IBEKO Power AB
Our goal is to always keep providing the world market with the most advanced test solutions for transformers, circuit breakers and batteries
- +1 800 599 8113
+46 70 0925 000 - +46 8 731 77 99
- support@dv-power.com
- sales@dv-power.com
- Box 1346
Lidingö, 181 25
Sweden
-
Product
Battery Chargers
BAC Series
-
Battery charger BAC series is a portable and universal battery charging solution. It is primarily intended for charging Lead-Acid, Ni-Cd and Li-ion batteries from 1 V DC to 300V DC level. However, the unit can charge the string of any battery type by one of the available charge modes:IU (constant current + constant voltage)UU (constant voltage + constant voltage with a current limit)Charging modes provide a safe regulation of charging procedure and achieves fast recharge and low risk of overcharge.Variety of implemented protections, such as thermal, overcurrent, undervoltage, and overvoltage, assure the charging process will be safe for the battery and the instrument itself.A user doesn’t have to switch off the main charger in order to use BAC series charger. Just the opposite, the BAC series charger should support the main charger to speed up the process. An alternative use is to quickly recharge a battery following a discharge test.The provided display enables users to monitor all relevant information during the charging process and to adjust charging parameters and limits in real-time.The instrument offers the best power-to-weight ratio in the market, weighing only 10 kg / 22 lbs with the maximum output power of 2,7 kW.The maximum charging currents for lead-acid, Ni-Cd and Li-ion batteries, at various battery voltages, are presented in the brochure.
-
Product
Battery Chargers
-
Following a power outage, various power engineering objects such as power plants should operate on battery back-up systems. It is necessary that these batteries are being properly charged in order to compensate its energy loss and keep their voltage within the predefined limits. DV Power’s chargers are portable and universal battery charging solution. They are primarily intended for charging Lead-Acid, Ni-Cd and Li-ion batteries from 1 V DC to 300 V DC level.Charging modes provide a safe regulation of charging procedure and achieves fast recharge and low risk of overcharge. Variety of implemented protections, such as thermal, overcurrent, undervoltage and overvoltage, assure the charging process is safe for the battery and the charger itself.
-
Product
Circuit Breaker Analyzers & Timers
CAT Handheld Series
-
When it’s not practical to use conventional robust circuit breaker analyzers, a handheld circuit breaker analyzer and timer may come handy. DV Power has developed a unique CAT Handheld series. It is specially designed for testing of circuit breakers with one break per phase. Their compact and ergonomic design can provide a wide range of features and reliable operations in low, medium and high-voltage substations or in industrial environments.CAT Handheld series consists of two models, CAT-P and CAT-H. Both of them have a large (5,7 in) colored touch screen display. Because of that, test results are visible in dark places as well as in bright sunlight.Powerful internal Li-Ion battery of the instruments can last up to 8 hours of testing without recharging.CAT Handheld series records:main contacts operating times,contact synchronization,sequence time,a resistance of pre-insertion resistors,open and close coil currents,main contacts bounce time,auxiliary contact time,DC Voltage.Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by triggering signal from current clamps connected to circuit breaker coil.CAT-H is capable of performing a coil control, while this feature is optional at CAT-P instrument. In contrast to CAT-H, CAT-P instrument can execute “First Trip” test.Both instruments display numerical and graphical results. Because of that, a user can easily overlay up to 4 records in the graphical form and make a quick on-site analysis of potential defects.A user can download test results to a PC via Bluetooth interface for more detailed analysis using DV Win software.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
-
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
Product
Circuit Breaker Analyzers & Timers
-
CAT circuit breaker analyzers and timers are advanced standalone or a PC controlled instruments for circuit breaker maintenance. Typical application areas of CAT instruments are medium and high voltage substations at electric power generation, transmission, and factories of switchgear. Also, industrial environments and electric power distribution are suitable application areas for these circuit breaker testing instruments.DV Power CAT circuit breaker testing instruments are portable and lightweight. They are designed for performing mechanical operations intended for circuit breakers testing according to standards IEC 62271-100 and IEEE C37.09.These instruments measure:the timing of main contacts, pre-insertion resistor contacts, auxiliary contacts operations,coil currents,motion parameters,voltage recording,main circuit resistance,arcing contacts wipe,and any relevant analog signal.Motion transducer channels provide measuring a displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time, and average velocity. Even more, CAT circuit breaker analyzer optionally has a built-in micro-ohmmeter. Hence, it provides the main circuit resistance measurement and dynamic resistance measurement. Dynamic resistance measurement is an effective method for arcing contacts condition assessment.
-
Product
Turns Ratio Testers
TRT Standard Series
-
When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.
-
Product
Battery Extra Load Units
BXL Series
-
BXL is an extra load unit designed to be used with DV Power’s BLU series battery testers. However, this unit is a universal add-on device. Because of that, it is compatible, as an additional load, with any other discharge/capacity tester in the market.In case when discharge current exceeds the capacity of a single BLU device, BXL can increase the discharge capacity. There are no limitations on the number of extra load units that can be connected in parallel to the main battery tester.A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way. Also, all instruments are in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.These units can be used on any type of battery string, such as lead-acid, Li-Ion, Ni-Cd, etc. They test battery strings with voltages in the range of 5,25 – 500 V DC. On the other hand, current up to 250 A can be discharged through the BXL internal structure.The instrument simulates a constant resistance load during the discharge test. Several resistances can be set for different battery nominal voltage levels. This makes BXL extremely flexible in selecting its load capabilities.
