Filter Results By:

Products

Applications

Manufacturers

Showing results: 121 - 135 of 160 items found.

  • Mid-Range Gas Filter Correlation CO Analyzer

    Model N300M - Teledyne Advanced Pollution Instrumentation

    The Model N300M is a microprocessor-controlled analyzer used to determine the concentration of carbon monoxide (CO) in a sample gas. The analysis method is based on the Beer-Lambert law.The N300M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.

  • Sample Conditioner

    PCA-400 - Bacharach, Inc.

    Bacharach’s active sample conditioner is used to enhance the performance of the PCA® 400 combustion and emissions analyzer in heavy industrial and commercial settings. The PCA® 400 provides accurate readings for CO, O2 and NO with a standard probe. Bacharach also offers optional Viton™ tubing with the sample conditioner to eliminate sample dropout, ensuring accurate results in applications where NO2 and SO2 measurements are necessary. The sample conditioner removes water vapor from the stack gas sample, preventing the formation of water droplets inside the analyzer’s probe hose. Water in the sample hose could absorb a portion of the gas sample and result in lower than actual readings of NO2 and SO2. The water extracted from the gas sample is pulled out of the thermoelectric (Peltier) cooler and into a water catch pot. The dry, conditioned flue-gas sample is then passed through to the PCA® 400 for analysis, ensuring a clean, dry, accurate air sample. This also prevents water passing into the instrument and possibly damaging the sensors or other components.

  • Gas Filter Correlation CO​​​​ Analyzer

    ​Model N300 - Teledyne Advanced Pollution Instrumentation

    The Model N300 is a microprocessor-controlled analyzer based on the Beer-Lambert law that is used to determine the concentration of carbon monoxide (CO) in a sample gas.The N300 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb Infrared (IR) light. The analyzer passes the IR light beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.

  • 1 kW and 2 kW Laser-Based Floating Zone Furnace

    Laser Furnace - Quantum Design Inc.

    The 1 kW and 2 kW laser furnace for single crystal fabrication is based on a design and developed in close cooperation with the RIKEN Center for Emergent Matter Science under the leadership of Yoshio Kaneko. Both melting zones have 5 lasers each, which guarantees a high uniformity of power density in the melting zone range. The laser profile has been optimized to reduce thermal stress during the crystal growth process. In addition, the system includes an integrated temperature sensor for real-time temperature monitoring. Temperatures up to 3000 °C can be reached and therefore materials with a very high vapor pressure, a narrow temperature range of the melt, a high thermal conductivity coefficient and incongruent melts can be melted.

  • Mid-Range Gas Filter Correlation CO2 Analyzer

    Model N360M - Teledyne Advanced Pollution Instrumentation

    The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the eff​ects of ambient CO2, if necessary.

  • Gas Filter Correlation CO2 Analyzer

    ​Model N360 - Teledyne Advanced Pollution Instrumentation

    The Model N360 measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the eff​ects of ambient CO2, if necessary.

  • Walk-In Altitude Test Chamber

    ACMAS Technologies Pvt. Ltd.

    WEIBER Altitude Test Chambers combine temperature and altitude to test basic components or subassemblies designed for use in a variety of industries. With altitude test chambers, user can control the temperature environment for testing while simulating various altitudes from site level to 100,000 feet (1.12kPa)High and low Temperature Altitude Test Chamber is used to test temperature and low-pressure altitude conditions simultaneously. All models are factory tested, with an ergonomic and maintenance cum user-friendly design.These CE approved test chambers are created with multi-layered insulation with double vapor barrier is of low 'K' factor, high density and of non-hygroscopic in nature. WEIBER test chamber are made in accordance with the international standard.Standard as well as customizable models are available. Walk in models are also available.

  • Air Brake, Air Suspension & Air Powered Accessory Systems Leak Finder

    Air Brake NanoLeak Finder - Redline Detection, LLC

    “The Air Brake NanoLeak Finder™ allows technicians, for the first time ever, to test for air brake leaks and pinpoint the precise location of leaks, in minutes. The equipment is being used by OEMs to locate leaks in heavy duty trucks and equipment that would take hours with conventional methods, saving valuable service time and getting trucks back on the road fast” said Alex Parker, Executive Vice President of Redline Detection “this is a very exciting breakthrough for anyone who deals with air brake leaks.” The patent pending technology in the machine creates a signature vapor that, in conjunction with the hand-held NanoLeak™ Locator, pinpoints the precise location of air brake leaks instantly. Clear, audible and visual signals speed diagnostics and pinpointing of leaks. The equipment improves efficiency, saving valuable hours and marking a dramatic technical advance from conventional, messy, soapy water methods and ineffective listening devices.

  • Optical Spectrum Analyzer Module Specification

    CA92001B - UC Instruments, Corp.

