-
product
15 Pin D-Type Connector to Connector
The 15-Pin D-Type cable assembly is constructed from 19/0.18 (21AWG) Tinned Copper Wire with PFA insulation. Male screwlocks are provided to secure the connectors to their associated products.
-
product
Cable Locator
A cable locator can locate open power cables, either live or without current, with voltages up to 300 V. A cable locator can locate cables, circuits, short circuits and ground wires. To perform these functions, it is not always necessary to disconnect electrically sensitive devices or to disconnect the power to the cable being tested. Many cable locator devices also can locate ferrous and non-ferrous metals, wood and plastic with high degrees of accuracy.
-
product
Soil Moisture Sensor
Modbus RS485
This is a contact-less capacitive soil moisture sensor, a continuation of my I2C soil moisture sensor. This particular version of the sensor is suited for more professional installations where long cable runs is a requirement. It adds a local voltage regulator to mitigate the voltage drop and RS485 transceiver to accommodate long wires, also reverse polarity and an additional ESD protection level is added.
-
product
High density, ESA approved PCB connector
KMC Series
Smiths Interconnect's KMC series is an ESA qualified, high density board to board and board to wire interconnect available in multiple configurations from 26 to 162 positions
-
product
Steady State Chamber
Burnsco Environmental Test Chambers
Swivel castors with brakesWelded series 304 stainless steel interior and exterior.Interior light and viewing windowNon-settling, high temperature, fiberglass insulation.Fast response, nichrome wire heating elements.
-
product
Split type AC Current Sensor
CTF-5A
MULTI MEASURING INSTRUMENTS Co., Ltd.
* Suitable for current measurements of terminal feeder. * Wire stopper is equipped for the slipping protection. * The special connector is not necessary as the output terminals are provided. * Open circuit protection and nonflammable plastic material.
-
product
E-Z Check® Circuit Tester
61-035
*Tests for correct wiring, open ground, reverse polarity, open hot, open neutral, hot on neutral, hot and ground reversed with open hot in 3 wire, 120 VAC circuits*Simulates ground fault for testing GFCIs*No-slip ergonomic design maximizes comfort*Premium neon lamps prevent false readings*Tough, impact-resistant case*2-year warranty
-
product
20-Pin GMCT Cable, Female to Unterminated, Cut Ends, 16A, 0.5m
A020GFR-C-1B050
The 16A 20-Pin GMCT cable assembly is constructed from 19/0.41 (14AWG) Copper Wire with PFA 500V insulation. Screwlocks are provided to secure the connector to associated product. The unterminated connections are coded to match the connector pin designation and include crimped on ferrules to ensure the wire strands cannot break when they are terminated.
-
product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Dual Channel
40-204-002
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
product
20-Pin GMCT Cable, Male to Unterminated, Cut Ends, 10A, 1m
A020GMR-C-0C100
The 20-Pin GMCT cable assembly is constructed from 19/0.254 (18AWG) Tinned Copper Wire with PFA insulation. Screwlocks are provided to secure the connector to associated product. The unterminated connections are coded to match the connector pin designation. Users may need to make their own cable strain relief arrangements when using this product and should ensure appropriate electrical safety precautions are observed.
-
product
Cable Assembly 44-Pin D-Type Female to Female, 2m
40-970-044-2m-FF
The 44-Pin D-Type Density and a Half cable assembly is constructed from 26 AWG Silver Plated Copper Wire with PFA insulation. Screwlocks are provided to secure the connectors to their associated products.
-
product
Cable Assembly 68-Pin Micro-D Male to Unterminated
A068SMR-C-6A050
The 68-Pin Connector to Unterminated Cable Assy is constructed from 7/36 (28AWG) twisted pair wires with polypropylene insulation. The wires are colour coded to match the connector pin designation. The connector can be secured to the product by 2-56 UNC Screwlocks.
-
product
Cable Assembly, 25-Pin D-Type, Male to Unterminated With Cut Ends, 0.5m
A025DM5-C-0A050
The 25-Pin Connector to Unterminated Cable Assy is constructed from PFA insulated 19/0.18 (21AWG) Tinned Copper wire. The connector can be secured to the product by screwlocks. The unterminated connections are coded to match the connector pin designation. Please ensure appropriate electrical safety precautions are observed when using this product.
-
product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
785186-01
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
Gauge Type T Thermocouple Wire
W-TW-40P2
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
product
Cable Assembly, 25-Pin D-Type, Male to Unterminated With Tinned Ends, 2m
A025DM5-T-0A200
The 25-Pin Connector to Unterminated Cable Assy is constructed from PFA insulated 19/0.18 (21AWG) Tinned Copper wire. The connector can be secured to the product by screwlocks. The unterminated connections are coded to match the connector pin designation. Please ensure appropriate electrical safety precautions are observed when using this product.
