Filter Results By:

Products

Applications

Manufacturers

Surge

A spike in voltage.

See Also: Transient


Showing results: 241 - 255 of 291 items found.

  • Single 24-Channel 1-Pole 5 Amp PXI Solid State Multiplexer

    40-652-101 - Pickering Interfaces Ltd.

    The 40-652 range of multiplexers uses solid state relays with high tolerance to surge currents and hot switching events. Each multiplexer provides an isolation relay in the common to minimize capacitive loading when expanding the multiplexer across multiple modules. The 40-652 can sustain 30A for 300s on hot or cold switching. User connections are made via a 50-way D-Type connector which is fully support by our comprehensive range of cables and connector accessories.

  • Single 48-Channel 1-Pole 5 Amp PXI Solid State Multiplexer

    40-652-001 - Pickering Interfaces Ltd.

    The 40-652 range of multiplexers uses solid state relays with high tolerance to surge currents and hot switching events. Each multiplexer provides an isolation relay in the common to minimize capacitive loading when expanding the multiplexer across multiple modules. The 40-652 can sustain 30A for 300s on hot or cold switching. User connections are made via a 50-way D-Type connector which is fully support by our comprehensive range of cables and connector accessories.

  • Single 24-Channel 2-Pole 5 Amp PXI Solid State Multiplexer

    40-652-003 - Pickering Interfaces Ltd.

    The 40-652 range of multiplexers uses solid state relays with high tolerance to surge currents and hot switching events. Each multiplexer provides an isolation relay in the common to minimize capacitive loading when expanding the multiplexer across multiple modules. The 40-652 can sustain 30A for 300s on hot or cold switching. User connections are made via a 50-way D-Type connector which is fully support by our comprehensive range of cables and connector accessories.

  • Standard Serial Page EEPROM

    STMicroelectronics

    Serial Page EEPROM is a high-density, page-erasable SPI EEPROM memory that combines flexibility, performance, and ultra-low power. The Serial Page EEPROM with proprietary NVM cell technology delivers fast erase/write performance with high cycling endurance and robust retention. The new architecture allows fast wake up and byte flexibility, as well as block management and fast quad output, while keeping current surge and energy budget at very low levels.

  • Parasitic Drain Tester

    64970 - Lisle Corp.

    Replaceable in-line fuses protect both the meter and tester in the event a high current source on the vehicle is left on. The multimeter is bypassed with the switch during connection in case of a power surge. The tester and meter can remain connected until other computer systems shut down, isolating the drain. As a convenience, stacking banana connectors are used on the tester. This allows voltage to be measured on various locations on the vehicle during the drain test, using standard test leads.

  • Mobil Cable Test and Fault Location System

    SWG-12 (SWG-32) - Kharkovenergopribor Ltd.

    • testing cable insulation with DC (rectified) voltage up to 32 kV;• conditioning faults by burning faulty cable insulation with current up to 100 mA;• pre-locating cable faults with the reflectometer RIF-9 based on the pulse reflection method (TDR), voltage wave oscillation method (DECAY), impulse current envelope (ICE) method and arc reflection method (ARC / ARC multi-shot);• pinpointing cable faults with the acoustic method with up to 2000 J surge wave generator and a suitable signal receiver.

  • Universal Locator

    UL 30 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR UL 30. The UL 30 receiver is used together with a ground microphone (BM 30) and a surge voltage generator (SSG, STG) to pinpoint cable faults. With the coil integrated in the BM 30 for runtime measurement, the device determines the time difference between the magnetic and acoustic signal. This particularly offers special advantages when d ealing with faults difficult to locate acoustically.* Built-in speaker* Splashproof design* Large, illuminated display* Lightweight

  • Inrush Current Generators for Zno Production Line

    Shanghai Guantu Technology Co., Ltd.

