laser Analyzing Telescope) is a powerful measuring instrument enabling direct measurement of laser beams or other light sources.The LAT will analyze and display the angular direction of incoming laser beams with resolutions down to 1 micro-radian and accuracy of 1 millidegree (~20 micro-radian).The built-in back Filter Slider allows control of the laser level impinging the detector area. Moreover, a special version will allow angle measurement of cross-like collimated targets to be examined.Results are clearly displayed by the provided software.
-
LT-PLM Series -
Laser Components IG, Inc.
The precision laser diode module of the LT-PLM series features a precise housing from which the laser beam exits at the very center. This eliminates any beam angle error. The module can be operated without safety eye wear and is therefore suitable for all sorts of alignment tasks: whether machines have to be aligned to each other. the thorn inside a turning lathe needs to be centered. Manufactured by LT Laser Tools GmbH
-
Duma Optronics LTD
Laser beams are tracing a perfect straight propagating line. A special unique instrument was developed to monitor the direction and position of this laser beam, creating a cornerstone device for alignment. Typical applicationns are mechanical straightness and alignment, calibration articulated arms, accurate positioning, and many more. To facilitate unrestricted movement of the AlignMeter family a built-in wireless system was developed.
-
10777A -
Keysight Technologies
The Keysight 10777A Optical Square, used with Keysight straightness measurement optics, adds squareness measurement capability to the Keysight5530 Laser Calibration System. The optical square measures the squareness of axes during laser calibration of a machine tool. The Keysight 10777A uses two accurately-aligned mirrors to direct an output beam at precisely 90 degrees to an input beam.
-
Phasics
Phasics wavefront sensor applies to laser beam measurement, wavefront correction through an adaptive optics loop, laser optics testing and plasma density measurement. Thus the single instrument offers true versatility to engineers and researchers in laser facility.
-
10769B -
Keysight Technologies
The Keysight 10769B Turning Mirror on Universal Mount deflects a laser beam at any angle, in either the vertical or the horizontal polarization plane of the beam. The 10769B contains the same turning mirror as the 10769A, but has a different mounting.
-
Coherent Corp.
Measure laser pulse energy over a huge range of wavelengths, repetition rates, pulse energies, and beam diameters.
-
Newport Electronics
We offer a wide range of laser beam position detectors for optical alignment including Quadrant Cell Photoreceivers, PSDs, and Thermopile Position Sensors. Please see our Beam Position Sensor Guide for more information.
-
eyeme
Shadow laser micrometer is a powerful tool for precision measurements in various applications. This device uses a laser beam to project a shadow of an object onto a receiver, allowing for accurate and non-contact measurement of distances and dimensions.
-
BeamCheck -
mks Ophir
BeamCheck is an integrated laser measurement system designed to measure critical laser beam parameters for laser-based additive manufacturing systems BeamCheck includes a CCD camera for spatial measurements and a NIST-traceable power sensor that will provide a complete analysis of the laser power density profile.
-
Duma Optronics LTD
The M2 factor wil define the beam propagation characteristics compared to ideal Gaussian beam propagation. According to ISO Standard 11146 rightfully offers the laser beam characterization as "M2 times diffraction limited beam", as such, a perfect beam will have an M2 of 1. 1 will be the best achievable value and no beam could have an M2 less than 1. Our conceptual design is based on sub-assemblies allowing to change the sensing head in the M2 device, offering multiple wavelengths heads up to 2.7 microns from deep UV (knife-edge technology) and camera based technology with built-in automatic filter wheel for adjustment. For focused beams, the same measuring head could be attached to a device for meauring highly divergent or highly convergent beams - FocusGage-BA, wherein the Laser Analyzing Electronic Autocollimator offers the capability of divergence measurement with Coming Soon M2 definition. M2Beam is the cornerstone of those measuring devices.
-
Thorlabs, Inc.
Thorlabs' M2 Measurement Systems provide self-contained, turn-key solutions for measuring M2, divergence, focus diameter, waist position, Rayleigh length and other laser beam quality metrics. Pre-configured, factory-aligned systems covering wavelength ranges between 250 nm and 2700 nm are available. Choose from among systems that have a scanning-slit beam profiler, a camera beam profiler, or no beam profiler.
-
mks Ophir
Terahertz laser power and beam profiling measurement is not a trivial task. But as anyone using or developing THz lasers knows, it is crucial to obtain accurate measurements of your laser. Ophir offers a few choices, depending on what aspect of your laser you need to measure. Read these posts for more about Terahertz measurement.