High Voltage Probes
handle voltages beyond general purpose passive probes and operate in the range >500 volts and <20,000 volts.
See Also: High Voltage Meters
- Pickering Interfaces Inc.
product
PXI 8-Slot High Density 2A BRIC Matrix, 232x8 2-Pole (8 Sub-cards)
40-573-102-232X8
The 40-573-102-232x8 BRIC is part of a range of high density matrix modules able to switch up to 2 A at 240 VDC/250 VAC. They are available in 2, 4 or 8-slot sizes to suit most high performance matrix requirements, constructed using quality electromechanical relays for high switching confidence.
-
product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP023-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscillosco...show more -
product
Insulation Resistance Tester For PV (4 Range)
MIS-PV2
MULTI MEASURING INSTRUMENTS Co., Ltd.
The model MIS-PV2 is an insulation resistance tester for the exclusive use in photovoltaic systems. The ordinary insulation resistance testers cannot make measurement properly during generation of PV systems. This instrument, however, can measure the insulation resistance simply by touching probe to the live line whether making generation or not. There are two ranges of PVH and PVL. PVH is for high voltage generation system (more than 500V and less than 1000V) and PVL is for the system less than 500V.
-
product
Hi-Z HV AC Voltmeters
B-1013
*25kV, 50kV or 100kV Meter with integral line to ground Probe*Phasing or line to line with additional Probe*Optional 6ft or 9ft Collapsible Hotsticks*Voltage source for testing Voltmeters and Probes*Optional test point contamination indicating Megmeter®*High voltage cable clamps or hooks*Heavy duty carrying case
-
product
Differential Voltage Probes
DP150/DP200pro
The DP differential isolation probes are an important accessory for any laboratory involved in power electronics and high voltage systems. These probes allow isolated and floating measurements with any oscilloscope or data recorder, whilst the oscilloscope can remain grounded. Using a DP150 or DP200pro probe, differential and floating measurements can be made on a variety of ac power systems like 230V/110V ac input power supplies, chopped and switching power supplies, thyristor controllers, var...show more -
product
T3 Low & High Voltage Differential Probes
T3 Series
Teledyne Test Tools Low & High Voltage Differential Probes offer end user versatility with all models powered by an external universal power supply and work with any Oscilloscope with a high-impedance BNC input. The range consists of one Low Voltage and three High Voltage models with varying bandwidths to satisfy a wide array of customer applications.
-
product
Field thermal needle system for thermal resistivity / conductivity measurement
FTN01
Hukseflux Thermal Sensors B.V.
The FTN01 Field Thermal Needle System allows performing fast, on-site measurements of the thermal resistivity or conductivity of soils, in particular around the typical depth of burial of high voltage cables. FTN01 is designed with a focus on robustness and saving time, while still offering sufficient accuracy for typical field measurements. The sensor is a Non-Steady-State Probe (NSSP), TP09, which is mounted at the tip of the Lance LN01. The system is operated using a hand-held Control and Readout Unit CRU01.
-
product
Injection Transformer
J2101A
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
product
Replacement Pincer Clips for High Voltage Differential Probe
PK-HVA-02
Replacement Pincer Clips for High Voltage Differential Probe
-
product
Low Voltage Single Ended Probes
A low voltage single-ended probe is typically used for measuring high-speed, ground referenced signals up to 12 V. These low voltage probes are the best choice for making measurements on high impedance, high frequency circuit elements which require minimal probe loading. Users should select probes with a low input capacitance specification (~1 pF) to minimize the probe’s loading effect on the circuit. A probe with lower input capacitance will offer higher input impedance at higher frequencies.
-
product
10:1 500 MHz 10 MOhms Passive Probe
PP005A
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MO. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
High Voltage Probe: Single-Ended
A high voltage single-ended probe is typically used for measuring ground referenced signals up to 40 kV. However, some single-ended probes are designed for oscilloscopes with isolated or floating inputs for measurements that are not ground referenced. Users should select probes with a low input capacitance specification (< 4 pF) to minimize the probe’s loading effect on the circuit because a probe with lower input capacitance will offer higher input impedance at higher frequencies.
-
product
1kV, 120 MHz High Voltage Differential Probe Without Tip Accessories and with Auto Zero Disconnect
HVD3106A-NOACC
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
High Voltage Fiber Optic Probe, 150 MHz Bandwidth
HVFO108
- Ideal for GaN and SiC devices- Highest system accuracy- Fastest rise time- High CMRR - 160 dB
-
product
High Voltage Differential Probe
DP750-100
Shenzhen Micsig Instruments Co., Ltd.
