-
product
Fixed Laser Source Module
Keysight offers a broad choice of fixed laser sources, which are available as single-wavelength and dual-wavelength modules as part of the Keysight Lightwave Solution Platform. The Keysight 8165xA Fabry-Perot laser sources can be used in conjunction with optical power meter modules for insertion loss, optical return loss and PDL measurement of broadband components and fiber. The Keysight 81663A Distributed Feedback Laser Sources are best suited for amplifier test and WDM system test applications. Keysight covers PON and common WDM wavelengths with its 81663A Distributed Feedback (DFB) laser source modules. The precise tunability around ITU-grid center wavelength gives you the flexibility to match test setups to the latest requirements of the DWDM-system. The fine-tuning allows to shift the center wavelength from one DWDM transmission channel to the adjacent channel in dense WDM systems. The built-in isolator ensures highest laser stability, even when reflections are present in the optical path.
-
product
Fixed Wavelength CW Laser Source (DFB)
Laser 1200 Series
The Laser 1200 Series is a highly customizable fixed-wavelength Continuous Wave (CW) laser source available in a wide range of wavelengths and powers.With seamless PXI integration, it can be easily integrated into new or existing PXI test setups. Save space, lower your costs and improve testing efficiency while delivering reliable and repeatable results in production or research environments.
-
product
NI-9207, 500 S/s, 16-Channel C Series Voltage and Current Input Module
781068-01
500 S/s, 16-Channel C Series Voltage and Current Input Module - The NI‑9207 is a combination voltage and current input module designed with industrial systems in mind. It features eight current and eight voltage input channels, with built-in noise rejection.
-
product
AC / DC Current Probe, 100 KHz, 100 A
1146B
The Keysight 1146B AC / DC probe provides accurate display and measurement of currents up to 100 A DC or peak AC / DC to 100 kHz without breaking the circuit. The 1146B AC / DC probe has hall-effect sensor technology to measure AC and DC signals. It is compatible with any Keysight oscilloscope with 0.2 to 0.5 V / div sensitivity and 1 MΩ BNC input.
-
product
Brute High Current Probe
P4301-2F
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
product
Alternate 24.00 (680.00) - 96.00 (2722.00) Godzilla High Current Probe
HC375F-6
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
product
High-Voltage Differential Probe, 70 MHz
N2891A
Use the N2891A 70-MHz high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2891A differential probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to ±7000 V of differential and common mode voltage.
-
product
NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module
780968-02
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
product
Brute High Current Probe
P4301-1Z
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
product
DC Coupled Current Probe
34134A
Measure a wide range of applications with this battery-powered, clamp-on probe; use with DMMs or voltmeters
-
product
PXIe Short SMU
52403P
Chroma's 52403P is a PXI Express Short Pulse SMU (Source/Measure Unit) designed for fast, precise and reliable sourcing and measurement of thermo-sensitive devices such as high-power laser diodes (LD). Integrating a high-speed pulser, a high precision SMU and a DAQ module into a single PXIe SMU, the 52403P can measure both the LIV and the low-level leakage current of a high-power LDs.
-
product
HPC High Current Probe
HCP-13
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Tunable Laser Source, High Power And Lowest SSE, Top Line
N7776C
The new Keysight N7776C top line tunable laser source is designed to reach best-in-class accuracy in static and swept operation for outstanding test efficiency. Two-way sweeps up to 200 nm/s speed with sub-picometer repeatability and without impacting the specified dynamic accuracy accelerate wavelength-dependent alignment processes and the automated calibration of wavelength-selective devices. Shorter time to testing and faster swept-wavelength tests help reduce test cost per device, improve test margins and lower the cost of ownership.
-
product
PXIe-4139 , ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit
782856-03
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
product
NI-9203, 200 kS/s, ±20 mA, 8-Channel C Series Current Input Module
779516-01
200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.
-
product
Tunable Laser Source - PXI
Laser 1000 Series
The Laser 1000 Series PXIe module is a Continuous Wave (CW), tunable laser source offering high-power output, narrow 100kHz linewidth and 0.01pm resolution tunability.With seamless PXI integration, it can be easily integrated into new or existing PXI test setups. Save space, lower your costs and improve testing efficiency while delivering reliable and repeatable results in production or research environments.
-
product
High-Voltage Differential Probe, 100 MHz
N2790A
Use the N2790A 100-MHz high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2790A probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to 1,400 V of differential voltage and 1,000 V of common mode voltage.
-
product
High Precision Source Measure Unit (SMU) - Hybrid Compatible PXI, 100ks/S Programming/Measurement Speed
52400 series
Hybrid Compatible PXIFour quadrant operationHigh source/measurement resolution (multiple ranges)Low output noiseHigh programming/measurement speed (100k s/S) & slew rateOptional measurement logDIO bitsOutput profiling by hardware sequencerProgrammable output resistanceFloating & Guarding output16 Control Bandwidth SelectionMaster / Slave operationDriver with LabView/LabWindows & C/C# APISoftpanel GUI
-
product
PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit
783761-01
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
product
Fixed Wavelength CW Laser Source (FP) - MATRIQ
The Laser-1102 is a Continuous Wave (CW) laser source offering high power 850 nm output into multimode fiber with stable output power operation.
-
product
PXIe-4135, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit
783762-01
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit - The PXIe-4135 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology and native triaxial connectors help you perform high-precision measurements with a current resolution of 10 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4135 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
product
NI-9207, 500 S/s, 16-Channel C Series Voltage and Current Input Module
781068-02
500 S/s, 16-Channel C Series Voltage and Current Input Module - The NI‑9207 is a combination voltage and current input module designed with industrial systems in mind. It features eight current and eight voltage input channels, with built-in noise rejection.
-
product
CC0550X, 50 MHz, 5 Arms Current Oscilloscope Probe
786846-01
The CC0550X, or Hioki CT6700, is a clamp-on current probe that offers a wide DC to 50 MHz bandwidth and 5 Arms of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor … controllers. The probe requires an external power supply.
-
product
Source Measurement Unit
SMU32
The SMU32 is a low cost solution for V/I source and measurement. The SMU32 offers PMU/DPS in a compact, 3U PXI form factor. The SMU32 supports -1V to +10V +- 32 mA FVMI/FIMV modes. 8~32 PMUs can be ganged to DPS for high current driving.
-
product
PXIe Precision Source/Measure Unit, 15 MSa/s, 100 FA, 60 V, 3.5 A DC/10.5 A Pulse
M9603A
The Keysight M9603A is a PXIe precision SMU featuring best-in-their-class narrow pulse width as narrow as 10 μs. It enables dynamic/pulsed measurements with up to 15 MSa/s for broad emerging applications such as VCSEL optical devices.
-
product
Standard- 27.20 (771.00) - 64.00 (1814.00) Godzilla High Current Probe
HC375F-4
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
product
CC5002X, 2 MHz, 500 A Current Oscilloscope Probe
786848-01
The CC5002X, or Hioki 3275, is a clamp-on current probe that offers a wide DC to 2 MHz bandwidth and 500 A of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
product
NI-9266, 8-Channel C Series Current Output Module
785047-02
8-Channel C Series Current Output Module - The NI‑9266 is ideal for interfacing and controlling industrial current-driven actuators. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9266 includes channel‑to‑earth ground isolation for safety and noise immunity.
-
product
CP400X, 400 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784254-01
The CP400X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 2 meters in length. The CP400X attaches to BNC connections on both the signal input and instrument sides.
-
product
High-Voltage Differential Probe, 200 MHz
N2805A
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.





























