Sound Sources
More Info| Related Searches: | Audio Signal Sources, Sound Calibrators |
|---|---|
| Expand Your Results: | Acoustics, Sound, Sources |
-
FP120 Sound pressure source CESVA Instruments, SL Contact Info Send To Colleague This unit consists of a noise generator (AP600) and an omnidirectional source (BP012) with 12 loudspeakers mounted on a dodecahedral housing. Required in Insulation measurements, RT etc. APPLICATIONS:Measurement of sound insulation in buildings and of building elements, Room Reverberation Time measurements, measurement of sound absorption in a reve ...more -
Model 402H Microphone Calibrator Trig-Tek Contact Info Send To Colleague The Trig-Tek, Inc. Model 402H Microphone Calibrator is a portable, self contained, high intensity acoustic microphone calibration source. Its portable hand held sound transducer combined with a 25 foot cable allows access to permanetly mounted or remotely located transducers. Its portable carrying case is modified to provide storage of all ext ...more -
Nor140 - Sound Analyser Norsonic Contact Info Send To Colleague Sound recording. Environmental noise. Building acoustics. Noise source identification. Industrial hygiene. Product development. Quality control. Noise mapping. Sound power. Speech intelligibility - STIPA. Vibration measurements ...more -
HD 9101 - HD 9102 Sound Level Meters Delta OHM S.r.L. Contact Info Send To Colleague Battery fed portable sound source, suitable for calibrating sound level meters and acousitc measuring stations. ...more -
NTI TalkBox - Acoustical STI-PA Reference Neutrik Test Instruments Contact Info Send To Colleague NTI TalkBox greatly simplifies the acoustical feed of the STI-PA intelligibility test source signal into closed sound reinforcement systems. It presents the standardized voice-like acoustical signal emission simulating a human talker according to IEC 60268-16, combined with a TNO certified speech intelligibility signal at standardized levels. ...more -
Mid-Frequency Volume Source VSS210 BSWA Technology Co., Ltd. Contact Info Send To Colleague VSS210 Volume Source is a mid-frequency volume source. It is ideal acoustical source for reciprocity measurements and TPA analysis. VSS210 uses a power speaker driver to deliver up to 125 dB over the frequency range from 200 to 10,000 Hz. Two phase matched MPA416 microphones is installed at 2 cm apart in the outlet. The microphones provide the sou ...more -
Sound Power Solution OROS Contact Info Send To Colleague The Sound Power Solution is part of the family of solutions proposed by OROS for Acoustic applications. This Solution allows to measure Sound Power based on the measurement of sound pressure levels at microphone positions around a source under test. Thus, the Sound Power Solution is complementary of the Sound Intensity Solution that is based o ...more -
NC-72 Pistonphone Reference Sound Source RION Co., Ltd. Contact Info Send To Colleague Portable sound source for calibration of Sound level meters and sound measuring system. Sound pressure level: 114 dB ± 0.2 dB. Frequency: 250 Hz ± 1 %. Standard sound source for laboratory studies. ...more -
SPM9613 Community Noise Prediction Software, Version 2 Power Acoustics, Inc. Contact Info Send To Colleague a low-cost computer program for analyzing community noise and sound propagation emitted from a variety of noise sources. The engineering software is based on the ISO 9613 parts 1 and 2 standards. SPM9613 provides calculations at specific field points (listeners) and predictions of A- and C-weighted sound level contours as well. ...more -
MF720/710 MICROPHONE SPHERICAL SURFACE FIXTURE BSWA Technology Co., Ltd. Contact Info Send To Colleague In the measurement of sound power level according to ISO 3745-2003, 20 measurement positions are required on a spherical measurement surface enveloping a noise source in anechoic and hemi-anechoic room. However, it is difficult to mount 20 microphones on tripods in a spherical surface. ...more -
STARAcoustic Spectral Dynamics, Inc. Contact Info Send To Colleague STARAcoustics is a complete acoustic intensity program for use with multi-channel FFT instruments or real-time octave analyzers and microphone probes. Acoustic intensity analysis enables you to: Quickly identify noise sources. Accurately determine the sound power radiating from noise sources. Acquire measurements in acoustically noisy environments ...more -