    UCINSTRUMENTS CA92001B C band optical spectrum analyzer module is a spectral engine for Process Analytical Technology applications. The OSA module acts as a stand-alone spectral engine, imaging and measuring a wide range of vapors, liquids and solids through transmission and diffuse reflection in a rapid non-destructive process. Leveraging our proprietary Micro-Optic technology, UC INSTRUMENTS’ C band OSA module features the following characteristics: (1) compact; (2) light-weight; (3) low power consumption; and (4) wide wavelength coverage. These characteristics of UC INSTRUMENTS’ compact OSA engines are suitable for a variety of handheld, portable or bench-top OSA/spectrometer applications. Equipped with a state-of-the-art internal wavelength reference, the OSA module is capable of precisely measuring optical spectrum. Because it does not require an expensive InGaAs detector array, the compact OSA module is a cost-effective alternative to other grating-based OSA/spectrometer engines. The OSA communicates with a PC or an instrument motherboard via an USB interface. UCINSTRUMENTS’ OSA module platform can be installed or co-packaged into existing NIR OSA/spectrometers as a cost-efficient alternative to other scanning optical engines.

  • Electrostatic Discharge Testing / ESD Testing

    Keystone Compliance

    Electrostatic discharge testing, also known as ESD testing is an essential test for many product. Electrostatic discharge can cause a number of problems including but not limited to mechanical failures, coal dust explosions, fuel vapor explosions and bodily injury. ESD is the sudden transfer of electricity between to electrically charged objects. This electrostatic transfer can be caused by contact, dielectric breakdown or an electrical short. ESD testing simulates various electrostatic impacts that equipment might experience either during transit or operation. The impact of electrostatic discharge can be significant whether the ESD even is so slight that is undetectable by hearing or sight or as spectacular as electrical sparks or lightning. An electrostatic discharge test determines whether a product is in compliance with its ESD protective area and procedures. Electronics manufacturers must identify ESD-reducing measures when their products are either susceptible to ESD or likely to create ESD. These measures can include establishing electrostatic protective areas that are free of static, controlling humidity, using measures to eliminate charging such as avoiding highly charging materials and taking steps to remove static such as grounding human workers or requiring antistatic devices. An ESD test confirms that the equipment correctly operates per the test requirement and the manufacturer’s operating procedures.

  • ATEX & CID2 Anti-Explosion Certified Robust DIN-rail Fanless Embedded System With Intel® Atom® Processor E3827 (1.75 GHz)/E3845 (1.91 GHz)

    rBOX510-6COM (ATEX/C1D2) - Axiomtek Co., Ltd.

    The rBOX510-6COM(ATEX/C1D2) robust din-rail fanless embedded system is certified with ATEX and C1D2 for use in hazardous environments where ignitable concentrations of flammable gases, vapors or liquids might exist. The embedded system supports the dual-core Intel® Atom™ processor E3827 1.75GHz SoC with the onboard 4GB DDR3L system memory. The din-rail heavy-duty embedded PC adopts an IP30-rated aluminum and steel enclosure, and can perform in wide temperatures ranging from -40°C to +70°C. To prevent ESD and over-voltage, the compact embedded box PC is equipped with four isolated RS-232/422/485 ports, two isolated 10/100/1000Mbps Ethernet ports, and one isolated DIO (8-IN/8-OUT) port. One 2.5" SATA SSD, one mSATA and one CompactFlash™ socket are available for storage. More I/O features include one USB 3.0 port, one USB 2.0 port, two COM ports, and one VGA output. In addition, box PC comes equipped with a wide range 12 - 48VDC power input with a terminal block and has overvoltage and reverse protection. The box PC provides two watchdog timers and RTC battery function. Pre-installed with Linux, Windows® 8 Embedded and Windows® 7 Embedded, the embedded system provides programmers with a friendly environment for developing application software at a lower cost. For secure mounting, the rBOX510-6COM(ATEX/C1D2) can be easily installed on a DIN-rail mount or in an enclosure box.

  • Cesium Vapour Magnetometer

    ENVI Cs - Scintrex Limited

    The ENVI Cs is a continuous reading magnetometer with high sensitivity with integrated navigational GPS and a versatile design that offers the user the ability to maximize productivity.

  • Continuous Measurement With Float

    WIKA Alexander Wiegand SE & Co. KG

    Our level sensors enable the continuous detection of levels, independent of physical and chemical changes of the media such as foaming, conductivity, dielectric, pressure, vacuum, temperature, vapours, condensation, bubble formation, boiling effects and density change. Via the HART® interface, parallel measurement of interface layer and overall level is possible. The level can be displayed proportional to height or volume. Process connection, guide tube and float can be manufactured from stainless steel 1.4571, 1.4435, 1.4539, titanium or various plastics.

  • Float Switches

    WIKA Alexander Wiegand SE & Co. KG

    Float switches in (the process) industry are used for the point-based limit level detection of one or several levels. They work independently of foaming, conductivity, dielectric, pressure, vacuum, temperature, vapours, condensation, bubble formation, boiling effects and vibrations and are suitable for almost all liquid media. The switching operation is contact-free, free from wear and needs no supply voltage. The simple and proven functional principle of the float switch enables a very wide range of applications, from general industrial applications through to use in process plants or in the shipbuilding industry.

  • Gas Analysis

    Hiden Analytical Ltd.

    Measures evolved gases and vapours from thermo gravimetric analysers

Get Help