-
product
37-Pin D-Type Breakout DIN Male
40-967-037-M
This termination option is capable of accepting heavy duty connection wires and uses rising clamp screw terminals to minimize the danger of copper strand damage. Users should care take to protect the termination, provide a suitable method of restraining the cables, and ensure appropriate electrical safety precautions are observed.
-
product
Load Cell Amplifier Signal Conditioner with Removeable Terminals
MODEL LCA-RTC
The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.T...show more -
product
Cable Assembly 15-Pin D-Type, Female to Unterminated With Cut Ends, 0.5m
A015DF4-C-0A050
The 15-Pin Connector to Unterminated Cable Assy is constructed from PFA insulated 19/0.18 (21AWG) Tinned Copper Wire. The connector can be secured to the associated product by screwlocks. The unterminated connections are coded to match the connector pin designation. When using this product additional cable strain relief arrangements may be necessary and appropriate electrical safety precautions should be observed.
-
product
4-Pin Power D-Type Female to Unterminated With Cut Ends
40-972-404-2m-FU
The 4-Pin Power D-Type Connector to Unterminated Cable Assy is constructed from PVC insulated 56/0.3 (12AWG) Copper wire. The connector can be secured to the product by screwlocks and the unterminated connections are coded to match the connector pin designation.
-
product
MP CI set
The MP CI set up to measure coupling impedance is used to determine EMC characteristics of connectors and cables. The coupling inductivity defines the coupling inductance of external disturbance on the shield or on the ground with the desired signals. If the coupling inductivity is considered in the construction set-up and the pin or wire assignment of connectors or cables, then the connectors or cables will be more interference-resistant. The MP CI set-up for measuring coupling impedance can be...show more -
product
Bending Test Machines
Infinity Machine International Inc.
Bending Test Machines by Infinity Machine International Inc. - for applications such as bending cycle test machine wire wing left and right tester, 90° 180° bending wire swing test left and right optical cable repeated bend testing machine, cable bending durability tester, cable flex bending test machine, high precision bending test machines, and more.
-
product
Cable Assembly, 78-Pin D-Type, Female to Unterminated With Ferrules
40-972-078-0.5m-FU
A 78-Pin D-Type to Unterminated cable assembly constructed from 7/0.15 (26AWG) Silver Plated Copper Wire. Screwlocks are provided to secure the cable connector to associated products. Has a 45 degree cable exit away from pin 1.
-
product
Mobile Comm DC Source w/ Battery Emulation
66321B
The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacture...show more -
product
3-Pin Power D-Type Cable, Male to Female, 2m
40-970-403-2m-MF
The 3-Pin Power D-Type cable assembly is constructed from 50/0.26mm2 (14 AWG) Tinned Copper Wire with PVC insulation. Screwlocks are provided to secure the connectors to their associated products.
-
product
Cable Assembly 68-Pin Micro-D Male to Unterminated, Ferrules, 0.5m, Screwlocks
A068SMR-F-6B050
The 68-Pin Connector to Unterminated Cable Assy is constructed from 7/36 (28AWG) twisted pair wires with polypropylene insulation. The wires are colour coded to match the connector pin designation. The connector can be secured to the product by 2-56 UNC Screwlocks.
-
product
SPL-03C-153 Step Probe
SPL-03C-153
Current Rating (Amps): 6Average DC Resistance lower than (mOhm): 50Test Center (mil): 125Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 127Recommended Travel (mm): 3.23Overall Length (mil): 1,530Overall Length (mm): 38.86Rec. Mounting Hole Size (mil): 95Rec. Mounting Hole Size (mm): 2.40Rec. Mounting Hole Remark: 94 to 96 mil / 2.39 to 2.44 mmRecommended Wire Gauge: 22-26 AWGRecommended Drill Size: #41 or 2.40 mm
-
product
3-Pin Power D-Type Cable, Female to Unterminated, Ferrules, 0.5m
A003PF4-F-5A050
The 3-Pin Power D-Type cable assembly is constructed from 50/0.26mm2 (14 AWG) Tinned Copper Wire with PVC insulation. Screwlocks are provided to secure the connectors to their associated products.
-
product
230V AC Socket Tester(For UK)
1942
Peaceful Thriving Enterprise Co Ltd
*With UKCA Approval.*Test for 230VAC circuits.*Neon indicators.*Detect faulty wiring status in 3 wire receptacle.*Various combinations of 3 neon indicators tell if wiring is OK or 6 possible faulty conditions.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 1W*Frequency: 50Hz