PH-100/120 -
Pansco, Ltd
The Lantracker is a network tester, pin-by-pin cable tester, and tone generator all in one. As a network tester, it detects whether a network is active or inactive and displays network speed (10/100/1000 Mbps) in either case. It also flashes the network hub or NIC’s port light corresponding to the cable it is connected to, to show the cable’s port number. As a cable tester, it performs loop-back or remote tests of network, data, voice, and coaxial cables, displaying the results on a pin-by-pin LED display which moves from pin to pin automatically or manually. The Lantracker can be used to test cable or shield integrity, testing network function and speed, and tracing cable using its tone generator function (tone probe not included). Includes an adaptor for testing coaxial-F cable. Uses 1 9V battery.
-
Alliance Calibration
ACCELEROMETER AIR DATA MULTIMETER AMP METERBALOMETER BAROMETER CAPACITANCE METER CLAMP METER DLRO METER DIGITAL THERMOMETER DUROMETER FLOW METER HUMIDITY METER HYDRONIC MANOMETER MANOMETER THERMOMETER MULTIMETER pH METER TACHOMETER ANEMOMETER
-
MSR160 -
MSR Electronics GmbH
Four integrated analogue inputs, a high measurement rate of up to 1000/s per channel and its gigantic memory capacity, all packed into a small format are the key characteristics of the MSR160 data logger. The analogue inputs of the robust mini logger can be used for conventional sensors with analogue outputs (e.g. CO2, conductivity, pH etc). In addition, a multiple output switching power supply is also provided.
-
Sper Scientific
ORP (Oxidation Reduction Potential) measures a system’s relative state for gaining or losing electrons. ORP values are affected by all oxidizing and reducing agents, not just acids and bases that influence pH measurement. In practice, ORP measures the ability of a lake or river to break down waste products, like contaminants and organic matter. When the ORP value is high, there is lots of oxygen present in the water.
-
THB SERIES -
Transducer Techniques, Inc
Our THB Series through hole donut load cells offer anoutside diameter of 1.50 inches and up to four different thru-hole diameter options per capacity range. These load cells are manufactured from heat treated 17-4 ph stainless steel. The sensing element incorporates bonded foil strain gages of the highest quality and are sealed for protection against most industrial environments.
-
Digital Dialysate Meter™ D4 & D6 -
Myron L Company
The DIGITAL DIALYSATE METER is specifically designed to test both acetate and bicarbonate dialysate quality. Measure Conductivity, pH and Temperature to ensure proper mixing during dialysate preparation and as a final check of dialysate quality before hemodialysis treatment. There are no strips or reagents that expire or subjective interpretation of results. Internal sensors require the user to place the sample in the instrument, preventing contamination of dialysate by the measurement device.
-
2721 -
Georg Fischer Signet
Pre-amplification is required to protect the output signal of pH and ORP electrodes from a wide variety of electromagnetic interferences common in industrial environments. Signet 2721 is used if remote pre-amplification is required (e.g. tank temperature >80oC) or connecting another manufacturer's electrode to the Signet 5700 or 8750 instrument. The Signet 2721 should be used with special order sensors built with cables (Signet models 277X-HT or 277X-1-HT).
-
THD SERIES -
Transducer Techniques, Inc
Our THD Series through hole donut load cells offer an outside diameter of 3.00 inches and up to nine different through hole diameter options per capacity range. These load cells are manufactured from heat treated 17-4 ph stainless steel. The sensing element incorporates bonded foil strain gages of the highest quality and are sealed for protection against most industrial Environments.
-
THA SERIES -
Transducer Techniques, Inc
Our THA Series through hole donut load cells offer an outside diameter of 1.00 inches and up to two different through hole diameter options per capacity range. These load cells are manufactured from heat treated 17-4 ph stainless steel. The sensing element incorporates bonded foil strain gages of the highest quality and are sealed for protection against most industrial environments.
-
THC SERIES -
Transducer Techniques, Inc
Our THC Series through hole donut load cells offer an outside diameter of 2.00 inches and up to six different through hole diameter options per capacity range. These load cells are manufactured from heat treated 17-4 ph stainless steel. The sensing element incorporates bonded foil strain gages of the highest quality and are sealed for protection against most industrial environments.
-
Ultrameter™ III 9PTKB -
Myron L Company
The Ultrameter III 9P™ AHL Titration Kit, is based on the tried and tested design of the Ultrameter II™. The 9P adds the ability to perform in-cell alkalinity and hardness titrations either as stand-alone measurements or as part of an LSI calculation. Alkalinity, hardness, pH and temperature values can be manipulated in the LSI calculator to predict the effect of changes on water balance. Measurements are extremely accurate. And the 9P is simple to operate and maintain.
-
UltrapenX2™ PTBT4 -
Myron L Company
*Accuracy of up to ±0.3 ppm FCE*Calibration with pH and ORP Standard Solutions*Automatic Temperature Compensation*Measurement Storage with Time, Date and Location*Export Stored Measurement Data Via Email*Live or Hold Mode – User Selectable*Proprietary Sensor Design*Rugged Design with Aircraft Aluminum Body*Durable, Epoxy Encapsulated Electronics*Waterproof*Powered by One N Type Battery (Included)
-
18534PS1 -
Carl E. Holmes Company
Input power is 380 VAC, 3 PH, 50 Hz, P/N 18534PS1Output is 0 to 250 VDC, 200 Amp max.Variable Transformer is used to vary the output. SCR controller is not used, as it generates harmonics.Input control is 0 to 3.6 VDCIndoor enclosure, 50"H x 46"W x 36"DOutput voltage and current feedback as 4/20 mA for PLC interface.All input/output connections are inside the enclosure
-
LAQUA PC220 -
HORIBA, Ltd.
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
Extech EC500 -
Extech Instruments Corporation
The EC500 is Conductivity/TDS/Temperature Meter. Measures 5 parameters including Conductivity, TDS, Salinity, pH, and Temperature using one electrode. Analog bargraph indicates trends. Memory stores up to 25 labeled readings. Waterproof meter with high-accuracy multi-ranging sensor. Features Auto Power off with disable. Complete with meter and electrode, protective cap, sample cup, four 3V CR-2032 batteries, and 48" (1.2m) neckstrap.