IBEKO Power AB
Our goal is to always keep providing the world market with the most advanced test solutions for transformers, circuit breakers and batteries
- +1 800 599 8113
+46 70 0925 000 - +46 8 731 77 99
- support@dv-power.com
- sales@dv-power.com
- Box 1346
Lidingö, 181 25
Sweden
Battery Capacity Testers
determine the condition of batteries to provide power.
See Also: Battery Testers, Battery Checkers, Lead Acid Battery Testers, Battery Conductance Testers, Battery Load Testers
-
Product
Battery Capacity Testers|Discharge Testers
-
DV Power offers a wide range of battery capacity testers to meet specific customer needs. All of them are portable, powerful and most of all universal. Any battery string, such as lead-acid, lithium-ion, nickel-cadmium based and others, with voltages in the range of 0,9 – 800 V DC can be tested in an accurate, user-friendly way.The capacity test is carried out following the battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.BLU battery testers enable setting the discharge current up to 350 A, with 0,1 A resolution. If higher currents are required, several units can be connected in parallel, or BXL additional load units can be used. Discharge parameters can be monitored in real-time during the capacity test. Overall battery voltage, current, elapsed test time and capacity will be presented during the entire test on a touch screen display.
-
Product
Battery Capacity Tester
BLU-T Series
-
Battery load bank BLU-T is a powerful and lightweight solution designed for condition assessment of telecommunication and radio equipment backup supply. This instrument can perform the battery capacity test on battery strings such as Pb, Li-ion, Ni-Cd, and others. It tests battery strings with voltages in the range of 0,9 – 70,5 V DC. As a special feature, the BLU110T model enables capacity testing of single PB, Ni-based as well as Li cells (with current up to 100 A).The capacity test is conducted in an accurate, user-friendly way. Also, it is in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.BLU-T battery load bank enables setting the discharge current up to 350 A, with 0,1 A resolution. If higher currents are required, the BLU-T units can be connected in parallel, or BXL-T additional load units can be linked.The instrument offers a high power-to-weight ratio. BLU-T series has models starting from 12,8 kg / 28.2 lbs and up to 19,2 kW of power.A user can select one of three discharge modes: Constant current, Constant power, Constant resistance. Additionally, different battery duty cycles can be simulated using user-selectable discharge profiles.Discharge parameters can be monitored in real-time during the capacity test. A 4,3-inch touch screen shows overall battery voltage, discharge current, discharge test time and capacity during the entire test. Also, the capacity tester is compatible with DV-B Win software. A user can view a detailed numerical and graphical presentation of key parameters, and create reports in various formats.Testing can be carried out without disconnecting the battery from the service.
-
Product
Battery Capacity Tester
BLU-A Series
-
The battery capacity test is performed to determine the health of a battery. DV Power’s battery load unit BLU-A is a portable, powerful, and lightweight solution for battery capacity measurement. It is applicable to any battery string such as lead-acid, Li-Ion, Ni-Cd, etc., with up to 500 V battery voltage. As a special feature, BLU100L model enables the capacity testing of a single Li-Ion cell.The capacity test is performed in an accurate and user-friendly way. Also, it is in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.Battery load unit BLU-A enables setting discharge currents up to 240 A, with a resolution 0,1 A. Furthermore, if higher currents are required, BLU-A units can be connected in parallel, or additional BXL load units can be used.The instrument offers the best power-to-weight ratio in the market. BLU-A models start from 12,8 kg / 28.2 lbs and deliver up to 28,4 kW of power.The user can select three discharge modes:Constant current,Constant power,Constant resistance.Additionally, different battery duty cycles can be simulated using user-selectable discharge profiles.The instrument monitors discharge parameters in real-time during the capacity test. A 4,3-inch touch screen display shows battery voltage, current, elapsed time, and capacity during the entire test. Also, BLU battery load unit can be used with DV-B Win software. As a result of that, a user can see a detailed numerical and graphical presentation of key parameters and can create reports in various formats.Testing with BLU-A doesn’t require a disconnection of the battery from the testing equipment.
