Showing results: 1 - 15 of 18 items found.
-
TCB-108 -
Criterion Instruments Limited
Model TCB-108 - Capacitance Bridge is a general purpose bridge for measurement of capacitors, capacitance of transformers and dielectric material. It comprises a transformer-type bridge operating from an internal 108 Hz generator(for accurate measurement at 60Hz) with digital readout of capactiance from 1 pF to 99.999 pF over four ranges and digital readout of D (dissipation factor) in percentage from 0-50%.
-
1620 -
IET Labs
The GenRad 1620-A Capacitance Measuring System is a self-contained assembly of the GR 1615-A Capacitance Bridge with appropriate oscillator and null detector for measurements at 11 frequencies between 20 Hz and 20 kHz. For applications requiring other or higher frequencies, to 100 kHz, the 1615-A bridge can be supplied separately and the oscillator and detector selected to meet your needs.
-
Guildline Instruments Ltd
Capacitance Bridge is an instrument employing the AC Current Comparator principle. The 9910A is a versatile instrument for a wide range of applications including capacitance measurements, cable testing, corona loss measurements, insulator and dielectric testing, inductance measurements, potential transformer error measurements, shunt reactor loss measurements and power transformer testing.
-
1621 -
IET Labs
The GenRad1621 Capacitance Measurement system is a completely self-contained system capable of capacitance measurements in increments as small as 0.1 aF (10-4 pF) and conductance measurements in increments as small as 100 aU (10-7 U; equivalent to a shunt resistance of 1010 M). Measurements are three terminal, with 2- or 3-terminal connection, and provision is also made for the connection of an external standard for comparison measurements.
-
SG2008 -
Shanghai Jiuzhi Electric Co., Ltd.
SG2008 Automatic 12kV Capacitance & Dissipation Factor Test Set is designed to measure dissipation (tgδ) and capacitance (C) in heavy electromagnetic interference environment such as in power plants or substations. Also it can be used in laboratory for high accurate test such asHigh Voltage (EHV) class Bushings, Windings of transformer (1/2/3 windings), shunt reactors, Current Transformer, Capacitor Voltage transformer(CVT), grading capacitors of Circuit Breakers, Surge Arrester and other electrical equipments. The test set is all-in-one structure: including precision digital bridge, 12kV/200mA frequency conversion power unit, reference capacitor (CN), and other electronic circuits. An external power supply can expand the test range. True portability is realized by the lightweight. Simple usage is realized by the full automation. High performance is realized by the digital process.
-
-
-
Eltel Industries
*Automatic Microprocessor controlled Guarded Bridge Circuit.*Suitable for testing at voltages up to 500kV.*Can be used to measure both Grounded and Un-Grounded Specimens.*Automatic guard circuit for three-terminal measurement.*Interface measurement and automatic interference suppression circuitry.*Optional range Extension Transformer for large capacitance values.*Test data storage facility.*RS-232 computer interface and USB printer interface.*Window Interface Software for data transfer.
-
AH 2500A -
Andeen-Hagerling, Inc.
The AH 2550A offers unparalleled stability, resolution and accuracy in a capacitance/loss bridge (whether manual or automatic). Its numerous state of the art features make it an exceptionally user-friendly instrument, just as was its predecessor, the AH2500A. The precision and ease of use of the AH2550A are creating new applications in science, calibration, and production in a wide range of fields.
-
AH 2700A -
Andeen-Hagerling, Inc.
The AH 2700A offers unparalleled stability, resolution, linearity and accuracy in a multi-frequency capacitance/loss1 bridge (whether manual or automatic). Its numerous state-of-the-art features make it an exceptionally user-friendly instrument. The precision of the AH 2700A is creating new applications in calibration, science, and production in a wide range of fields
-
YL Series -
Shanghai Jiuzhi Electric Co., Ltd.
The SF6 gas insulated standard capacitor is used together with a C and tan delta measuring bridge as the comparison standard leg of the bridge. It is used as Capacitance standard in measuring bridge Circuits to measure the dielectric dissipation Factor tand, Further-more, It can be used as high-voltage capacitor for voltage divider circuits of high-voltage transformer test.
-
Vettiner
High accuracy Schering bridge for the measurement of capacitance and dielectric dissipation factor (tan d) for the characterization of dielectric insulators, calibration of standards and manufacturing test of all industrial equipment.
-
Measurements International Ltd.
The Shunt Reactor Loss Measurement System is a microprocessor controlled, metrology based, high voltage Capacitance, Inductance and Reactor Loss Measurement bridge which is based on the two stage- compensated current transformer. The 7010C bridge can be ordered by itself or it can be ordered with high voltage capacitors up to 800 kV line to ground and two-stage-compensated current transformers up to 4000A. the system is fully automatic displaying the rms voltage at the top of the capacitor, the reactor current and the reactor losses.
-
Applied Relay Testing Ltd.
A connector test system which provides expansion of up to 160 Kelvin pair connections. The system incorporates high voltage AC and DC power supplies with a maximum output of +/- 2100 Volts peak for Hi Pot, Insulation resistance measurement. LCR bridge control is provided with 4 terminal multiplexing in order to add precision capacitance, inductance and resistance measurement capability. An integral H.V. capacitor bias option permits capacitance measurement to be made at up to 2.1kV.
-
1408 Series -
IET Labs
Ultra-high stability. The continuously improvingaccuracy of capacitor calibrations by NISTbrings a better knowledge of capacitance tostandards laboratories - provided, of course,the laboratories have adequate referencestandards. The 1408 Reference Standard Capacitors,with their high stability, are suitablefor calibration in parts in 107. The 1616 PrecisionCapacitance Bridge is highly recommendedfor accurate calibration of a wide range ofworking standards from such a reference.