Probing Micropositioners
set a probe in x-y dimension handsfree.
-
product
Light 0.83 (24.00) - 2.00 (57.00) Bead Probe
BTP-1F-2
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25I8-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Bias Ball Probe
POGO-1I-10-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Analyzer Probes
The following probes are available for the MA51x0 and MA41x0 series analyzers. These probes are designed for low-voltage and high-speed midbus probing or probing with an interposer. The following JEDEC memory standards are widely used by these probes: DDR5 (JESD79-5), DDR4 (JESD79-4), DDR3 (JESD79-3), LPDDR5 & LPDDR5X (JESD209-5), LPDDR4 & LPDDR4X (JESD209-4), and LPDDR3 (JESD209-3).
-
product
Magnetostatic probe
BS13
Three-dimensional measurement of magnetic equationsMeasuring range 100 TResolution 0.1 TAbsolute and relative measurementsFor connection to the field meter FM10Switching between total field strength and X, Y and Z proportions is possiblePermanent recording and saving of individual points with the field meter FM10LOutstanding value for moneyDimension 132 x 40 x 25 mm
-
product
Standard 1.09 (31.00) - 4.50 (128.00) Long Travel Bead Probe
BPLT-1HL-4.5
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
product
Current Probes
Innovative DC to 5MHz "positional" current probe capable of measuring currents in PCB tracks, component legs etc. without the need to break the connection or surround the conductor.
-
product
Alternate 2.58 (73.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-25T79-6
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.50 (14.00) - 2.00 (57.00) Non Replaceable General Purpose Probe
A-A-S-C
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 310Overall Length (mm): 7.87Rec. Mounting Hole Size (mil): 31.5Rec. Mounting Hole Size (mm): 0.80Recommended Drill Size: #68 or 0.79 mm
-
product
Probes
Hygro-i Series
The Tramex Hygro-i ® relative humidity probe is the most advanced, resilient and reusable RH probe on the market today. Used in conjuntion with Tramex CMEX II and MRH III moisture meters, the Hygro-i ® relative humidity probes allow the user to perform in situ and hood type RH testing to comply with ASTM F2170 and British Standards BS 8201, 8203, 5325 for the Flooring Industry, and is ideal for use by Flood & Water Damage Restoration and Indoor Air Quality professionals.
-
product
Elevated 1.68 (4.00) - 7.00 (198.00) Bead Probe
BTP-1C-7
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
HPA General Purpose Probes
General Purpose Spring Probe contact solutions are designed for high volume testing and feature the industry-proven Pylon line. General-purpose probes are offered in both replaceable and non-replaceable options.
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25L-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Bias Ball Probe
POGO-1I35-7-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Alternate 0.66 (19.00) - 6.00 (170.00) High Performance Bias Ball Probe
POGO-62H-6
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Bias Ball Probe
POGO-1L-10-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
High Force Type Probe For PCB, K100 Series 100mil Pitch, Type L, Ø1.50mm, 230gf
K100-L150230-SKAU
K100 Series, Pitch 100mil, Tip Style L, Tip Diameter Ø1.50mm, Spring force 230gf, Steel with Gold Plating.
-
product
Current Probes
XQ13
Beijing GFUVE Electronics Co.,Ltd.
The model XQ13 ac micro amp clamp on current probe is suitable for 10A-100A cable online measurement, it belongs to high performance current sensor field.
-
product
Alternate 1.00 (28.00) - 2.00 (57.00) General Purpose Probe
P2663G-1R2S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T75
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
Alternate 2.58 (73.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-25I-6
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
High 2.90 (82.20) - 12.60 (357.00) Switch Probe
TSP100-FK180-3
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
product
Alternate 1.10 (31.18) - 7.20 (204.00) Switch Probe
TSP100-H150-2
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
product
PROBE CARD
the electrical characteristics of the individual CHIPs in WAFER that have been completed through the FAB stage during the semiconductor fabrication process
-
product
Differential probe
DP3000 Series
A “differential” probe is an active probe which has two inputs, one positive and one negative as well as a separate ground lead and it drives a single terminated 50Ω cable to transmit its output to one oscilloscope channel
-
product
SIP-90-3 Test System Interface Probe
SIP-90-3
Overall Length (mil): 700Overall Length (mm): 17.78Rec. Mounting Hole Size (mil): 55Rec. Mounting Hole Size (mm): 1.40Recommended Drill Size: #54 or 1.40 mm
-
product
Differential Probe
DP-30K
*30KVp-p, High Voltage Model .*Input Impedance 81.6MΩ//1PF *x200, x2000 Attenuator, Easy to Convert.*Separating Design(Standard No.114205)*Convenient & Durable.