IBEKO Power AB
Our goal is to always keep providing the world market with the most advanced test solutions for transformers, circuit breakers and batteries
- +1 800 599 8113
+46 70 0925 000 - +46 8 731 77 99
- sales@dv-power.com
- Box 1346
Lidingö, 181 25
Sweden
-
product
Coil Analyzers & Power Supplies
Coil analyzers and power supply units are portable and lightweight devices intended for use in harsh switchyard and industrial environments. The typical application is switchgear and circuit breaker testing when substation battery is not connected or available. An advantage over substation battery is enabled testing in under-voltage and over-voltage conditions. Furthermore, the stable voltage outputs with a very low ripple (<0,5%) enable an analysis of the coil and motor current graphs record...show more -
product
Motor/Generator Test Equipment
Winding ohmmeters RMO-M series measure winding resistance of inductive test objects such as electrical motors and generators. Motor test or generator test of winding resistance is especially important for early-stage failure detection.RMO-M series instruments generate true DC ripple-free current with automatically regulated measurement and discharge process. Even more, test instruments are portable and enclosed in a metal casing.Applications supported by DV Power motor/generator test equipment i...show more -
product
Single-Phase Transformer Winding Resistance Meters
RMO-TT Series
RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO...show more -
product
Electrical Safety Test Equipment
Making a product “safe” requires an understanding of “hazards” that exist in each electrical product. Electrical shock is one of the four fundamental hazards. Because of that, it must be a part of any product electrical safety evaluation. Even though a product requires an electrical power source and uses electrical or electronic components, it should not present an electrical shock hazard to the user.Ground bond or earth continuity testing prevents electrical shock hazards. Similarly to a fault ...show more -
product
Circuit Breaker Analyzers & Timers
CAT Advanced Series
DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels ...show more -
product
Single-Phase Transformer Winding Resistance Meters
RMO-TD Series
Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instrume...show more -
product
Battery Extra Load Units
Performing capacity/discharge test on a high-capacity battery may be challenging since high requirements are set on the discharge system. In cases when discharge test times need to be reduced, high load capacities are required from the discharge system. The battery extra load unit BXL is an additional load unit designed especially for this purpose.It is primarily used with BLU battery testers. However, the unit is a universal add-on device. This means it can be used as an additional load with an...show more -
product
Battery Supervisors
DV Power manufactures ideal tools for maintenance, troubleshooting and performance tests on stationary batteries.Capacity testing is performed in order to detect which cells in the string should be replaced by measuring a cell voltage, temperature, inter-cell connection voltage, and specific gravity.IEEE standards for stationary battery applications also stipulate measuring these key parameters during periodic battery inspections.DV Power provides two types of instruments:BVS series – for automa...show more -
product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables...show more -
product
Micro-Ohmmeters
RMO-A Series
The RMO-A is a portable micro-ohmmeter designed for contact resistance measurements of switchgear during manufacturing, commissioning and maintenance stages. This micro-ohmmeter is widely used by medium and high-voltage circuit breakers manufacturers. Other typical applications are testing of disconnecting switches, high-current bus bar joints, cable splices, and different high-current links. It accurately measures not only in factory environments but also in high-induction fields and substation...show more -
product
Three-Phase Transformer Demagnetizer
DEM60C
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument trans...show more -
product
Micro-Ohmmeters
Contact resistance measurement is one of the most important and common tests during switchgear manufacturing, commissioning and maintenance stages. Besides switchgear testing, the RMO digital micro-ohmmeters are designed for simple, safe and efficient testing of:disconnecting switches,high-current bus bar joints,cable splices,welding joints,and different high-current links in factory and high-induction field environments.All DV Power RMO micro-ohmmeters use Kelvin’s 4-point measurement principle...show more