-
Product
Micro-Ohmmeters
-
Contact resistance measurement is one of the most important and common tests during switchgear manufacturing, commissioning and maintenance stages. Besides switchgear testing, the RMO digital micro-ohmmeters are designed for simple, safe and efficient testing of:disconnecting switches,high-current bus bar joints,cable splices,welding joints,and different high-current links in factory and high-induction field environments.All DV Power RMO micro-ohmmeters use Kelvin’s 4-point measurement principle which is the most convenient for very small resistance measurements. The measurements are accurate and in accordance with international standards for AC high-voltage circuit breakers testing (IEEE C37.09 and IEC 62271-100).Starting from 2003, DV Power has been a trend-setter on the market when our first 500 A micro-ohmmeter weighing only 8 kg (RMO500A / CPM500) was released.Currently, DV Power products portfolio includes 16 models, divided into 3 series:13 portable models: RMO-A (6) and RMO-G (7) series.6 handheld models: RMO-H (6) seriesThe instruments generate a user-selectable and ripple-free test current up to 800 A in an automatically regulated test ramp. Test current ramping significantly decreases the influence of the magnetic transients to measurement.
-
Product
Protective Bonding Testers
RMO-E Series
-
The RMO-E instruments are designed and ideal for testing protective bonding (grounding) of equipment following the standard IEC 61010-1. Also, they can measure the resistance of high, middle and low voltage circuit breakers, high-current bus bar joints, cable splices, and welding joints. The instruments accurately measure not only in factory environments but also in high-induction fields and substations.Both models generate a true DC ripple-free (less than 1 %) current with automatically regulated test ramps. During a test, the protective bonding testers automatically generate increasing current before measuring and decreasing current after the measurement. Consequently, this significantly decreases magnetic transients and ensures great accuracy.These instruments can store up to 500 measurements in the internal memory and have a built-in thermal printer available as an option.DV Win software communicates with the RMO-E earth resistance meter via USB or RS232 interface. It allows a user to run the test remotely from PC, as well as to download test results, analyze and generate fully configurable test reports.The RMO-E series contains two models, RMO60E and RMO100E. The main difference between these two models is in the maximal test current:60 A DC for RMO60E100 A DC for RMO100E
-
Product
Circuit Breaker Analyzers & Timers
CAT Standard Series
-
Circuit breakers are being tested during manufacturing, commissioning or maintenance stages. The most basic test requires timing measurement using circuit breaker timer. Their primary role is timing and motion measurement of medium and high voltage circuit breakers. Devices from CAT Standard series have suitable application in:electric power generation,distribution system,part of the electric power transmission system,contractors testing,and industrial environments.CAT Standard series meets the requirements of an easy to use circuit breaker timer and analyzer with an attractive price. Furthermore, they are portable and lightweight (weighs only up to 7 kg). Finally, the plastic case is unbreakable and has IP67 protective rating when the lid is closed.CAT Standard series includes five models:Three circuit breaker timers – CAT03, CAT31, and CAT61Two circuit breaker analyzers – CAT34 and CAT64CAT03 is a basic model intended only for timing measurement of main contact operations on the circuit breaker with one break per phase. Unlike CAT03, CAT31 has the possibility of circuit breaker operation initiation, coil current measurement, and auxiliary contact timing measurement. CAT61 differs in comparison to CAT31 by its ability to measure up to two breaks per phase.CAT34 and CAT64 are more advanced compared to CAT31 and CAT61, respectively, since they have additional analog channels. Also, they have the possibility of a travel curve recording.A user can download the test results to a USB memory stick or save it to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Optional thermal printer prints test results in tabular and graphical form on 80 mm (3.15 inch) paper rolls. CAT Standard series instruments are compatible with DV-Win software. It provides full control of all CAT functions from a PC, as well as acquisition and analysis of test results.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
-
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
Product
Three-Phase Transformer Demagnetizer
DEM60C
-
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
Product
Battery Extra Load Units
-
Performing capacity/discharge test on a high-capacity battery may be challenging since high requirements are set on the discharge system. In cases when discharge test times need to be reduced, high load capacities are required from the discharge system. The battery extra load unit BXL is an additional load unit designed especially for this purpose.It is primarily used with BLU battery testers. However, the unit is a universal add-on device. This means it can be used as an additional load with any other discharge/capacity tester in the market.When discharge current exceeds the capacity of a single BLU device, extra load unit increases discharge capacity. A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way in accordance to battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.
-
Product
Motor/Generator Test Equipment
-
Winding ohmmeters RMO-M series measure winding resistance of inductive test objects such as electrical motors and generators. Motor test or generator test of winding resistance is especially important for early-stage failure detection.RMO-M series instruments generate true DC ripple-free current with automatically regulated measurement and discharge process. Even more, test instruments are portable and enclosed in a metal casing.Applications supported by DV Power motor/generator test equipment include:Winding resistance measurement of generators and electrical motorsResistance measurement of high-current bus bar jointsResistance measurement of cable splicesAll of the above-mentioned measurements are performed with the highest accuracy. The advanced DV-Win PC software enables collecting both numerical and graphical results. These features provide an easier and more efficient analysis. After the test, a DV-Win software generates a test report a single click. Finally, a user can easily customize the report and save it in different formats, such as XLS and PDF.
-
Product
Transformer Turns Ratio Testers
-
Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.