ST-NG1 White & Pink Noise Generator Radio Design Labs Contact Info Send To Colleague The ST-NG1 is the ideal choice where random white or pink noise is needed. It is suitable either as a reference noise source for audio measurements or as a masking noise source in engineered sound or counter-intelligence applications. ...more -
ULD500 - Ultrasonic Leak Detector General Tools & Instruments Co., LL Contact Info Send To Colleague Ideal for detecting and locating sources of ultrasonic sound through the use of sophisticated electronic circuitry. Unaffected by audible noise allowing for use in extremely noisy environments. Designed to detect ultrasound at 40.5kHz, not even a murmur will escape detection ...more -
7816 Acoustic Determinator Brüel & Kjær Contact Info Send To Colleague Acoustic Determinator Type 7816 is a very convenient and intuitive tool for acoustic engineers who want to find out the sound power level of industrial sources by measuring sound pressure levels in the field. Using data from field measurements, ...more -
Sound Power Brüel & Kjær Contact Info Send To Colleague Sound Power has become the preferred quantity to measure when determining product noise emissions. This is because it is an absolute quantity, dependent only on the noise source itself, and independent of the acoustic environment. Sound Pressure, on the other hand, is dependent on both the noise source and on the acoustic environment. ...more -
Class 1 Leq Sound Level Meter Kit Castle Group Ltd. Contact Info Send To Colleague The simple handy package for running noise assessments, checking noise levels and performing personal noise exposure levels. Check noise levels in the workplace, environment, pub or club. Ensure that employees and anyone near a noise source is not being subjected to noise levels above dangerous noise levels. ...more -
Probe microphone Type 40SA GRAS Contact Info Send To Colleague The Probe Microphone type 40SA is a small, compact unit for sound pressure measurements in small enclosures, in harsh environments and very close to sound sources. The high acoustic input impedance of the probe tip minimises the influence on the acoustic field, while the stainless steel probe tube (the 160 mm tip) can withstand temperatures of 800 ...more -
NI LabVIEW Order Analysis Toolkit National Instruments Contact Info Send To Colleague LabVIEW Tools for Order Tracking, Analysis, and Extraction - Order analysis is a tool for examining dynamic signals generated by mechanical systems that include rotating or reciprocating components. As with frequency-domain analysis, you can think of order analysis as a signal scalpel that can dissect sound, vibration, and other dynamic signals int ...more -
05000 Sound Level Calibrator Metra Mess- und Frequenztechnik in Radebeul e.K. Contact Info Send To Colleague Calibration sound source for microphones and sound measuring systems. Sound pressure level: 94 dB (1 Pa). Frequency: 1000 Hz. ...more -
4295 OmniSource Loudspeaker Brüel & Kjær Contact Info Send To Colleague For most building acoustics measurements, the sound source must radiate sound evenly in all directions to give reproducible and reliable results. Hence the relevant standards for the measurement of building acoustics (ISO 140 and ISO 3382) require that an omnidirectional sound source be used. ...more -
4292 OmniPower Sound Source Brüel & Kjær Contact Info Send To Colleague For most building acoustics measurements, the sound source must radiate sound evenly in all directions to give reproducible and reliable results. Hence the relevant standards for the measurement of building acoustics (ISO 140 and ISO 3382) require that an omnidirectional sound source be used. ...more -
Pistonphone Type 42AP GRAS Contact Info Send To Colleague he G.R.A.S. Pistonphone Type 42AP is a battery-operated, precision sound source for accurate and reliable calibration of measurement microphones, sound level meters and other sound measuring equipment. ...more -
2716 Power Amplifier Brüel & Kjær Contact Info Send To Colleague Power Amplifier Type 2716 has two channels which may be used independently or jointly (using the Link A+B and Phase Reverse B switches). Input level requirements are matched by those signals generated by Investigator Type 2260D. Total output power is in the order of 300 W and is relatively independent of load; this matches the requirements for ...more
- Pages:
- 1
|
Definition: Standard for calibrating sound level meters and sound measuring systems. |