*The leads and probe are with shielded design, interface ends are integrated in a compact box, no need to twist the cables, leads to a lower noise floor and has less interference. *Support one-press Zero calibration and automatic overrange alarm.*Directly powered by Micsig UPI interface, realise auto scaling setup, can also powered by oscilloscope via USB cable.
-
product
Acute High Voltage Differential Probe, 50x/500x, 25MHz, 3500V
ADP5025
*USB Powered (or Power Bank)*Bandwidth up to 25 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
product
High-Voltage Differential Probe, 200 MHz
N2805A
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.
-
product
Low & High Voltage Differential Probes
T3
Teledyne Test Tools Low & High Voltage Differential Probes offer end user versatility with all models powered by an external universal power supply and work with any Oscilloscope with a high-impedance BNC input. The range consists of one Low Voltage and three High Voltage models with varying bandwidths to satisfy a wide array of customer applications.
-
product
High Voltage Optically Isolated Probes
High Voltage Optically Isolated Probes are designed to aid in device characterization measurements. Whether it is low or high voltage signals sitting on HV busses, high bandwidth, extreme precision, and optical isolation means floating measurements are easily made with minimal DUT loading.
-
product
Isolated Hall Effect Current Sensors
Isolated Hall Effect current sensors provide accurate high bandwidth current sensing. Vektrex offers models to 320A. For use, the 50-ohm voltage output is connected directly to an oscilloscope or data acquisition system. VCS sensors are magnetically isolated like clamp-on oscilloscope probes. With secure cable attachment, repeatability is ensured.
-
product
Circuit Tester
TE6-0720
Hangzhou Tonny Electric & Tools Co., Ltd.
*For use on cars, trucks, boats, trailers and motorcycles*Needle point probes *Use to trouble shoot both primary and secondary circuits*Use this tester to check primary circuits of 6/12V*On secondary or high voltage circuits you can check spark plugs
-
product
Battery Cell Formation System
17000 series
Chroma 17000 series is specifically designed for the formation of Lithium Ion and Lithium Polymer secondary batteries. The 17000 series is a complete turn-key system, including carrier trays, robust battery probe contacts, high quality charge/discharge modules and intuitive software all under computer control. Patented Battery Voltage Tracking (BVT) DC-DC conversion power modules minimize power consumption in battery charging, and Energy Recycle Modules (ERM) recycle the discharged energy direct...show more -
product
Differential Probe
With signals becoming faster, and power supply voltages going lower, these active differential probes will allow floating measurements from 100uVolts to as high as 7000 volts. These probes provide high CMRR and a broad frequency range.
-
product
Passive Probe, 500 MHz, 10:1, 1 MOhm/10 MOhm
PP020-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscillosco...show more -
product
High Voltage Probe, 100:1, 3.7 KVpk, 500 MHz
10076C
The Keysight 10076C 3.7 kVpk, 100:1 passive probe gives you the voltage and bandwidth you need for making high-voltage measurements. Its compact design makes it easier to probe today's small power electronics components, and its rugged construction means it can withstand rough handling without breaking.
-
product
Insulation Resistance Tester For PV (Judge Deterioration Point)
MIS-PVS
MULTI MEASURING INSTRUMENTS Co., Ltd.
The model MIS-PVS is an insulation resistance tester for the exclusive use in photovoltaic systems. The ordinary insulation resistance testers cannot make measurement properly during generation of PV systems. This instrument, however, can measure the insulation resistance simply by touching probe to the live line whether making generation or not. There are two ranges of PVH and PVL. PVH is for high voltage generation system (more than 500V and less than 1000V) and PVL is for the system less than 500V.
-
product
6kV High Voltage Passive Probe, 500 MHz
PPE6KV-A
High voltage single-ended passive probes are suitable for a wide range of applications where ground-referenced high-voltage measurements must be made safely and accurately. There is also a sense pin to automatically configure the oscilloscope for use with the probe.
-
product
1.5kV, 200 MHz, 2 pF, 10 M, Rise Time < 1.75 ns, High Voltage Differential Probe
T3HVD1500-200
1.5kV, 200 MHz, 2 pF, 10 M, Rise Time < 1.75 ns, High Voltage Differential Probe.
-
product
High Voltage Non-Contact Current Probe
P02-0802
The TESCO High Voltage Non-Contact Current Probe (Catalog No. P02-802) was developed using current sensor technology. It is a two-piece, True RMS ammeter with a fiber optic link between the high voltage sensor and the readout at ground potential. The sensor is mounted on a hotstick and slipped over a high voltage line.