High Voltage Probes
handle voltages beyond general purpose passive probes and operate in the range >500 volts and <20,000 volts.
See Also: High Voltage Meters
- Pickering Interfaces Inc.
product
PXI/PXIe High Density Precision Resistor Module
42-297A-014
The 40-297A-014 (PXI) and the 42-297A-014 (PXIe) are 18-channel programmable resistors with a range of 1 Ω to 470 Ω. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
product
Acute High Voltage Differential Probe, 20x/200x, 100MHz, 1400V
ADP2100
*USB Powered (or Power Bank)*Bandwidth up to 100 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
product
Power/Voltage Rail Probe. 4 GHz Bandwidth, 1.2x Attenuation, +/-30V Offset, +/-800mV
RP4030
The Teledyne LeCroy RP4030 Power Rail Probe meets the specific requirements of those who need to acquire a low-voltage DC signal as part of a:-Comprehensive power integrity, digital power management IC (PMIC), voltage regulator module (VMR), point-of-load (POL) switching regulator, or low-dropout regulator testing- Complete embedded power management system that includes PMICs, VRMs, POLs, and LDOsThe RP4030 will faithfully acquire a low-impedance, low-voltage DC power/voltage rail signal without unduly loading the device under test (DUT), while providing high offset to allow DC power/voltage rail signal display on an oscilloscope with high gain.
-
product
High Voltage Probe
HVP-39pro
* 39KVDC+ACpeak* 900MΩ Impedance* DC~50MHz(-3dB)* 1000:1 for Oscilloscope* Very Low Nosie
-
product
T3DSO Passive Probe, 350 MHz, 1X/10X, 1 MOhm/10 MOhm, 300V/600V
T3PP350
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
Acute High Voltage Differential Probe, 50x/500x, 100MHz, 3500V
ADP5100
*USB Powered (or Power Bank)*Bandwidth up to 100 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
product
÷10, 500 MHz, 10 MΩ, Passive Probe
PP009-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscillosco...show more -
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP026-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscillosco...show more -
product
÷10, 500 MHz, 10 MΩ, Passive Probe (Total of 1 Per Channel)
PP008-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscillosco...show more -
product
High Voltage Differential Probe
ADF25A
Permits conventional grounded oscilloscopes to be used for the display and measurement of multiple floating signals with high common mode voltages
-
product
Digital Teslameters/Gaussmeters
S Digital Teslameters offer accurate, high resolution measurement of magnetic flux densities, withdirect digital readout in tesla or gauss, and serialcommunications by fiber optics or RS-232C for system applications.The instruments are light and compact, and the probes are easy to use. The DTM-151 has been engineered to withstandthe severe electrical interference produced by high voltage discharge.
-
product
High Impedance Active Probes
12C
A high speed, high input impedance active probe for measuring the internal node voltage of integrated circuits. The input is 1 megohm shunted by 0.1 pf and the rise/fall times are 0.8 ns. This instrument has full dc capability and can be used with any oscilloscope. The Model 12C was specially designed so that when used in conjunction with a high input impedance oscilloscope, signal attenuation is 10:1 and with a 50 Ohm input, signal attenuation is 20:1.
-
product
T3DSO Passive Probe, 350 MHz, 10X, 10 MOhm, 300V/600V
T3PP350A
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
500 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP018-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscillosco...show more -
product
High Voltage Probe
HVP-40M
*DC 40KV CAT II Pollution 2*600MΩ Impedance*25KV ± 2%, 40KV ± 3%*T.C. 200 ppm/oC*Positive Polarity only.*Resolution 1KV*Need not power.*CE, TUV GS, UL, CUL, IEC1010
-
product
Acute High Voltage Differential Probe, 10x/100x, 100MHz, 700V
ADP1100
*USB Powered (or Power Bank)*Bandwidth up to 10 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
product
1kV, 25 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3102A
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
High Voltage Differential Probes
DP Series
Shenzhen Micsig Instruments Co., Ltd.
*Micsig DP Series High Voltage Differential Probes can be used with any brand of oscilloscope. *It adopts high-impedance isolation between the input and output to protect personal safety, converts the input high-voltage signal to a low-voltage signal for observation and analysis on oscilloscope.
