NI
NI is a technology pioneer and leader in virtual instrumentation - a revolutionary concept that has changed the way engineers and scientists in industry, government, and academia approach measurement and automation.
- +1 877 388 1952
- 11500 N Mopac Expwy
Austin, TX 78759-3504
United States of America
-
Product
PXI-8360, MXI-Express Interface, PXI Remote Control Module
779501-01
Interface
MXI-Express Interface, PXI Remote Control Module—The PXI‑8360 allows you to control PXI and CompactPCI systems from your PC using a fully transparent MXI‑Express link. It is installed in a PXI chassis and uses a PCI Express‑to‑PCI bridge to interface with an installed PCI‑8360 through a copper, x1 MXI‑Express cable.
-
Product
USB-6361, 16 AI (16-Bit, 2 MS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device
781442-01
Multifunction I/O
16 AI (16-Bit, 2 MS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device - The USB-6361 offers analog I/O, digital I/O, and four 32-bit counters/timers for PWM, encoder, frequency, event counting, and more. Onboard NI-STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The USB-6361 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
PXIe-1065, 18-Slot (9 PXI Slots, 3 PXIe Slots), Up to 3 GB/s PXI Chassis
779730-01
Chassis
PXIe, 18-Slot (9 PXI Slots, 3 PXIe Slots), Up to 3 GB/s PXI Chassis—The PXIe‑1065 is designed for a wide range of test and measurement applications and provides a high-bandwidth backplane. The NI PXIe‑1065 has nine PXI peripheral slots, one PXI Express slot with system timing capabilities, three PXI Express slots, and four hybrid slots that accept both PXI and PXI Express peripheral modules.
-
Product
NI-9209, ±10 V, 500 S/s, 16-Channel C Series Voltage Input Module
783729-01
Voltage Input Module
±10 V, 500 S/s, 16-Channel C Series Voltage Input Module - The NI‑9209 performs single-ended or differential analog input. This module provides 60 VDC CAT I isolation and built-in 50/60 Hz filtering, making it a valuable addition to industrial measurement systems.
-
Product
FlexRay Interface Device
FlexRay Interface
FlexRay Interface Devices provide two fully functional FlexRay interfaces, allowing an individual engine control unit (ECU) to be connected to the interface when other cold-start nodes are not available. You also can use the interfaces individually to connect two separate FlexRay networks while maintaining full performance on each interface. FlexRay Interface Devices work well in applications such as hardware-in-the-loop (HIL) simulation, rapid control prototyping, bus monitoring, and automation control.
-
Product
NI Electric Motor Simulation Toolkit
-
PMSM, ACIM, SRM, and power inverter models for high-performance simulationHigh-fidelity simulations with support for user-defined parameter lookup tables or JMAG-RT models. Open software for full flexibility and customizationLabVIEW project templates to build a software-only simulation and hardware-in-the-loop application. Direct integration with NI VeriStand for configuration-based real-time test. Models for desktop simulation, LabVIEW Real-Time simulation, and FPGA-based simulation
-
Product
Standardize Production Test Software For PCBAs And Electronic Devices
test
The vast majority of test project man-hours are spent on software development, so the choices that teams make in software tools and architecture have significant impact on deployment schedules. Standardizing software across a team or organization increases both efficiency and proficiency, lowering the risk of missed deadlines and improving test quality and reliability. Test software must:
-
Product
USB Cable, Type-C to Right Angle Type-C, USB 3.2 Gen 1, 2m
789957-02
USB Type C
USB Cable, Type-C to Right Angle Type-C, USB 3.2 Gen 1, 2m
-
Product
*RS485 Null-Modem Cable, DB-9 Female to DB-9 Female, 1m
183283-01
Serial Cable
RS485 Null-Modem Cable, DB-9 Female to DB-9 Female, 1m
-
Product
PXI-6521, 16-Channel, ±30 VDC, 8 Sink/Source Inputs, 8 Relay Outputs, Isolated PXI Digital I/O Module
779313-01
Digital I/O
16-Channel, ±30 VDC, 8 Sink/Source Inputs, 8 Relay Outputs, Isolated PXI Digital I/O Module—The PXI‑6521 is an industrial digital I/O module with high channel isolation and industry-standard 24 V logic levels. For added safety, the PXI‑6521 requires a keyed connector. If a computer or application fault occurs, the PXI‑6521 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. It also features programmable power-up states, digital filtering, and change detection for optimal control over your application.
-
Product
Cable, 10 Pos Combicon to Pigtail, 1 Meter
190656-01
Multifunction Cable
Cable, 10 Pos Combicon to Pigtail, 1 Meter
-
Product
GPIB Cables
-
GPIB Cable, sometimes referred to as the X13 cable, connects your system to GPIB devices or interfaces for instrument control. This standard shielded cable can connect PXI Controllers to instrument control devices and is offered in different lengths.
-
Product
MXI-Express Cable with Communication Levels up to Gen 3 x8
782317-03
MXI Express
MXI-Express Cable, Gen 2 x8, Copper, 3m
-
Product
NI-9206, ±10 V, 250 kS/s, 16-Bit, 32-Channel, 60 VDC Isolation C Series Voltage Input Module
779526-01
Voltage Input Module
±10 V, 250 kS/s, 16-Bit, 32-Channel, 60 VDC Isolation C Series Voltage Input Module - The NI‑9206 performs differential analog input with four programmable input ranges. The module provides up to 600 VDC (400 VDC in Europe) channel‑to‑earth ground isolation, making the module ideal for accurately monitoring large fuel cell and battery stacks. By referencing the module common (COM) to the middle of the NI‑9206 bank, you can measure 16 consecutive cells and remain within 10 V of the module COM.