Filter Results By:

Products

Applications

Manufacturers

.NET

software framework primarily running on Microsoft Windows.


Showing results: 121 - 135 of 160 items found.

  • Temperature Input Device For FieldDAQ

    NI

    The Temperature Input Device for FieldDAQ measures up to 16 thermocouple channels. The module features cold-junction compensation and open thermocouple detection with an LED indicator per channel to identify disconnected thermocouples. Additionally, the module incorporates Time Sensitive Networking (TSN), which provides tight synchronization over a distributed network of data acquisition nodes without additional cabling or complex programming. The device also features an integrated network switch and built-in power circuitry for simple daisy chaining.The Temperature Input Device for FieldDAQ includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • ARINC 429 XMC Interface Module

    XMC-429 - Avionics Interface Technologies

    16, 32, or 64 ARINC 429 channels (up to 32 Tx & 32 Rx) - Programmable Tx channel output amplitude - Programmable high/low speed operation - Eight (8) Discrete I/O (Four (4) inputs, and four (4) outputs) - Concurrent operation of all Tx/Rx Channels at high data rates - Full error injection and detection - Data capture filtering, 100% bus recording, and physical bus replay - IRIG‐B time code encoder/decoder for data correlation - Conduction-cooling and/or conformal coating available - Designed for extended temperature operations - ANSI Application interfaces supporting C, C++, C#, and .net development - Device driver support: Windows, Linux, and VxWorks (others provided upon request)

  • Deadweight Testers & Gauges

    Chandler Engineering

    The most accurate instrument available for the measurement of pressure above a few psig is the Hydraulic Deadweight Gauge. This type of gauge operates on the principle of balancing a known mass against the force exerted by an unknown pressure on a piston of known area. When an exact balance is achieved, the unknown pressure "P" is equal to the mass "M" of the weights divided by the area "A" of the piston, according to the formula "P" = "M" / "A". In us, weights are removed or added from the piston's table, as with a double-pan balance until the piston "floats" without net vertical movement.

  • C Series Counter Input Module

    NI

    The C Series Counter Input Module features flexible, 32-bit counters. You can configure each channel to read a single pulse train or combine them to read up to four incremental encoders. You can also directly connect sensors with open-collector or push-pull outputs by using an internal, switchable pull-up resistor. Additionally, you can use the C Series Counter Input Module to perform encoder position and velocity measurements as well as to synchronize the counters with other analog, digital, and counter measurements in your chassis.The C Series Counter Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • C Series Voltage Output Module

    NI

    The C Series Voltage Output Module helps you update analog output models that feature overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. This module includes up to 16 channels. Some models include a channel-to-earth ground double isolation barrier for safety and noise immunity as well as improved signal quality, and some higher density models conserve chassis space, which leaves room for other measurement types.The C Series Voltage Output Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • MIL-STD-1553 PMC Interface Module

    PMC-1553 - Avionics Interface Technologies

    Dual redundant, single, dual, or quad stream configurationsTransformer & Direct Bus Coupling - Concurrent Bus Controller, 31 Remote Terminals, & Bus Monitor operation - Full error injection and detection - Multi-level trigger for capture and filtering - IRIG-B time code encoder/decoder - Ten high voltage (up to 30V) programmable DIO lines - Real-Time recording and physical bus replay - ANSI Application interface supporting C, C++, C#, and .NET development - Device driver support: Windows, Linux, VxWorks, & LabVIEW Real-Time (others on request) - Conduction-cooling and/or conformal coating available - Designed for extended temperature operations - 3.3v PMC (with 5V Tolerant I/O), 64-bit 33/66MHz - Rear (P14) and Front Panel Input/Output - Compatible with AIT’s Flight Simulyzer GUI Bus Analyzer Software

  • MIL-STD-1553 XMC Interface Module

    XMC-1553 - Avionics Interface Technologies

    Dual redundant, single, dual, or quad stream configurations - Transformer & Direct Bus Coupling - Concurrent Bus Controller, 31 Remote Terminals, & Bus Monitor operation - Full error injection and detection - Multi-level trigger for capture and filtering - IRIG-B time code encoder/decoder - Ten high voltage (up to 30V) programmable DIO lines - Real-Time recording and physical bus replay - ANSI Application interface supporting C, C++, C#, and .NET development - Device driver support: Windows, Linux, VxWorks, & LabVIEW Real-Time (others on request) - Conduction-cooling and/or conformal coating availableDesigned for extended temperature operations - x1 Lane PCI Express Host Interface - Rear (P14) and Front Panel Input/Output - Compatible with AIT’s Flight Simulyzer GUI Bus Analyzer Software

  • ARINC 429 PMC Interface Module

    PMC-429 - Avionics Interface Technologies

    4, 8, 16, or 32 Software Programmable Tx/Rx ChannelsProgrammable High/Low Speed Operation - Concurrent operation of all Tx/Rx Channels at high data rates - Conduction-cooling and/or conformal coating available - Designed for extended temperature operations - Rate-oriented Label Transmission - Label Selective Trigger for Capture/Filtering - IRIG-B Time Code Encoder/Decoder for Data Correlation - ANSI Application Interface supporting C++, C#, and .net DevelopmentDevice Driver Support: Windows, Linux, VxWorks, and other operating system - Compatible with AIT’s Flight Simulyzer GUI Bus Analyzer Software

  • Shoes and Wrist Strap Tester

    WST100 - Eurostat Group

    • Tester designed for checking the conformity of operators wrist strap and/or shoes to the ESD protection standard.• It is also designed to be permanent wall mounted in a production facility for daily testing of employee’s wrist straps and footwear.• Easy to operate, red and green LEDs give clear “pass” or “fail” indication• Individual tests for the wrist strap, the right and left shoe• Can register up to 60 000 different measurements• Output for interface with PC or automatic door opening system• Operates battery that can be supplemented with an AC net adaptor• Tester and calibration plug are delivered with a certificate ofcalibration

  • 12-Ch 10A-250VAC RCV Power Distribution Unit

    YAVAR438 - 6TL Engineering

    - Hardware controlled Enable Input- 12 Power relays up to 10A 250VAC/DC and 300W or 2.700VA switching power- 12 10-mOhm shunt resistors.- 6 Switched 2-Pole sense channels- Single phase isolated or 3-Phases non-isolated switching capabilities, to or from the device under test (power or load)- VPC TriPaddle 96 pins connector.- NI LabView & TestStand driver.- .NET, C/C++, VB driver.- Soft Front panel for direct interface.- CAN Control or Ethernet (with Ethernet to CAN Gateway).- Self-test module available.- Form A

  • Networked CCTV

    TCP/IP - Pontis EMC

    As most of the test sites are using a LAN, we also offer camera systems that are accessed and controlled via TCP/IPIn this case the camera or controller has an Ethernet interface that is connected to the LAN. If our video control SW is installed on a PC, You may access the camera via this SW from any location within the net work.The Audivo video control software, allows you to view up to 4 cameras on one screen. The access can be limited to special defined users.The IP access gives the tools to store screen shots for documentation on the local HDD of the PC.

  • Software Engineering Services

    Reston Software, llc

    Reston Software provides state-of-the-art, U.S.-based software development services. We can fulfill your immediate and long-term software development needs by creating new applications, supporting and enhancing existing applications, and modernizing legacy applications.We focus primarily on Microsoft technologies: .NET, WPF/XAML, Visual C++, COM/ATL, ASP.NET, Microsoft Office plug-ins.We also specialize in upgrading legacy programs to modern environments. We are experienced in upgrading Visual Basic programs (from version 2.0 and higher) to the latest version of VB.NET, and in upgrading Windows NT, 2000, and XP applications to Windows Vista, 7, and 8.

  • Voltage Input Device For FieldDAQ

    NI

    The Voltage Input Device for FieldDAQ measures up to eight ±10 V channels with 24-bit resolution and simultaneous sample rates up to 100 kS/s/ch. Some models can power sensors, such as pressure sensors, with up to 24 V per input channel. This device offers 500 V channel-to-channel isolation, protecting instrumentation from high-transient voltages. Additionally, the device is IP65 and IP67 rated to be dust-proof and water-submersible, can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. It has an integrated network switch for simplified daisy chaining and provides tight synchronization over time sensitive networking (TSN) for distributed data acquisition systems.The Voltage Input Device for FieldDAQ includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • One, Two, or Four Dual Redundant Interface MIL-STD-1553A/B Test & Simulation Module for PXI Express

    PXIe-1553 - Avionics Interface Technologies

    1, 2, or 4 dual redundant MIL-STD-1553 bus interfaces Concurrent BC, multiple RT (31), and BM operations Full error injection and detection • Data capture filtering, 100% bus recording, and physical bus replay Multi-level Trigger for Capture/Filtering IRIG-B Time Encoder/Decoder Real-Time Recording and Physical Bus Replay Application interfaces supporting C, C++, C#, and .NET development Device Driver Support for: Windows, Linux, and LabVIEW Real Time (others provided on request) 10 high voltage (up to 30V) programmable DIO lines Flight Simulyzer GUI Analyzer software

  • Analog Output Device

    NI

    The Analog Output Device helps you create applications such as stimulus-response, power supply control, deterministic control, and sensor/signal simulation. The Analog Output Device supports various output resolutions, channel counts, and other onboard features, so you can replace several kinds of instruments in your system, including stand-alone proportional integral derivative (PID) controllers, low-speed arbitrary waveform generators, and function generators.The Analog Output Device includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

Get Help