-
product
High Voltage Probe
HVP-40
*MAX. Voltage : DC : 40KV, AC : 28KV, (50/60Hz only) CAT II.*1000MΩ Input Impedance.*Accuracy **DC: ± 1% to 20KV. ± 2% to 40KV. **AC: -5% to -10% (50/60Hz)*Division Ration : 1000:1*CE, TUV GS, UL, CUL, IEC1010
-
product
Circuit Tester
TE6-0720
Hangzhou Tonny Electric & Tools Co., Ltd.
*For use on cars, trucks, boats, trailers and motorcycles*Needle point probes *Use to trouble shoot both primary and secondary circuits*Use this tester to check primary circuits of 6/12V*On secondary or high voltage circuits you can check spark plugs
-
product
Active Voltage Rail Probe
Voltage rail probes are designed specifically to probe a 50 Ohm DC power/voltage rail. The probe has large built-in offset, low attenuation (noise), and high DC input impedance. Built-in offset and low attenuation permit the power/voltage rail to be offset in the oscilloscope by its mean DC voltage with high oscilloscope gain (sensitivity) to achieve a noise-free view of small signal variations. The high DC input impedance eliminates loading of the DC rail.
-
product
High Voltage Passive Probes
The PPE6KV-A and HVP120 can handle up to 6000 Vpeak transient overvoltages and are designed for probing up to 2000 Vrms and 1000 Vrms respectively. Fast rise times, excellent frequency response, and a variety of standard accessories make these probes safe and ideal for high voltage measurement applications
-
product
Probing Solutions
ES62X-CMPS
The ES62X-CMPS compact manual probe station is a rugged wafer probing solution designed for high reliability, compact size and low investment cost. It enables manual wafer level measurements up to 300 mm wafers. The probing station can also be used for TLP, HMM, HBM, LV-Surge, RF, S-parameter and DC-measurements. Micro positioners with vacuum as well as magnetic base can be attached. The chuck has a vacuum interface for the wafer and is electrically isolated. Multiple 4 mm connectors can be used to connect a voltage potential to the wafer backside.
-
product
High Voltage Optically Isolated Probe, 350 MHz Bandwidth. Includes soft-carrying case.
DL03-ISO
The DL-ISO enables highest confidence in GaN and SiC device characterization with highest accuracy, best signal fidelity, and comprehensive connectivity.
-
product
Passive Probe
ENVI
PMK Mess- und Kommunikationstechnik GmbH
The world's first modern probe for this high temperature range is suitable for a variety of applications with an input voltage range of 400V / 1250V peak, 10:1 divider and 350MHz bandwidth.The individual and signal-true contacting for different applications is guaranteed by the exchangeable spring tip and a variety of contacting accessories.
-
product
7kV, 100 MHz, 2.5 pF, 40 M, Rise Time < 3.5 ns, High Voltage Differential Probe
T3HVD7000-100
7kV, 100 MHz, 2.5 pF, 40 M, Rise Time < 3.5 ns, High Voltage Differential Probe.
-
product
DC-to-250MHz 1:100 Oscilloscope Probe Kit (HP-9258)
PRB-HP-9258
The Oscilloscope Probe 1:100 - HP-9258 is a low-input capacitance high voltage 1:100 oscilloscope probe with a bandwidth of 250 MHz designed and calibrated for use on scopes having an input impedance of 1 MOhm shunted by 20 pF. However, it may be compensated for use with oscilloscopes having an input capacitance of 10 - 35 pF.
-
product
Low Voltage Single Ended Probes
A low voltage single-ended probe is typically used for measuring high-speed, ground referenced signals up to 12 V. These low voltage probes are the best choice for making measurements on high impedance, high frequency circuit elements which require minimal probe loading. Users should select probes with a low input capacitance specification (~1 pF) to minimize the probe’s loading effect on the circuit. A probe with lower input capacitance will offer higher input impedance at higher frequencies.
-
product
High-Sensitivity, DC Stable ESVM
Model 323
The Trek Model 323 Electrostatic Voltmeter performs high voltage resolution, noncontacting, DC stable surface voltage measurements using a technique which maintains high measurement accuracy over a wide range of sensor probe to measured surface spacings.
-
product
Logic Probes
Logic probes allow you to capture signals using the logic portion of a mixed signal instrument. Yokogawa offers low and high voltage, isolated and non-isolated logic probes.