Showing results: 136 - 150 of 4319 items found.
-
65-233-903 -
Pickering Interfaces Ltd.
The 65-233-903 plug-in module is part of a scalable high voltage switch platform that provides a high voltage switching solution with capability up to 9 kV.
-
65-233-902 -
Pickering Interfaces Ltd.
The 65-233-902 plug-in module is part of a scalable high voltage switch platform that provides a high voltage switching solution with capability up to 9 kV.
-
65-233-904 -
Pickering Interfaces Ltd.
The 65-233-904 plug-in module is part of a scalable high voltage switch platform that provides a high voltage switching solution with capability up to 9 kV.
-
65-233-901 -
Pickering Interfaces Ltd.
The 65-233-901 plug-in module is part of a scalable high voltage switch platform that provides a high voltage switching solution with capability up to 9 kV.
-
40-531-021 -
Pickering Interfaces Ltd.
Model 40-531 very high density matrix modules are configured as a 32x8, while the 40-532 modules are configured as a Dual 16x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.
-
40-532-021 -
Pickering Interfaces Ltd.
This high-density reed relay matrix with 256 crosspoints. This model is configured as a Dual 16x8, model 40-531 is configured as a 32x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version can be used for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.
-
Carl E. Holmes Company
- Active Switching Rectifier, 2 KW, P/N 6016C- Input Range: 9 VAC to 35 VAC, 3 PH- Frequency Range: DC to 10 kHz- DC output: 13.5 VDC, 70 Amps without any heatsink (Test #1)- DC output: 13.5 VDC, 150 Amps with heatsink (Test #2)- Dimensions: 8″W x 8″L x 3″H or similar- AC to DC and DC to DC applications- Generates less heat as power MOSFET Switching is used- The output voltage is the same as the input voltage
-
HF-960EM -
HORIBA, Ltd.
Measures a wide range of HF concentration from low concentration to undiluted liquid. The HF-960EM achieves high precision measurement by the auto-correction range switching function. Also has the capibility of cleanliness with all PFA sensors. Measurement range: 0 - 50%.
-
40-532-022 -
Pickering Interfaces Ltd.
This high-density reed relay matrix with 256 crosspoints. This model is configured as a Dual 16x8, model 40-531 is configured as a 32x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version can be used for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, seven PXI modules will form a 224x8 Matrix, a total of 1792 crosspoints in a 7-slot PXI Chassis.
-
40-531-022 -
Pickering Interfaces Ltd.
Model 40-531 very high density matrix modules are configured as a 32x8, while the 40-532 modules are configured as a Dual 16x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, seven PXI modules will form a 224x8 Matrix, a total of 1792 crosspoints in a 7-slot PXI Chassis.
-
Pickering Interfaces Ltd.
This LXI High Voltage Switch range consists of our LXI Scalable Chassis (model 65-200-002) that can be easily reconfigured by the removal and insertion of our 9 kV switching plug-in modules detailed below. The unit is purchased as an empty chassis along with the number of plug-in modules initially required (up to six SPDT switch modules or up to six multiplexer modules).
-
40-511-022 -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switchingconfigurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signalrouting in ATE and data acquisition systems.Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Larger matrices may be constructedby Daisy Chaining the common signals from multiple PXI modules.
-
Part No. 682 -
Teledyne Defense Electronics Relays & Coax Switch
The 682 is a state-of-the-art solid-state relay designed for use in AC power switching applications. Back-to-back SCRs are configured for zero-voltage turn-on and can handle current surges up to 8A. The patented circuit design assures the lowest possible EMI by virtually eliminating commutation spikes while maintaining excellent noise immunity.MSL 1 Available options include:682-1 2A, 250Vrms Load; 3.8-32Vdc Control
-
VDM Series -
Cytec Corp.
Cytec's VDM Series of video and RF switching systems are based on a solid state switch fabric and are available in non-blocking, full fan-out configurations of 8x8 to 32x32, with a small signal bandpass of 400MHz. Input and output buffers can be modified for different impedance or signal levels. Both the switch modules and control modules are modular for ease of expansion and low MTTR. Start with an 8x8 matrix and expand to a 32x32 simply by adding additional input and output modules.
-
40-521-021 -
Pickering Interfaces Ltd.
An ultra high density matrix module is configured as a 24x8, this range is availablein a choice of reed relay formats: 1-pole (shown here), 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisitionsystems. These PXI matrix cards are constructed using high reliability RutheniumElectro-Plated Reed Relays, offering >10e8 operations to give maximum switchingconfidence with long life and stable contact resistance.