Dense Wavelength Division Multiplexing
Dense Wavelength Division Multiplexing
-
Product
PXI/PXIe MEMS Optical MUX, Single 2-Channel, Multi-Mode, 62.5/125 Fiber
40-855A-212-M-HI
-
The 40/42-855A-212-M-HI is a PXI/PXIe 2-channel multiplexer with SC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI/PXIe RF Multiplexer, Quad 4-Channel, 3GHz, 50Ω, MCX
40-872A-104
-
The 40-872A-104 (PXI) and 42-872A-104 (PXIe) are 50 Ohm 4 to 1 RF multiplexers available with 4 banks in a single PXI slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP6T, 67GHz, 50Ω, SMA-1.85
40-785C-571
-
The 40-785C-571 (PXI) and 42-785C-572 (PXIe) are single SP6T 67GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI Very High Density Multiplexer, 49-Channel, 4-Pole
40-675A-002-49/4
-
The 40-675A-002-49/4 is a 49-channel, 4-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
Product
PXI/PXIe High Density 2A Multiplexer, 1-Bank, 16-Channel, 8-Pole
40-614D-018
-
The 40-614D-018 (PXI) and 42-614D-018 (PXIe) 1-bank, 16-channel, 8-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI 2 Amp MUX, Quad 8-Channel 1-Pole
40-635-108
-
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI High Density Multiplexer, 4-Bank, 16-Channel, 1-Pole, Screened
40-610A-014
-
The 40-610A-014 is a screened 4-bank, 16-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI/PXIe MEMS Optical MUX, Dual 2-Channel, Single-Mode
40-855A-122
-
The 40/42-855A-122 is a PXI/PXIe dual 2-channel multiplexer with FC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
PXI 2A Multiplexer 158-Channel 1-Pole
40-611-001
-
The 40-611 Very High Density multiplexer module is available in 158-Channel 1-Pole or 79-Channel 2-Pole configurations. Both configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
LXI Microwave Multiplexer, SP4T, 1-Bank, 26.5GHz, 50Ω, SMA
60-803-301
-
Our 60-803-302 is a 2 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 26.5GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI-2576, 64‐Channel, 2-Wire, Multibank PXI Multiplexer Switch Module
778572-76
-
64‐Channel, 2-Wire, Multibank PXI Multiplexer Switch Module —The PXI‑2576 is a multibank PXI multiplexer switch module with 16 banks of 4x1 2‑wire multiplexers. With the flexible architecture of the PXI‐2576, you can configure it in a variety of topologies that make it suitable for parallel measurement operations requiring low‐channel counts, or you can combine all multiplexer banks to form a single high‐channel‐count multiplexer featuring 64 2‑wire channels. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
Product
PXI/PXIe RF Multiplexer, Single 16-Channel, 3GHz, 75Ω, MCX
42-835A-101
-
The 40-835A-101 (PXI) and 42-835A-101 (PXIe) are single 75 Ohm 16-channel RF multiplexers in a single slot. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz. The design of the 40/42-835A minimizes the injection of noise and unwanted signals into the signal path by careful attention to the mechanical and electrical design.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 26.5GHz, 50Ω, SMA, Remote Mount
40-784B-132-E
-
The 40-784B-132-E (PXI) and 42-784B-132-E (PXIe) are dual SP4T 26.5GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI/PXIe MEMS Optical MUX, Single 2-Channel, Single-Mode, 9/125 Fiber,
40-855A-312-HI
-
The 40/42-855A-312-HI is a PXI/PXIe 2-channel multiplexer with MU connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI Very High Density MUX 5 Chan 32 Pole
40-675-002-5/32
-
The 40-675 series of very high density low cost multiplexer modules are available in a versatile range of switching configurations. The modules are supplied pre-configured in one of six multiplexer modes suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP8T, 8 GHz, 50 Ω, N-Type, Remote Mount, Failsafe
42-788-011-E
-
