Amperis sl
Amperis is a company specialising in state-of-the-art instrumentation for the diagnosis and testing of electrical substations. The company is located in the northwest of Spain, in the Polígono Industrial das Gándaras in the city of Lugo. After completing the construction and since November 2017 the company is located in the new headquarters, located at 14 Barbeito María Street. The new Amperis headquarters has offices and a new, more modern warehouse, with more internal conveniences and more facilities for the exit and entry of goods, with the aim of always providing a better service to the customer.
- (+34) 982 20 99 20
- info@amperis.com
- Barbeito María 14
Lugo, 27003
Spain
-
Product
The Lightest Micro-ohmmeter In The Industry
RMO-H
-
The RMO-H is a portable, battery-operated micro-ohmmeter based on state-of-the-art technology, using the most advanced battery mode and switching technique available today. The high-capacity Li-Po battery allows the generation of a ripple-free DC current of up to 300 A. The test current is user-selectable and generated in an automatically regulated test ramp. During the test, the RMO-H increases the current before the measurement and decreases it afterwards. This significantly reduces magnetic transients.
-
Product
Transformer Winding Resistance Meters
RMO TT Series
-
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.
-
Product
Insulation Resistance Meter
AMIC-2505
-
Measurement of insulation resistance: 500,1000 and 2500V (2TΩ) ; 2 and 3 wire method ; Measurement of DC and AC voltages at 0...600V ; Measurement of leakage currents
-
Product
Short Circuit Loop Impedance Meter
AMZC-304
-
Short circuit loop impedance measurement in networks with nominal voltage: 220/380V, 230/400V, 240/415V, with frequency 45…65Hz ; Short circuit loop impedance measurement with 15mA current, without triggering RCD. ; Detection of the replacement L and N in the socket and automatic swap in the meter
-
Product
Multigas Analyser
Rapidox 5100
-
The Rapidox 5100 Multigas Analyser is a high specification portable instrument designed for the analysis, control and monitoring of gas in a wide range of applications including; biogas, syngas, anaerobic digestion and fermentation processes.
-
Product
Rapidox 6100 Pump Back Gas Analyser
-
The Rapidox SF6 6100 Pump Back is a fully-automatic zero-emissions SF6 gas analyser, designed for controlling and monitoring the quality and purity of gas used in high voltage switchgear, circuit breakers and transformers.
-
Product
Portable Gas Analyser
Rapidox 6100
-
The Rapidox SF6 6100 Portable is designed for controlling and monitoring the quality of SF6 in medium and high voltage gas insulated electrical equipment.
-
Product
Short Circuit Loop Impedance Meter
AMZC-305
-
Loop impedance measurement with resolution 0,01Ω ; Loop impedance measurement without tripping the circuit breaker > 30mA with resolution 0,01Ω (100...440V) ; Measurements possible in installations 110/190V, 115/200V, 127/220V, 220/380V, 230/400V, 240/415V, 290/500V and 400/690V (range 100...750V)
-
Product
Telurometer
AMRU-200 GPS
-
*The only meter on the market that implements all measurement methods:*Technical method of 2, 3 or 4 poles*Drive method (4/10μs, 8/20μs, 10/350μs).*Double-clamp method without the need for auxiliary electrodes.*Soil resistivity.
-
Product
Circuit Breaker Analyzer
CAT Standard Series
-
The CAT Standard series circuit breaker analyzers & timers are stand-alone or a PC-controlled digital instruments for circuit breakers condition assessments. The timing channels record closing and opening of the arcing, resistor, and auxiliary contacts. CAT Standard series records graphs of both, trip and close coil currents and displacements of the HV and MV circuit breaker moving parts. The main contact channels can also measure the resistance value of the pre-insertion resistors (if present in the circuit breaker). Test results can be downloaded to a USB memory stick or saved to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Test results can also be printed on the 80 mm (3.15 inch) thermal printer (optional accessory) in tabular and graphical form. CAT Standard series provides an easy selection of different operational modes:
-
Product
Ohmmeter
PDRM-1A
-
The PDRM-1A ohmmeter is very accurate for measuring low resistances. You can measure values from 1µΩ to 200Ω. For this reason, it allows a wide variety of measurements to be made with a single instrument.
-
Product
Wave Quality Analyzer
APQM-711
-
The APQM-711 wave quality analyzer enables measurement, analysis and recording of 50/60 Hz network parameters and wave quality diagnostics according to EN 50160. The APQM-711 is an innovative and unique model, it has Wi-Fi communication with the included tablet. The tablet allows all operations to be carried out remotely and with its 10" touch screen it is very easy to operate. From the tablet you can operate the analyzer intuitively and quickly, we can also perform the preview of live data and reading and analyzing data stored in internal memory.
-
Product
Handheld Circuit Breaker And Timer Analyser
CAT-H Series
-
The operation of the breaker can be initiated in different ways (e.g. from a control room, by a local breaker or externally by a test device) depending on the test conditions. Various time measurement triggers are available to record a measurement under a different test condition:*Coil control channel*Continuous current clamping channel*DC voltage channel
-
Product
Multifunction Meter for Electrical Installations
AMPI-530
-
Measurement of short-circuit loop ; Testing of differential, general and selective protections for differential current ; Measurement of insulation resistance ; Up to 10GΩ ; Voltages: 50 V, 100 V, 250 V, 500 V, 1000 V ; Measurement of earth resistance ; Bi-directional continuity test on PE cables, phase sequence ; Measurement and recording of voltage, frequency, alternating current, cosϕ, power, harmonics and THD
-
Product
Transformer Winding Resistance Meters
TWA Advanced Series
-
The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.