-
Product
Battery Capacity Tester
BLU-C Series
-
BLU-C is the latest solution from DV Power for conducting a comprehensive battery capacity test. This universal instrument is applicable to any battery string, such as lead-acid, Li-Ion, Ni-Cd, and others, with voltages up to 800 V DC.BLU-C tester simplifies battery testing in multiple ways. The instrument provides monitoring of discharge parameters (graphically and numerically) in real-time on a 7-inch touch screen display. The instrument also enables measurement and monitoring of cell parameters (voltage/intercell voltage/temperature), which makes it a complete stand-alone discharge test system.The capacity tester is compatible with DV-B Win software. Because of that, the user can view detailed numerical and graphical presentations of key parameters, and create reports in various formats.The capacity test is performed in a user-friendly way according to battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22 and other.The battery tester enables setting the discharge current up to 300 A, with 0,1 A resolution. If higher currents are required, BLU-C units can be connected in parallel, or BXL additional load units can be used.The user can select one of three discharge modes: Constant current, Constant power, Constant resistance. Additionally, different battery duty cycles can be simulated using user-selectable discharge profiles.Testing can be carried out without disconnecting the battery from the equipment it supplies.
-
Product
Battery Chargers
-
Following a power outage, various power engineering objects such as power plants should operate on battery back-up systems. It is necessary that these batteries are being properly charged in order to compensate its energy loss and keep their voltage within the predefined limits. DV Power’s chargers are portable and universal battery charging solution. They are primarily intended for charging Lead-Acid, Ni-Cd and Li-ion batteries from 1 V DC to 300 V DC level.Charging modes provide a safe regulation of charging procedure and achieves fast recharge and low risk of overcharge. Variety of implemented protections, such as thermal, overcurrent, undervoltage and overvoltage, assure the charging process is safe for the battery and the charger itself.
-
Product
Battery Supervisors
-
DV Power manufactures ideal tools for maintenance, troubleshooting and performance tests on stationary batteries.Capacity testing is performed in order to detect which cells in the string should be replaced by measuring a cell voltage, temperature, inter-cell connection voltage, and specific gravity.IEEE standards for stationary battery applications also stipulate measuring these key parameters during periodic battery inspections.DV Power provides two types of instruments:BVS series – for automated monitoring of battery parametersBVR series – for manual monitoring of battery parametersIn contrast to BVS, BVR instruments can be used for the transfer of electrolyte specific gravity measurements from a density meter (DMA35) via Bluetooth. This provides a more extensive analysis of each cell in the tested battery string.
-
Product
Battery Chargers
BAC Series
-
Battery charger BAC series is a portable and universal battery charging solution. It is primarily intended for charging Lead-Acid, Ni-Cd and Li-ion batteries from 1 V DC to 300V DC level. However, the unit can charge the string of any battery type by one of the available charge modes:IU (constant current + constant voltage)UU (constant voltage + constant voltage with a current limit)Charging modes provide a safe regulation of charging procedure and achieves fast recharge and low risk of overcharge.Variety of implemented protections, such as thermal, overcurrent, undervoltage, and overvoltage, assure the charging process will be safe for the battery and the instrument itself.A user doesn’t have to switch off the main charger in order to use BAC series charger. Just the opposite, the BAC series charger should support the main charger to speed up the process. An alternative use is to quickly recharge a battery following a discharge test.The provided display enables users to monitor all relevant information during the charging process and to adjust charging parameters and limits in real-time.The instrument offers the best power-to-weight ratio in the market, weighing only 10 kg / 22 lbs with the maximum output power of 2,7 kW.The maximum charging currents for lead-acid, Ni-Cd and Li-ion batteries, at various battery voltages, are presented in the brochure.
-
Product
Ground Grid Tester
GGT Series
-
The GGT500 ground grid integrity tester is designed for inspection of the substation ground grid. It can also be used as a portable micro-ohmmeter with Both Sides Grounded and Remote Control functionalities. It is intended to inspection the conditions of a grounding system beneath substations, testing of medium- and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links.In the United States when inspecting the quality of the grounding systems beneath a substation, the proper procedure is to inject 300 A DC during a time period of 60 s. This is what the GGT500 will do, and in that time period, the current path and voltage drop are checked. Also acting as a micro-ohmmeter, the GGT500 can test low resistance values by producing high test currents of up to 500 A.The instrument is placed in an unbreakable, plastic case with IP67 protective rating (with closed lid). Although very portable and lightweight, micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents, as well as the use of thinner/longer test cables. GGT500 ground grid integrity tester generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. This significantly decreases magnetic transients and ensures great accuracy.When used for testing in Both Sides Grounded conditions, a special current clamp powered from the ground grid integrity tester is used for measuring a current through groundings. If even a higher safety level is required, the remote control feature enables the operator to perform measurements from a distant location, away from the instrument and test object.
-
Product
Battery Extra Load Units
-
Performing capacity/discharge test on a high-capacity battery may be challenging since high requirements are set on the discharge system. In cases when discharge test times need to be reduced, high load capacities are required from the discharge system. The battery extra load unit BXL is an additional load unit designed especially for this purpose.It is primarily used with BLU battery testers. However, the unit is a universal add-on device. This means it can be used as an additional load with any other discharge/capacity tester in the market.When discharge current exceeds the capacity of a single BLU device, extra load unit increases discharge capacity. A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way in accordance to battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.
-
Product
Battery Test Equipment
-
Improper functioning of battery systems installed in utilities, power plants, telecommunication systems, industrial applications and etc., can cause severe failures of the supported equipment and loss of critical information. Therefore, the battery test verifies their actual SOC (State of Charge) or SOH (State of Health) and prevents unwanted scenarios which could result in a significant budget loss as well as endanger of human lives.DV Power battery test equipment is able to perform the following battery measurements, using BLU and BVR devices:- Voltage (String and Cell)- Capacity- Temperature- Density of electrolyteAll of the above-mentioned measurements are performed with the highest accuracy. The advanced DV-B Win PC software enables collecting both numerical and graphical results. These features provide an easier and more efficient analysis. After the test, DV Win software generates a test report with a single click. A user can easily customize the report and save it in different formats, such as CLS, PDF, Word, or RTF.
-
Product
Battery Voltage Supervisor
BVS
-
DV Power battery voltage supervisor – BVS, is an accurate battery voltage monitoring system that monitors the state of health of battery systems. It records important battery parameters such as battery voltage, inter-cell connection voltage, and ambient temperature. Because of that, it can be a support tool for capacity testing.The BVS voltage supervisor is an integrated system consisting of:BVS Control Unit (BVS-CU)Cell Voltage Modules (CVM)String Voltage Module (SVM) (optional)String Current Module (SCM) (optional)It is an ideal testing tool for maintenance, troubleshooting and performance tests on individual stationary batteries and battery packs in critical backup energy solutions.BVS-CU provides ambient temperature measurements on multiple locations (4 temperature channels). Overall string voltage and string current monitoring can be achieved by using an optional string voltage module (SVM) and string current module (SCM).There are two types of DV Power battery voltage supervisors:BVS – One cell voltage module measures 1 cellBVS-4 – One cell voltage module measures 4 cellsCVM modules detect cells that fail a discharge test based on monitored voltage values. As a result of that, these cells can be safely removed from the battery string.Data acquisition and analysis of data collected from the modules are available in the DV-B Win application software suite. They provide data viewing, tracking, and generation of comprehensive reports.
-
Product
Coil Testers & Power Supplies
POB Series
-
Coil testers and power supply units, models POB30 and POB40 are ideal for commissioning and maintenance testing of circuit breakers. The station supply is not available. The POB series are power supply units implementing the latest power electronics technology. They are developed for use in switchyards, power and industrial environment. In addition to providing current and voltage for breaker testing, they can measure certain coil parameters.
-
Product
Battery Voltage Recorder
BVR Series
-
Battery voltage recorders from BVR series are designed to serve as a support tool for cell voltage measurement during battery capacity testing.During capacity testing, cell voltage, temperature, inter-cell connection voltage, and specific gravity should be measured in order to determine failling cells in the string that should be replaced.Furthermore, IEEE standards for stationary batteries applications stipulate periodical measurement of overall string voltage, as well as cell voltage and temperature.The BVR Series is the perfect tool for that purpose. All measurements are automatically saved in device’s internal memory. Additionally, DV-B Win software helps the user to download all measured results. Furthermore, the user can create test reports and export them to various formats.BVR series includes two models: BVR11 and BVR22. These are rechargeable handheld devices intended for performing monthly battery inspections and support tools during capacity testing. The list of the applications of these instruments includes:Efficient supplement to BLU series of battery load units during battery discharge testingMonthly inspections of large battery banksAmbient temperature measurementCurrent measurement using current clampsUSB and Bluetooth communication with PCSimultaneous string voltage and current measurement to analyze a discharge test processThe BVR22 model provides Bluetooth communication with an external density meter, for transferring electrolyte specific gravity and temperature readings.
-
Product
Turns Ratio Testers
TRT Standard Series
-
When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.
-
Product
Handheld Turns Ratio & Winding Resistance Tester
TWR-H Series
-
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.















