Showing results: 16 - 30 of 88 items found.
-
W-TW-44TEF -
Physitemp Instruments
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
W-TW-40P2 -
Physitemp Instruments
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
W-TW-36P2 -
Physitemp Instruments
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
W-TW-30 -
Physitemp Instruments
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
W-TW-40P -
Physitemp Instruments
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
W-TW-26 -
Physitemp Instruments
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
HT-2 -
Physitemp Instruments
HT-2 ''Workhorse'' General Purpose Probe - designed for temperature measurement of liquids, gases and semi-solids. Plastic handle with straight 9'' stainless shaft. Not good for surface temperatures. Maximum temperature 400°C, Time constant 0.5 Seconds. 5 foot lead. Not isolated.
-
BT-1 -
Physitemp Instruments
BT-1 General Purpose Probe - Probably our best general purpose probe designed for temperature measurement of solids, liquids, gases and semi-solids. Welded stainless-stell shaft, plastic handle. Tip is .028'' diameter bent at right angle to probe to facilitate accurate surface measurements. Immersible. Maximum temperature 240°C, Time constant 0.15 Seconds. 5 foot lead. Not isolated.
-
HT-1 -
Physitemp Instruments
HT-1 ''Workhorse'' General Purpose Probe - designed for temperature measurement of liquids, gases and semi-solids. Plastic handle with straight 3'' stainless shaft. Not good for surface temperatures. Maximum temperature 400°C, Time constant 0.5 Seconds. 5 foot lead. Not isolated.
-
DPT-12 -
Physitemp Instruments
DPT-12 Immersion Probe for Liquids - 12'' #304 stainless steel welded shaft. Wooden Handle. Diameter is .3/16'' diameter. Immersible. Maximum temperature 350°C, Time constant 2 Seconds. 5 foot lead. Not isolated.
-
DPT-24 -
Physitemp Instruments
DPT-24 Immersion Probe for Liquids - 24'' #304 stainless steel welded shaft. Wooden Handle. Diameter is .3/16'' diameter. Immersible. Maximum temperature 350°C, Time constant 2 Seconds. 5 foot lead. Not isolated.
-
BAT-12 -
Physitemp Instruments
The BAT-12 laboratory digital thermometer is Physitemp's most popular and best selling instrument due to its versatility, quality construction and low cost.The BAT-12 has 0.1°C resolution and super accuracy of 0.1°C ±1 digit between 0-50°C, 0.1°C ± 1 digit over full range.The temperature range is -100 to 200°C. The BAT-12 provides fast readings, usually within 2-5 seconds depending on the temperature probe in use.
-
BAT-12R -
Physitemp Instruments
The BAT-12R rechargeable laboratory digital thermometer is Physitemp's most popular and best selling instrument due to its versatility, quality construction and low cost. The BAT-12R has 0.1°C resolution and super accuracy of 0.1°C ±1 digit between 0-50°C, 0.1°C ± 1 digit over full range.The temperature range is -100 to 200°C. The BAT-12 provides fast readings, usually within 2-5 seconds depending on the temperature probe in use.
-
ICT-4 -
Physitemp Instruments
ICT-4 Micro-Surface Microprobe - For use on integrated circuits and other micro specimens. 0.013'' diameter .5'' straight stainless steel shaft; slightly protruding sensor bead to facilitate temperature probing. 5'' tubular handle fits micro-manipulators. Maximum intermittent temperature 200°C, continuouse use 100°C, Time constant 0.025 Seconds. 5 foot lead. Not isolated.
-
BAT-10 -
Physitemp Instruments
This versatile thermometer has a wide temperature range and can be used in applications as diverse as cryogenic measurements for blood banking and cryosurgery, skin temperature measurements in exercise experiments, liquid measurements in spectrophotometer cuvettes, melting points of plastics and all types of animal and insect temperature measurements.