BAUR
The BAUR testing and measurement technology prevents damage to networks and systems, allows for accurate planning of investments for maintenance and locates faults as precisely and quickly as possible. For the reliability of your networks and systems.
- +43 5522 49410
- +43 5522 49413
- headoffice@baur.eu
- Raiffeisenstraße 8
Sulz, 6832
Austria
Categories
-
product
Time Domain Reflectometer
TDR 500
Handheld Time Domain Reflectometer. The handheld time domain reflectometer TDR 500 and TDR 510 are used for fault location in all metal cables such as power cables, coaxial cables, data cables and communication cables.* Configurable for various measurement ranges and cable types* Standard-compliant, safe measurements on life cables through the measurement category CAT IV / 600 V (with separation filter)* Ideal for fault location in the area of telecommunication, video technology, data and security technology
-
product
Audio Frequency Transmitter
TG 600
Cable fault location with the BAUR TG 600. The TG 600 audio frequency transmitter was designed specifically for the precise location of cable faults and joints using the twist method. The display of the input and output current makes selection of the correct adjustment easier.* High-performance audio frequency transmitter up to 600 VA* Frequency of 2 or 10 kHz, quartz-stabilised (other frequencies on request)* Potential-free output* Impedance adjustment in 8 steps from 0.3 to 300 Ω
-
product
Software
ITS Lite
The BAUR software ITS Lite is used to read, design and archive measurement logs of the DPA 75 C, DTA 100 C, DTA 100 C, DTL C BAUR oil testers. Automatic archiving of measurement logs in PDF format and as text file (*.txt) Structured storage and allocation of measurement logs Customised layout of measurement logs Fast and uncomplicated access to measurement data
-
product
High-Voltage Test Device
PGK 70/2.5 HB
Cable testing and diagnostics with the BAUR PGK HB. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.* Operation as DC or Ac testing device* Polarity of the DC voltage can be easily be reserved* Robust and durable
-
product
VLF Testing and Diagnostics Unit
Viola TD
Cable testing and diagnostics with the BAUR viola TD. The portable and high performance high-voltage testing and diagnostics device is available in two different configurations:viola: Used for cable and cable sheath testing of electrical equipment and medium-voltage cables up to 35 kV. Another function is insulation testing on electrical equipment. viola TD: Expands the functional scope of viola with the tan delta diagnostics and Monitored Withstand Test (MWT) that combines the cable testing and dissipation factor measurement. This allows for an accurate and comprehensive assessment of the cable condition.* Cable testing and dissiation factor diagnostics in one device* High performance and compact* Easy and quick test setup* Automatic testing and diagnostic sequences
-
product
Phase Detector
Paula
BAUR paula phase detector. The paula phase detector is used for clear phase identification in earthed and shorted medium and high-voltage cables. With the help of the measurement procedure tried and tested over many years, paula delivers precise phase allocation without scope for interpretation and corresponds to the highest safety standards for tasks on and close to electric equipment.* Clear phase determination possible in cable lengths up to 40 km* Highest level of safety when used on earthed and shorted cables in compliance with EN 50110-1 (DIN VDE 0105-100)* Suitable for all switchgear constructions due to compact design of the signal injectors* Ready for operation for up to 2 weeks (standby mode)
-
product
High-Voltage Test Device
PGK 150 / 5 HB
Cable testing and diagnostics with the BAUR PGK H. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.* Testing of medium- and high-voltage cables* DC voltage testing of up to 150 kV output voltage with positive or negative polarity* AC voltage testing - up to 110 kV for switchgear, busbars and insulating elements* Easy-to-maintain 2-piece design
-
product
Handheld Online PD Detector
PD-SGS
Quick identification of PD activities in switchgear and cable accessories. The BAUR PD-SGS handheld online PD detector is used to conduct rapid initial tests for PD activities on live switchgear. Potential weak points are immediately signalled acoustically and numerically.* Initial rapid condition evaluation of switchgear and cable accessories during mains operation* Ideal for quick checks of MV and HV switchgear* Two integrated sensors:TEV sensor records PD on the surfaces of switchgearsAcoustic sensor records PD inside switchgears* Greater safety for test personnel switchgear tested for safety risks before starting work
-
product
High-Voltage Test Device
PGK 110 HB
Cable testing and diagnostics with the BAUR PGK HB. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.* Testing of medium- and high-voltage cables* DC voltage testing of up to 110 kV output voltage with positive or negative polarity* AC voltage testing - up to 80 kV for switchgear, busbars and insulating elements* Easy-to-maintain 2-piece design
-
product
Audio Frequency Transmitter
TG 20/50
Cable fault location with the BAUR TG 20/50. The TG 20/50 is a portable, battery-operated audio generator with a built-in charging unit. Together with the UL audio frequency receiver and the SP detecting rod, the TG 20/50 is used for cable tracing, twist method and for determining the depth of cables and metal pipes.* Automatic or manual impedance adjustment* Charging unit and rechargeable battery integrated; battery or mains operation* Continuous or cyclical output* Two output frequencies selectable
-
product
Report Manager
External USB interface for BAUR oil testers. BAUR Report Manager, the external USB interface for oil testers, is used to automatically export measurement logs from BAUR oil testers to a USB drive. Extensive language support and the integration of customised logos simplify professional reporting.
-
product
Cable Test Vans and Systems
Precise cable fault location, testing of new and diagnostic testing of existing cable routes – the BAUR cable test vans are suitable for any operation. Fast and reliable. Exactly adapted to individual requirements and predefined vehicle systems.
-
product
VLF Test System
BAUR PHG 70 portable
Portable, high performance test generator with VLF truesinus technology. The BAUR PHG 70/80 portable VLF test systems are used for cable and cable sheath testing of medium-voltage cables of up to 50 kV and electrical equipment.* 3 voltage shapes in one device: VLF truesinus, VLF square wave and DC voltage* For medium-voltage cables of up to 50 kV operating voltage* Cable testing, fault conditioning, cable sheath testing
-
product
Surge Voltage Generator
SSG 3000
Cable fault location with the BAUR SSG 3000. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* high surge energy in each voltage range
-
product
Oil Breakdown Voltage Tester
DTL C
Insulating oil testing with the BAUR DTL C. The established analysis and diagnostic testing of insulating oils with the BAUR DTL C deliver valuable findings in scientific work, research and development. Extensive knowledge on the current state of insulating materials is gaining importance even for the mains network operator. The BAUR DTL C offers the latest and most precise information for efficient oil management in plants in the electricity and other industries.