The 40-788-011-E (PXI) and 42-788-011-E (PXIe) are single failsafe SP8T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP4T, 40 GHz, 50 Ω, SMA-2.9, Failsafe
42-784B-141
-
The 40-784B-141 (PXI) and 42-784B-141 (PXIe) are single failsafe SP4T 40 GHz unterminated microwave multiplexers. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI/PXIe MIL-STD-1553 Multiplexer, Dual 16-Channel, 2-Pole
40-739-002
-
The 40-739-002 (PXI) and 42-739-002 (PXIe) are dual 16-channel 2-pole multiplexers designed specifically for physical layer multiplexing or demultiplexing differential signals that conform to the MIL-STD-1553 specification. The module can be supplied as a single or dual 16-channel 2-pole multiplexer with each signal pair having a controlled 78 Ohm differential impedance.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP10T, 22 GHz, 50 Ω, SMA, Failsafe
40-788-131
-
The 40-788-131 (PXI) and 42-788-131 (PXIe) are single failsafe SP10T 22 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
Product
PXI Very High Density Multiplexer, 198-Channel, 1-pole
40-670C-022-198/1
-
The 40-670C-022-198/1 is a 198-channel, 1-pole MUX and is part of a series of very high density multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
PXI/PXIe Microwave Multiplexer, Single SP6T, 26.5 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-785C-531-TE
-
The 40-785C-531-TE (PXI) and 42-785C-531-TE (PXIe) are single failsafe SP6T 26.5 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI High Density Multiplexer, 1-Bank, 128-Channel, 1-Pole
40-610A-004
-
The 40-610A-004 is a 1-bank, 128-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP6T, 40GHz, 50Ω, SMA-2.9
40-785C-541-T
-
The 40-785C-541-T (PXI) and 42-785C-541-T (PXIe) are single SP6T 40GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI 2A Multiplexer, 2-Bank, 8-Channel, 8-Pole
40-614C-013
-
This 2-bank, 8-channel, 8 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXIe-254, 6.6 GHz, 50 Ω, Solid-State, Dual 4x1 PXI RF Multiplexer Switch Module
780587-43
-
PXIe, 6.6 GHz, 50 Ω, Solid-State, Dual 4x1 PXI RF Multiplexer Switch Module—The PXIe‑2543 features high-performance solid-state relays that offer unique benefits such as unlimited relay life and fast switching time. Front-mounted SMA connectors provide easy connection to your RF devices, and the module features termination on every COM line and channel.
-
Product
PXI/PXIe MEMS Optical MUX, Triple 2-Channel, Single-Mode
40-855A-332
-
The 40/42-855A-332 is a PXI/PXIe triple 2-channel multiplexer with MU connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
PXI Dual SP6T Multiplexer 18GHz 50, SMA, Terminated
40-785B-522-T
-
The 40-785B-522-T is a dual 6-channel 18GHz terminated microwave multiplexer. The 40-785B range of multiplexers are available as a single or dual 6-channel panel mounted multiplexer with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI Dual 8 to 1 Mux 2GHz 50Ohm SMB
40-748-511
-
The 40-748 is a dual 8 to 1 RF MUX available in 50 Ohm or 75 Ohm versions occupying a single PXI slot. The module is available with SMB or SMA connectors for 50 Ohm versions or, 1.0/2.3 or Mini SMB connectors for 75 Ohm versions. Applications for the 40-748 include routing high frequency signals to and from oscilloscopes, analyzers, signal generators and synthesizers, telecoms tributary switching, video/audio switching and switching high frequency logic signals.
-
Product
PXI 2A Multiplexer, 2-Bank, 16-Channel 4-Pole
40-614-012
-
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
RF Multiplexer 3GHz, 4 to 1
40-872-004
-
The 40-872-004 is a 50 ohm 4-to-1 RF MUX available with 4 banks in a single PXI slot. Using modern RF relay technology, it features low insertion loss and low VSWR at an affordable price. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics up to frequencies of 3 GHz, with each path having a nominally equal insertion loss.