DCA-M Sampling Oscilloscopes
Built on Keysight's digital communication analyzer (DCA) technology, the DCA-M family is recognized as the industry standard for verifying optical transmitter compliance to communications standards. With single to quad optical AND electrical channels in a compact form factor, the DCA-M is ideal for both manufacturing and RND applications. Analyze both multi-mode and single-mode signals with the low-noise, high-sensitivity calibrated reference receivers. The variety of models along with the supporting software and compliance applications ensure you can measure with high precision, whether you analyze electrical or optical devices.
-
Product
28/45 GHz Quad Optical Channel DCA-M
N1092D
Oscilloscope
High accuracy, low cost solution for optical waveform analysis including solutions for 8.4 through 64 GBaud, very low noise and jitter, and fast sampling rates for high throughput.
-
Unlisted Product
28/45 GHz Single Optical Channel DCA-M with Option CDR
N1092A
-
High accuracy, low cost solution for optical waveform analysis including solutions for 8.4 through 64 GBaud, very low noise and jitter, fast sampling rates for high throughput, and integrated clock recovery available.
-
Product
DCA-M High-Accuracy, Low-Cost Solution for Optical Waveform Analysis
N1090A
Oscilloscope
The N1090A DCA-M builds on that legacy by using the high-performance elements of 86100 and 86105C. It can be configured to perform thorough optical transmitter compliance tests at a variety of standard data rates from 1.244 to 11.3 Gb/s and come with 20 GHz electrical channel in option.
-
Product
30/50 GHz Quad Electrical Channel DCA-M
N1094B
Oscilloscope
The N1094 DCA-M builds on that legacy by using the high-performance elements of 86100 and electrical channel hardware of N104X plug-in modules. Electrical channels are available with 30 GHz and 50 GHz bandwidths.
-
Product
30/50 GHz Dual Electrical Channel DCA-M
N1094A
Oscilloscope
The N1094 DCA-M builds on that legacy by using the high-performance elements of 86100 and electrical channel hardware of N104X plug-in modules. Electrical channels are available with 30 GHz and 50 GHz bandwidths.
-
Product
28/45 GHz Dual Optical Channel and 50 GHz Dual Electrical Channel DCA-M
N1092E
Oscilloscope
High accuracy, low cost solution for optical and electrical waveform analysis including solutions for 8.4 through 64 GBaud, very low noise and jitter, and fast sampling rates for high throughput.
-
Product
28/45 GHz Single Optical Channel and 50 GHz Dual Electrical Channel DCA-M
N1092C
Oscilloscope
High accuracy, low cost solution for optical and electrical waveform analysis including solutions for 8.4 through 64 GBaud, very low noise and jitter, and fast sampling rates for high throughput.
-
Product
28/45 GHz Dual Optical Channel DCA-M with Option CDR
N1092B
Oscilloscope
High accuracy, low cost solution for optical waveform analysis including solutions for 8.4 through 64 GBaud, very low noise and jitter, fast sampling rates for high throughput, and integrated clock recovery available.
-
Product
20 GHz Dual Channel Electrical Module
86112A
-
Get high-fidelity measurement and display of waveforms on two electrical channels with 3.5 mm (m) connectors See better representations of your signals with characteristic RMS noise of 0.25 mV (12.4 GHz bandwidth setting), 0.5 mV (20 or 30 GHz bandwidth setting)Test a maximum input signal of ± 2 VDC
-
Product
28/45 GHz Single Optical Channel DCA-M with Option CDR
N1092A
Oscilloscope
High accuracy, low cost solution for optical waveform analysis including solutions for 8.4 through 64 GBaud, very low noise and jitter, fast sampling rates for high throughput, and integrated clock recovery available.
-
Product
60 GHz 2/4 Port Electrical Remote Sampling Head
N1045A
-
60 GHz bandwidth (65 GHz typical)2 or 4 channels per module (user-selectable option; upgradeable)User-selectable bandwidth settings of 60/45/35/20 GHz Electrical Inputs: 1.85mm male or female (user-selectable option)
-
Product
Differential & Single-ended TDR/TDT Module
54754A
-
Achieve superior testing with characteristic RMS noise: 0.25 mV (12.4 GHz bandwidth), 0.5 mV (18 GHz bandwidth), and a maximum input signal of ± 2 VDC Get increased usability with two built-in step generators configurable for 1-port, 2-port common mode, or 2-port differential TDR or TDT measurements Experience easier testing with built-in TDR/TDT calibration, user-selectable edge speed, S-Parameters (requires mainframe FW rev. A.06.01 or later. S-Parameters requires Option 202)
-
Product
Infiniium DCA-X Wide-Bandwidth Oscilloscope Mainframe
86100D
Mainframe
Bandwidth >100 GHz Customize the mainframe for optical, electrical, and TDR/S-parameter analysis Perform fast, accurate, and compliant jitter measurements with ultra-low jitter of 100 fs RMS and noise as low as 250 V Get more than 50 built-in standards-based masks with automated mask margin analysis Easily measure multiple signals in parallel; analyze and acquire up to 16 signals simultaneously Protect your investment with this upgradable and backwards compatible mainframe