General Purpose Probes
PIT-12
-
PIT-12 General Purpose Probe for Pressurized Systems - 12'' #304 stainless steel shaft. Diameter is 1/16''. Immersible. Maximum temperature 350°C, Time constant 0.5 Seconds. Shaft Terminated in a sub-miniature Type T Thermocouple plug. 10 foot Sub Miniature Type T extension lead supplied. Not isolated.
-
Product
Animal Temperature Controller- Dual Feature
TCAT-2DF
-
This is a combination version which includes both and AC outlet for controlling primarily resistance loads such as heat lamps, AC powered warming blankets and a low-voltage, low noise DC output for heating pads. This version allows you to controls a variety of different loads.
-
Product
Gauge Type T Thermocouple Wire
W-TW-44
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Thermometer REPLACED BY PTM-1
BA T-7001H
-
In applications where clinical accuracy is not mandatory and cost is a consideration , the BAT-7001H is Physitemp‘s most compact, low cost thermocouple thermometer. The Model BAT-7001H is a high performance, precision hand-held instrument for the measurement of temperature using Type T (copper-constantan) thermocouples. This versatile instrument measures temperature in both °C and °F. The internal memory of the micro-computer stores the minimum and maximum measured temperature for instant recall via the LCD display. BAT-7001H operates on a 9V battery.
-
Product
Ultra Fast Flexible Implantable Microprobe
IT-23
-
IT-23 Flexible Implantable Microprobe - For ultra fast measurements and for use on micro-size specimens. Time constant 0.005 seconds. Tissue Implantable with a 23 gauge needle (supplied). Fairly fragile. Sensor wires are twisted TFE Teflon™ insulated. Maximum Temperature 150°C. Isolated. Probe diameter .011", 3 foot lead.
-
Product
Foot Rest
VFR-1
-
The optional footrest is designed to be used with the Vibratron-II. The foot rest is 12'' long x 8'' wide x 4.25'' high with adjustable non-slip leveling feet ( feet are adjustable to add up to 1/2'' of additional height if needed). Surface of the footrest is a white hygienic non-skid vinyl covering and can be easily cleaned between uses. The unit is large enough to accommodate both feet and may also be used as an armrest when testing upper extremities. The weight of the unit is approximately 4.5 pounds. The footrest can also be purchased as an option to the NTE-2A .
-
Product
Temperature Data Acquistion
THERMES-USB RF
-
Physitemp’s original Thermes high accuracy ISA based data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. For information on our wide selection of Type T Thermocouple temperature probes.
-
Product
Needle Microprobe
MT-4
-
Fast-response 29 gauge needle probe with blunt tip, (needle length is 1cm) for instant readings. Good for instant skin temperature and surface temperatures, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
Product
Gauge Type T Thermocouple Wire
W-TW-36
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Vibration Sensitivity Tester
Vibratron II
-
The Vibratron II provides a non-invasive means of measuring the sensitivity to vibration of large nerve fibers of a patient's fingers and toes. Reliable quantitative measurements are achieved with a test that takes only minutes to administer. A two-alternative forced choice procedure is used to determine the degree of sensitivity for comparison to normals.
-
Product
Flexible Implantable Microprobe
IT-18(10 FOOT)
-
IT-18(10 FOOT) Flexible Implantable Microprobe with 5 foot lead - Implantable in semi-solids and tissue with 18 gauge needle (supplied). Also for immersion in various solutions and rectal temperatures of small animals. Totally sheathed in chemical resistant Teflon™. Quited rugged. Maximum Temperature 150°C . Isolated. Probe diameter .050" (14 gauge represents the needle gauge that the probe can be inserted through). Time constant 0.3 seconds.
-
Product
Gauge Type T Thermocouple Wire
W-TW-30
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Lite Software
DASYLAB
-
Dasylab lite software provides all the necessary functions to display and store temeprature data in digital and graphical formats in real time. Users may customize the display to suit their particular application. The Dasylab Basic version provides additional features for data manipuation and statistical analysis. Dasylab basic is also required if using multiple THERMES systems.
-
Product
Gauge Type T Thermocouple Wire
W-TW-20
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.