HFCT Ø 140mm -
Techimp HQ S.r.L
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
Power Monitoring and Diagnostic Technology Ltd.
PMDT is the only manufacturer to utilize all 5 types of online partial discharge sensor technology. Using multiple sensing methods ensures that PD activity is always discovered, located, and characterized. PMDT's handheld PDetector and PDStar units have more capability than the high-end diagnostic equipment of the past. The small handheld, battery powered unit can completely perform the test and analysis without the need of a PC. PDetector, PDStar, and PDiagnostic instruments feature high-resolution phase-resolved analysis of PD signals (PRPD and PRPS) in real time, so you get your test results instantly!
-
TAWF series -
Shanghai Jiuzhi Electric Co., Ltd.
TAWF series coupling capacitors are used as resonant system base load, separation of PD signals from the high voltage, measuring AC voltages and attenuating interferences from HV side (TAWF type with additional filtering inductance).
-
GTU-1200KVA/600KV -
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test,and for testing all GIS switchgears and GIS components such as insulators,insulating tension pole,GIS voltage transformer and so on,the PD test can be performed under the general environment because of the merits of encapsulation ,the PD level of our equipment can be lee than 3pC,and it can be added a HV bushing to perform the withstand voltage test at the same time.
-
GTU-800KVA/800KV -
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test,and for testing all GIS switchgears and GIS components such as insulators,insulating tension pole,GIS voltage transformer and so on,the PD test can be performed under the general environment because of the merits of encapsulation ,the PD level of our equipment can be lee than 3pC,and it can be added a HV bushing to perform the withstand voltage test at the same time.
-
Techimp HQ S.r.L
UHF Spiral antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in the monitored asset. It is a broadband antenna with a flat response which makes Spiral antenna suitable in a number of different applications. It has been optimized to operate in a frequency range typical for PD activity and it was designed to provide maximum sensitivity and high gain. Its compact and robust design (passive sensor) makes Spiral antenna the optimal sensor for direct installation on high voltage Transformers. It can be virtually applied in any electrical equipment provided that it has apertures or EM transparent surfaces. Contact our sales department for consulting.
-
2500 -
Dwyer Instruments Inc.
The Series 2500 Temperature Control provides an impressive array of features in an economical 1/4 DIN package. Features include on-off, time proportioning, proportional, PI, PD, or full PID control, programmable from the front panel, or use Self-Tune PID.
-
Yangzhou Power Electric Co., Ltd
The test system is used to do AC voltage withstand test and PD measurement for high voltage insulation products, combined electrical equipment, instrument transformers, etc.
-
Techimp HQ S.r.L
TEM antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in the monitored asset (like MV switchgears or LV and MV induction motors fed by power electronic impulses). It is a broadband antenna with a flat response which makes TEM suitable in a number of different applications. It has been optimized to operate in a frequency range typical for PD activity and it was designed to provide maximum sensitivity and high gain. Its compact and robust design (passive sensor) makes TEM the optimal sensor for direct installation on medium voltage Switchgears and motors. It can be virtually applied in any electrical equipment provided that it has apertures or EM transparent surfaces.
-
PDExpert -
Power Monitoring and Diagnostic Technology Ltd.
The PDExpert is PMDT's third level of Partial Discharge (PD) Expert Diagnostic and Location System. It is a powerful, portable, multi-channel system of impeccable design used to analyze and pinpoint PD signals coming from a power asset within centimeters while the power system is energized. The system consists of UHF, AE, HFCT and ultrasonic sensors, one advanced UHF/PD signal processing unit, one oscilloscope, filters and other accessories.The system employs ultra-high speed data acquisition and advanced digital signal processing technologies, compares the UHF, AE and HFCT signals of different frequency ranges to determine if it is PD or noise, and locates the source in power assets accurately by utilizing Acoustic-Electromagnetic Combination Location Technique, time Difference of Signals' Arrivals (TDOA), and 3D Positioning Technology.
-
PDS100 -
Doble Engineering
The Doble PDS100 Partial Discharge Surveyor is a radio frequency interference (RFI) surveying tool that is designed for use in a live substation.Without the need for outages, the PDS100 can detect partial discharge (PD) in just a few seconds making it an ideal tool for a condition based maintenance program.
-
Doble Engineering
Doble offers a complete range of PD and oil analysis tools that can be used while equipment remains in service. This non-invasive testing allows you to find early indications of deterioration giving you time to plan a course of action for further testing, maintenance or eventual replacement.
-
HPA Series -
High Voltage Inc.
HPA Series test sets perform AC withstand and PD testing (most models) on higher capacitance loads, offering up to 40 kVA and 300 kV AC
-
Power Diagnostix Systems GmbH
Power Diagnostix calibrators enjoy all the advantages of 20 years' experience in calibration services. The broad range of easy-to-use and robust units for many different applications ensures reliable PD measurements compliant to international standards, such as IEC 60270, CISPR 18-2, and NEMA 107-1987.
-
Power Monitoring and Diagnostic Technology Ltd.
PMDT Engineers are always available to review your test samples and to provide guidance to users in the field. Our PD experts have the ability to accurately analyze various types of field test data based on PRPD/PRPS spectrums, waveforms and audio files collected during a field test.