Neulog
NeuLog logger sensors are the fruit of innovative thinking in technological training systems for hands-on education in the sciences, high-tech and industry for grade schools, high schools, universities, vocational schools, and after-school activities programs.
- info@neulog.com
- 850 St Paul Street
Rochester, NY 14605
United States of America
-
Product
Multi-Sensor
Panda
-
The NeuLog Panda multi-sensor can be used for any science experiment which utilizes Room Temperature, Light, Barometric pressure, Altitude, Sound, Relative Humidity, Dew-Point, Magnetic Field and G-Acceleration readings.Panda is used for environmental data collection and other experiments in Natural Science, Biology, Physics and Chemistry. It is specially designed for primary school level.The multi-sensor comes pre-calibrated so you can start experimentation right out of the box
-
Product
Barometer Logger Sensor
NUL-221
-
This logger sensor measures atmospheric barometric pressure and can display data in four common units. kPa kilopascal atm atmospheres in Hg inches of mercury mm Hg millimeters of mercuryThe sensor also offers an option to display the measured pressure values in terms of altitude (in meters).
-
Product
Heart Rate and Pulse Logger Sensor
NUL-208
-
This sensor can be used to monitor and compare pulse rates under various exercise and rest conditions. Additionally, it can show changes of blood volume/flow in the finger or ear lobe with time.The sensor has two modes of operation: measuring the BPM (Beats per Minute) of the heart rate or displaying the analog arbitrary value of the measured signal.
-
Product
Temperature Logger Sensor
NUL-203
-
This is one of our most versatile sensors. It can be used in biology to monitor ecological systems, microbiological cultures and to study the effect of temperature on photosynthesis and enzymatic reactions. In chemistry, to study exothermic or endothermic reactions and how the rate of reaction is affected by temperature; in physics it can be used to study heat/energy transfer.
-
Product
RF Communication Module
RF-200
-
The RF Communication module allows remote operation of asingle sensor or a chain of sensors. The remote single sensoror chain is connected to an RF Communication module and to aBattery Module which powers them all.
-
Product
WiFi Communication Module
WiFi-201
-
The WiFi module is without doubts one of the most advanced and innovating elements of NeuLog. Measurements with NeuLog sensors can be performed through any device which uses the Wi-Fi technology, such as iPads and Tablets with Android, PC computers with Windows / Linux or Macintosh with OS. These can all communicate with the Wi-Fi adaptor to begin a unique experience of data acquisition.
-
Product
Dew Point Logger Sensor
NUL-245
-
This sensor measures temperature and humidity in a volume and gives the temperature below which the water vapor in that volume of air (at a constant barometric pressure) condenses into liquid water (the dew point).
-
Product
Photo Gate Logger Sensor
NUL-209
-
This sensor can be used to study various kinds of motion. With six modes of operation, time, velocity or acceleration can be measured with one or two photo gates and associated timing cards, as well as showing pictorially the status (digital 1 or 0) of the voltage output of the photo gate as timing cards pass through it.
-
Product
Flow Logger Sensor
NUL-224
-
This sensor allows for a stream of water to flow through its inlet and outlet pipes, thus revolving a rotation wheel within it. The wheel is not connected mechanically to anything else, but rather floats on a bearing for minimum friction and the enhancement of its minute accuracy. The measuring is done by monitoring changes in the sensor's surrounding magnetic field.
-
Product
Soil Moisture Loger Sensor
NUL-229
-
This logger sensor is based on measuring the partial vacuum pressure in a tensiometer. A tensiometer is a closed tube with a special ceramic part in its end. The tensiometer is filled with water and put in the soil. If the soil is dry, water goes out by diffusion through the ceramic holes and partial vacuum pressure is created in the tensiometer. When we wet the soil, the partial vacuum in the tensiometer pulls water into the tensiometer and the vacuum decreases. This is why soil moisture is measured in pressure level.
-
Product
Light Logger Sesor
NUL-204
-
This sensor is very versatile with applications in many areas of the natural sciences. It can be used to study photosynthesis in biology, light-emitting chemical reactions in chemistry, the effect of changing voltage on a light-bulb's output in physics and more.
-
Product
Colorimeter Logger Sensor
NUL-219
-
The colorimeter measures transmittance and absorbance of red, orange, green and blue light components projected on a solution. The colorimeter logger sensor has an opening for a special square solution cuvette. It turns on four different lights in known values and measures the received light that passes through the solution.
-
Product
Oxygen Logger Sensor
NUL-205
-
This sensor can be used to make measurements of the level of free oxygen in air or dissolved oxygen in water. The free oxygen in air mode is used to measure changes in oxygen levels during combustion or in reactions that produce oxygen (hydrogen peroxide decomposition). The dissolved and free oxygen modes are very useful in the study of photosynthesis.
-
Product
Chloride Logger Sensor
NUL-239
-
The NeuLog chloride sensor can be used to measure the concentration of chloride ions (Cl-) in aqueous samples. This measurement can be an indication of the salinity of water samples.The sensor can be used to study samples of drinking water with different degrees of chlorination.
-
Product
Spirmeter Logger Sensor
NUL-216
-
The logger sensor enables measuring the volume of our lungs. The sensor includes a tube and it measures the air flow that passes through it. The volume (in liters) is calculated by the software area calculation function.