Physitemp Instruments
Physitemp Instruments Inc is an electrical/electronic manufacturing company.
- 800.452.8510
973.779.5577 - (973) 779-5954
- 189 Sargeant Avenue
Clifton, NJ 07013
United States of America
-
Product
Flexible Implantable Microprobe
IT-1E
-
IT-1E Flexible Implantable Microprobe - For ultra fast measurements and for use on micro-size specimens. Similar to our most popular IT-18 microprobe but the sensor bead is exposed, resulting in the same ultra-fast response time of the IT-23 but with the Teflon™ sheath strength of the IT-18. Time constant 0.005 seconds. Tissue Implantable with a 18 gauge needle (supplied). Rather fragile at tip. Coated in Teflon™. Maximum Temperature 150°C. Isolated. Probe tip diameter .011", sheath diameter .025'' . 3 foot lead.
-
Product
Needle Microprobe
MT-26/4HT
-
Fast-response 26 gauge needle probe, (needle length is 4 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
Product
Gauge Type T Thermocouple Wire
W-TW-44
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Rectal Probe For Mice (Isolated)
RET-3 ISO
-
• An isolated sensor (can be used with monitoring equipment where electrical interference from other electrodes may be present).• Reinforced strain relief for applications where probe is in more frequent use.• Smooth ball tip. Stainless steel shaft - 3/4'' long, .028'' diameter. Tip diameter .065'', 5 foot lead length. Time constant 0.5 seconds.
-
Product
Needle Microprobe
MT-23/8HT
-
Fast-response 23 gauge needle probe, (needle length is 8 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
Product
Gauge Type T Thermocouple Wire
W-TW-24
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Gauge Type T Thermocouple Wire
W-TW-36
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Gauge Type T Thermocouple Wire
W-TW-40P2
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Gauge Type T Thermocouple Wire
W-TW-44P2
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Gauge Type T Thermocouple Wire
W-TW-44P
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Thermalert Clinical Montoring Thermometer With Analog Output
TH-5/AOP
-
The TH-5?AOP is one of our most economical precision thermometers in the Physitemp product line. The TH-5/AOP offers the same high accuracy (0.1°C ±1 digit) and resolution as all our other thermometers, but with a narrow temperature range. The TH-5 is ideally suited for either a laboratory or hospital setting where continuous temperature readings within the physiological range are sufficient.
-
Product
Rectal Probe For Rats
RET-2
-
• Smooth ball tip. Stainless steel shaft - 1'' long, .059'' diameter. Tip diameter .125'', 5 foot lead length. Time constant 0.8 seconds. Not Isolated
-
Product
Immersion Probe For Liquids
DPT-24
-
DPT-24 Immersion Probe for Liquids - 24'' #304 stainless steel welded shaft. Wooden Handle. Diameter is .3/16'' diameter. Immersible. Maximum temperature 350°C, Time constant 2 Seconds. 5 foot lead. Not isolated.
-
Product
Thermal Microscope Stage
TS-4MP
-
With our TS-4MP Thermal Stage, a specimen on a microscope slide or culture dish can be maintained at any temperature between -20°C and +60°C. Setup is easy, takes little time, and the controller will regulate the stage temperature to within +/-0.1°C