    Inrush Current Generator Standard: IEC61008, IEC61009, I61051/61643, ANSI C62.31, C62.33, C62.35, TU K20, K21, K44, K45, UL943Inrush Current Generator Features1. LCD screen display, built-in computer control, man-machine dialogue, easy to operate.2. Program-controlled high-voltage power supply, high voltage stability and precision3. Imported non-inductive high-power resistors are used to ensure the consistency of surge waveforms4. The main switch adopts electronic switch discharge mode, and the output polarity is automatically switched

  • Test Sets For Diagnostic Testing

    NEO TELE-TRONIX PVT. LTD

    Test Sets For Diagnostic Testing are designed to test Oil Resistivity, Tan Delta, High Voltage Surge Comparison, etc. These test sets are automated instruments used to measure electrical features to insulate transformer oil, liquids and varied other insulating materials. They are ideal for revealing different localized problems and varied weak spots in the insulation. These modern testing sets are designed to provide high accuracy in results. In addition to this, they are easy to maintain testing sets available to ensure accurate readings.

  • Portable Electrical Management Systems

    EMS-PT30C - Progressive Industries

    Progressive Industries Portable Electrical Management Systems (EMS) offer quick and easy RV electrical protection. A true plug-and-play application with no installation required. You will feel secure with multi-mode surge, voltage, polarity, and lost/open neutral protection. Each unit includes a digital display, scrolling continuously through the power source information: voltage(s), current frequency, error code, and previous error code (if applicable). Additionally, the computer is driven by state of the art microprocessors.

  • Power Frequency Transducer

    PP1S - Hsiang Cheng Electric Corp

    1. Measuring and conversion IEC 6882. Dielectrical strength IEC 688 4 KVac / 1 min.3. Impulse test ANSI C37.90 / 1989 IEC 255-3 5KV ( 1.2 x 50 us ) 3KA ( 8 x 20 us ) - current coil4. Surge test (ring wave) ANSI C37.90 / 1989 ( 3KV - 0.5us / 100KHz ) IEC 255-3 ( 2.5KV - 0.25ms / 1MHz )5. Adaptability for power system VDE 0110 6. Measuring reliability VDE 3540

  • Mobile Cable Fault Location System

    Syscompact 2000 - BAUR Prüf- und Messtechnik GmbH

    Fault location with Syscompact 2000. The Syscompact 2000 is a multifunctional cable fault location system designed for modular 19" rack technology. The integrated surge and test generator is used for cable and sheath testing as well as for precise location of high-resistive and intermittent faults. The SYSCOMPACT 2000 is preferably used in low- and medium-voltage networks for fault location up to a cable lengths of 65 km. * Fast and reliable * Precise, dependable cable fault location High performance * high voltage unit* Integrated proven cable fault pre-location methods

  • Time Domain Reflectometer

    IRG 2000 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR IRG 2000. The IRG 2000 impulse reflection measurement unit or time domain reflectometer is a handy, easy to carry device for single-phase cable fault pre-location. It is used in combination with a surge voltage generator on low-, medium- and high-voltage cables 0 - 65 km in length. It can also be used on live cables carrying voltage up to 400 V.* Easy and quick cable fault location* Light, compact and manageable* Main unit for the tried-and-tested pre-location method* Ideal for integration in measurement systems

  • Power System Multimeter

    928A - Arbiter Systems, Inc.

    The Model 928A Power System Multimeter with Floating-Point DSP™ Digital Signal Analysis is an AC Power measurement instrument, providing outstanding performance and flexibility in a small, hand-held package. Not only does the Model 928A measure basic data and power quantities, but it also measures power quality including harmonics, flicker, sags, surges and interruptions. Incorporating a graphic LCD display, serial communications, real time clock and an unprecedented combination of features makes the Model 928A the ideal instrument for the power professional.

  • AC Motor Tester

    AIP892X series - Qingdao AIP Intelligent Instruments Co., Ltd

    This product is suitable for electrical performance testing of all types of motors, such as home appliance motors (washing machines, air conditioners, fans, etc.), pump motors, stepper motors, etc. One-stop testing completes all set items, stable, fast, efficient and accurate, widely used by domestic and foreign enterprises.This AC motor tester test items: AC Hi-pot, insulation resistance, surge, DC winding resistance, no-load characteristics, low voltage start, locked rotor, rotation, PG characteristics.