IBEKO Power AB
Our goal is to always keep providing the world market with the most advanced test solutions for transformers, circuit breakers and batteries
- +1 800 599 8113
+46 70 0925 000 - +46 8 731 77 99
- support@dv-power.com
- sales@dv-power.com
- Box 1346
Lidingö, 181 25
Sweden
-
Product
Handheld Turns Ratio & Winding Resistance Tester
TWR-H Series
-
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.
-
Product
Battery Capacity Tester
BLU-C Series
-
BLU-C is the latest solution from DV Power for conducting a comprehensive battery capacity test. This universal instrument is applicable to any battery string, such as lead-acid, Li-Ion, Ni-Cd, and others, with voltages up to 800 V DC.BLU-C tester simplifies battery testing in multiple ways. The instrument provides monitoring of discharge parameters (graphically and numerically) in real-time on a 7-inch touch screen display. The instrument also enables measurement and monitoring of cell parameters (voltage/intercell voltage/temperature), which makes it a complete stand-alone discharge test system.The capacity tester is compatible with DV-B Win software. Because of that, the user can view detailed numerical and graphical presentations of key parameters, and create reports in various formats.The capacity test is performed in a user-friendly way according to battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22 and other.The battery tester enables setting the discharge current up to 300 A, with 0,1 A resolution. If higher currents are required, BLU-C units can be connected in parallel, or BXL additional load units can be used.The user can select one of three discharge modes: Constant current, Constant power, Constant resistance. Additionally, different battery duty cycles can be simulated using user-selectable discharge profiles.Testing can be carried out without disconnecting the battery from the equipment it supplies.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
-
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
Product
Battery Voltage Recorder
BVR Series
-
Battery voltage recorders from BVR series are designed to serve as a support tool for cell voltage measurement during battery capacity testing.During capacity testing, cell voltage, temperature, inter-cell connection voltage, and specific gravity should be measured in order to determine failling cells in the string that should be replaced.Furthermore, IEEE standards for stationary batteries applications stipulate periodical measurement of overall string voltage, as well as cell voltage and temperature.The BVR Series is the perfect tool for that purpose. All measurements are automatically saved in device’s internal memory. Additionally, DV-B Win software helps the user to download all measured results. Furthermore, the user can create test reports and export them to various formats.BVR series includes two models: BVR11 and BVR22. These are rechargeable handheld devices intended for performing monthly battery inspections and support tools during capacity testing. The list of the applications of these instruments includes:Efficient supplement to BLU series of battery load units during battery discharge testingMonthly inspections of large battery banksAmbient temperature measurementCurrent measurement using current clampsUSB and Bluetooth communication with PCSimultaneous string voltage and current measurement to analyze a discharge test processThe BVR22 model provides Bluetooth communication with an external density meter, for transferring electrolyte specific gravity and temperature readings.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Advanced Series
-
TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.
-
Product
Battery Capacity Tester
BLU-T Series
-
Battery load bank BLU-T is a powerful and lightweight solution designed for condition assessment of telecommunication and radio equipment backup supply. This instrument can perform the battery capacity test on battery strings such as Pb, Li-ion, Ni-Cd, and others. It tests battery strings with voltages in the range of 0,9 – 70,5 V DC. As a special feature, the BLU110T model enables capacity testing of single PB, Ni-based as well as Li cells (with current up to 100 A).The capacity test is conducted in an accurate, user-friendly way. Also, it is in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.BLU-T battery load bank enables setting the discharge current up to 350 A, with 0,1 A resolution. If higher currents are required, the BLU-T units can be connected in parallel, or BXL-T additional load units can be linked.The instrument offers a high power-to-weight ratio. BLU-T series has models starting from 12,8 kg / 28.2 lbs and up to 19,2 kW of power.A user can select one of three discharge modes: Constant current, Constant power, Constant resistance. Additionally, different battery duty cycles can be simulated using user-selectable discharge profiles.Discharge parameters can be monitored in real-time during the capacity test. A 4,3-inch touch screen shows overall battery voltage, discharge current, discharge test time and capacity during the entire test. Also, the capacity tester is compatible with DV-B Win software. A user can view a detailed numerical and graphical presentation of key parameters, and create reports in various formats.Testing can be carried out without disconnecting the battery from the service.
-
Product
Transformer Test Equipment
-
DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.
-
Product
Coil Analyzers & Power Supplies
-
Coil analyzers and power supply units are portable and lightweight devices intended for use in harsh switchyard and industrial environments. The typical application is switchgear and circuit breaker testing when substation battery is not connected or available. An advantage over substation battery is enabled testing in under-voltage and over-voltage conditions. Furthermore, the stable voltage outputs with a very low ripple (<0,5%) enable an analysis of the coil and motor current graphs recorded with circuit breaker analyzers from different vendors.SAT40AD, POB30AD, and POB40AD are unique devices in the market due to their dual purpose:Power supply for coils and spring-charging motorsTesting circuit breaker’s coils, motor, and auxiliary circuitAll DV Power coil analyzers and power supply units have four separate outputs for opening and closing coils.SAT40AD has two powerful motor outputs (AC and DC) which can withstand up to 40 A inrush current.POB30AD and POB40AD have DC motor output rated up to 30 A and 40 A respectively. With the use of motor outputs, POB and SAT can also be used as a power source or a temporary battery charger.SAT40A II series instruments can be controlled via PC. The DV-Win application software is used to control both SAT and CAT (Circuit Breaker Analyzers & Timers) devices at the same time, making a unique test system for switchgear and circuit breaker testing.
-
Product
Circuit Breaker Analyzers & Timers
CAT Handheld Series
-
When it’s not practical to use conventional robust circuit breaker analyzers, a handheld circuit breaker analyzer and timer may come handy. DV Power has developed a unique CAT Handheld series. It is specially designed for testing of circuit breakers with one break per phase. Their compact and ergonomic design can provide a wide range of features and reliable operations in low, medium and high-voltage substations or in industrial environments.CAT Handheld series consists of two models, CAT-P and CAT-H. Both of them have a large (5,7 in) colored touch screen display. Because of that, test results are visible in dark places as well as in bright sunlight.Powerful internal Li-Ion battery of the instruments can last up to 8 hours of testing without recharging.CAT Handheld series records:main contacts operating times,contact synchronization,sequence time,a resistance of pre-insertion resistors,open and close coil currents,main contacts bounce time,auxiliary contact time,DC Voltage.Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by triggering signal from current clamps connected to circuit breaker coil.CAT-H is capable of performing a coil control, while this feature is optional at CAT-P instrument. In contrast to CAT-H, CAT-P instrument can execute “First Trip” test.Both instruments display numerical and graphical results. Because of that, a user can easily overlay up to 4 records in the graphical form and make a quick on-site analysis of potential defects.A user can download test results to a PC via Bluetooth interface for more detailed analysis using DV Win software.
-
Product
Turns Ratio Testers
TRT Standard Series
-
When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.
-
Product
Circuit Breaker Analyzers & Timers
CAT Advanced Series
-
DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.
-
Product
Turns Ratio Testers
TRT Advanced Series
-
TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.