BAUR
The BAUR testing and measurement technology prevents damage to networks and systems, allows for accurate planning of investments for maintenance and locates faults as precisely and quickly as possible. For the reliability of your networks and systems.
- +43 5522 49410
- +43 5522 49413
- headoffice@baur.eu
- Raiffeisenstraße 8
Sulz, 6832
Austria
-
Product
Cable Sheath Testing and Fault Location System
Shirla
-
Cable fault location with the BAUR shirla. Shirla the fault location system is used for cable and cable sheath testing as well as for pre-location and pinpointing of cable faults. The pre-location based on the measuring bridge principle according to Murray and Glaser that is designed especially for power cables, also enables pre-location for control and lighting cables. Null balance and evaluation take place automatically.* Cable and cable sheath testing up to 10 kVC* Resistance measurement* Cable and cable sheath fault pre-location with precision measuring bridge* Adjustable cable sections that can be defined with length, conductor cross-section and material respectively and can be considered in the distance calculation
-
Product
Surge and Test Generator
STG 600
-
Cable fault location with the BAUR STG 600. The STG 600 surge and test generator is a multifunctional cable fault locator for low voltage networks. The surge and test generator is used for cable testing as well as for precise location of high-resistive and intermittent faults in low voltage cables.* Specifically for use in low-voltage networks* High surge energy: 600 or 1000 J** Light, compact and transportable* Single systems for cable testing and faults location
-
Product
Portable PD Diagnostics System
PD-TaD 60
-
The PD TaD 60 portable PD Diagnostics system is used in combination with a BAUR VLF generator frida for carrying out partial discharge measurement and location.* Comprehensive 360° cable analysis – with parallel partial discharge and dissipation factor measurement* Time-optimised and safe cable condition evaluation* The lightest and most compact PD measuring device up to 60 kVpeak* Developed for portable use on site
-
Product
Partial Discharge Inductor
Tracy
-
Cable testing and diagnostics with the BAUR tracy. The BAUR tracy partial discharge inductor induces a signal at the apparent fault location in the cable from outside. In combination with any PD measurement system, e.g., PHG TD/PD, the induced signal can be located and compared with the result of the partial discharge pre-location. The partial discharge location can thus be determined precisely.* Portable, battery-operated signal coupling device* Suitable for cables and cable accessories* Inductive signal coupling* Aviods costly, unnecessary replacements of PD-free cable accessories
-
Product
Surge Voltage Generator
SSG 2100
-
Cable fault location with the BAUR SSG 2100. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit
-
Product
Cable Fault Location System
BAUR Syscompact 2000 Portable
-
Cable fault location system Syscompact 2000 portable. The cable fault location system Syscompact 2000 portable is used for precise location of high-resistance and intermittent faults in low and medium voltage cables.* Fast and reliable* Precise, dependable cable fault location* High performance high voltage unit* Integrated proven cable fault pre-location methods
-
Product
Surge Voltage Generator
SSG 1500
-
Cable fault location with the BAUR SSG 1500. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit