Filter Results By:

Products

Applications

Manufacturers

Sources

The origin.


Showing results: 2596 - 2610 of 2910 items found.

  • 3-Channel DC Current Datalogger

    Extech SD900 - Extech Instruments Corporation

    Extech's SD900 allows technicians to easily monitor and record DC mA values from 3 external sensors, transducers, and other sources using one meter. It also stores the time and date of when readings are taken. The logger features a large triple LCD display and records data on an SD card in an Excel®-ready format for easy transfer to a PC for analysis, trending, and archiving. Complete with six AAA batteries, SD memory card, Univeral AC Adaptor with multi-plugs (US, EU, UK, AUS), 3 input connect sockets, and mounting bracket.

  • Push Button Controller

    Stack-Match II - Array Solutions

    Stack Match controller is a replacement for the rotary switch Stack Match controller. It features pushbutton switches for easy antenna selection and has outputs for both phase control and an auxiliary output. It is a component of the ShackLAN product line and as such can be fully remotely controlled via computer with our ShackLAN Control Center software. All outputs are switched with relay contacts for maximum reliability and power for the external switching unit may be applied from a separate power source to provide maximum isolation from the ShackLAN network. There is also a PTT input to allow different stack configurations for transmit and receive.

  • HV Power & Transient Isolators

    B-1020-C - ROSS ENGINEERING CORPORATION

    These supply 120V or 240V AC continuous power for equipment that must operate while at a high voltage to ground or power source. For example, a fiber optic transmitter at the HV level for waveforms to be received and measured or recorded by grounded instrumentation might be powered by an isolation transformer secondary to primary either insulated by potting, oil or air. The low dielectric constant of air insulation provides lower capacitive coupling between the secondary and the primary or ground than would solid or oil insulation. The lower capacitance provides better isolation both at line frequency and especially at high frequency voltages such as lightning or switching transients.

  • Fiber Optic Transmission Systems

    B-1020-B - ROSS ENGINEERING CORPORATION

    Ross Engineering Corporation has developed a HV compact analog fiber optic transmitting and receiving system, with optional over-voltage limiting, designed to drive instrumentation from a DC to 1MHz signal source. The system is available with optional multiple input and output ranges of ±0-1V PK, 0-5V PK to 0-10V PK. It will also operate in conjunction with Ross Engineering Corporation’s high accuracy high voltage wideband voltage dividers, which are useful from DC to over 10MHz up to 1,000,000V PK at 0.01% to 3% accuracy. Transmitters and receivers can be powered by either AC or DC.

  • X-ray Fluorescence Sulfur/Chlorine-in-oil Analyzer

    MESA-7220V2 - HORIBA, Ltd.

    The MESA-7220V2 measures both sulfur and chlorine in petroleum based products using the Monochromatic Energy Dispersive X-ray Fluorescence (EDXRF) method. A monochromatic X-ray source is used in order to obtain an ultra-low noise background which affords the best detection limits for both sulfur and chlorine.The detector window size was increased to collect more fluorescent X-rays and thus achieve lower level ppm values. This provides excellent, repeatable performance at both low and high concentrations of both elements.By adjusting the angle of the graphite crystal, the excitation beam can be measured to excite sulfur in the sample, increasing sensitivity.

  • Scanning XPS Microprobe

    PHI Quantera II - Physical Electronics

    The core technology of the PHI Quantera II is PHI’s patented, monochromatic, micro-focused, scanning x-ray source which provides excellent large area and superior micro-area spectroscopy performance. Spectroscopy, depth profiling, and imaging can all be performed over the full range of x-ray beam sizes including the minimum x-ray beam size of less than 7.5 µm. In addition to superior XPS performance characteristics the PHI Quantera II provides two in situ sample parking stations which enables the automated analysis of all three sample platens in a single user defined analysis queue.

  • Beltronics International Units

    RX65i Red - Beltronics

    The Beltronics RX65i is the most up-to-date International detector for the discriminating driver. The RX65i features segmented Ka band for the ultimate in narrow-band detection, selectable band preferences (ON/OFF), expanded K band sweep, K Pulse detection, and Hyper K detection for low-power K band pulsed sources. AutoScan and RDR (Radar Detector Rejection) make the RX65i the quietest performance detector, immune from annoying false alerts. Includes Laser detection, Safety Warning System, Red LED display, Nylon travel case, and Beltronics exclusive SmartPlug heavy-duty coiled cord.

  • Beltronics International Units

    RX65i Blue - Beltronics

    The Beltronics RX65i is the most up-to-date International detector for the discriminating driver. The RX65i features segmented Ka band for the ultimate in narrow-band detection, selectable band preferences (ON/OFF), expanded K band sweep, K Pulse detection, and Hyper K detection for low-power K band pulsed sources. AutoScan and RDR (Radar Detector Rejection) make the RX65i the quietest performance detector, immune from annoying false alerts. Includes Laser detection, Safety Warning System, Red LED display, Nylon travel case, and Beltronics exclusive SmartPlug heavy-duty coiled cord.

  • V-FullWaver

    IRIS Instruments

    The V-FullWaver systems were specifically developed for precise full waveform time domain Induced Polarisation, Resistivity and SP measurements. Each system is fully independent; incorporating its own power source, GPS module and digital memory for up to 3 months continuous recording. The V-FullWaver is a dual channel Induced Polarisation, Resistivity and SP receiver. Continually recording at 10ms sample rate provides a full waveform record. It can be synchronized on the GPS PPS signal, allowing an easy process of the signal. Data on the memory can be downloaded directly on a simple USB stick from all the Fullwavers.

  • Vibrator Control System

    FORCE-III - Seismic Source Co.

    The Force 3 Vibrator Control System is the newest generation of vibrator control system. It is designed to control individual vibes, or synchronize entire fleets of trucks. Using GPS, or VHF/UHF radio, for its time base the Force 3 both starts the Vibrator and controls its sweep with unparalleled precision and accuracy.The Force 3 is equipped with the latest ADC chips for better sweep resolution, increased computing power for faster response, GPS for precise source location, 8 Gbytes of internal memory for integrated VSS and PSS data storage, and integrated Wi-Fi for easy data offloading.

  • Modular Tabletop Interconnect Box

    Cable Nooks - ALTINEX, Inc.

    Designed for boardrooms and conference rooms, the modular Cable-Nook provides a simple and effective way of hiding/storing multimedia cables and connectors. The cables remain connected to a presentation system enabling the user to access connections to video, audio, and other media sources. The modular Cable-Nook uses a half-moon lid that remains flush with the table when not in use. To access the cables or connectors, simply lift the door and pull the cable ends out, or plug computer video cables into any installed fixed connectors. The lid closes easily even with several cables in use. After the presentation, the cable ends are returned to the Cable-Nook for safe storage.

  • Spectrometer Systems

    FLAME-CHEM - Ocean Optics, Inc.

    FLAME-CHEM spectrometers are fully integrated UV-Vis and Vis-NIR systems for measuring absorbance and transmission of liquid samples in cuvettes. FLAME-CHEM is a great option for teaching labs and research facilities where users seek the performance and flexibility advantages of the Flame spectrometer in a compact, small footprint instrument. Each FLAME-CHEM system comprises a preconfigured Flame spectrometer, a direct-attach light source and a cuvette holder for 1 cm pathlength cuvettes – all in a single package. UV-Vis (200-850 nm) and Vis-NIR (350-1000 nm) models are available. Add OceanView spectroscopy software (purchased separately) to complete your system.

  • 10 Function Heavy Duty Industrial MultiMeter

    Extech EX503 - Extech Instruments Corporation

    The EX503 offers an array of must-have multimeter measurements including capacitance, frequency (dual sensitivity for electrical and electronic applications), diode test and continuity. Other features include Data Hold and Relative Hold, and manual- or auto-ranging modes. The latter automatically adjusts the measurement range based on the detected source such as electrical components and electronic equipment. The meter features 0.5 percent accuracy and a CAT IV-600-volt safety rating, protecting users even on outdoor wiring. Includes EX503 heavy-duty digital multimeter, double-molded test leads, magnetic hanging strap, 9-volt battery, carrying case, and user manual.

  • Measures Volatile Organic Compounds and CH2O/HCHO Concentrations in Real Time

    Extech VFM200 - Extech Instruments Corporation

    The VFM200 measures VOC (Volatile Organic Compound) and Formaldehyde concentrations in real-time. Fast response time, compact, easy-to-carry, and excellent for checking the indoor air quality of homes, offices, factories, hotels, schools and other indoor environments. Potential sources for VOCs include paints, finishes, adhesives, cigarette smoke, pesticides, personal care products, car exhaust, new furnishings, wall coverings, household cleansers, and cooking fuels. Chemicals include: Acetone, Ethylene Glycol, Formaldehyde, Xylene, 1,3-butadiene, Tetrachloroethene, Hydrogen Sulfide, Ammonia, Toluene, Benzene, Methylene Chloride, Perchloroethylene, and MTBE.

  • Capacitors - Polymer

    Vishay Intertechnology, Inc.

    Polymer capacitors feature a hight volumetric efficiency that allows smaller devices to have higher capacitance values. Vishay offers polymer capacitors in a variety of surface-mount case sizes for applications such as military, portable consumer, computer/ server, network infrastracture equipment, and many others.Polymer capacitors are constructed with a highly conductive polymer as the cathode system. For the anode, tantanum is used together with tantalum oxide dielectric. This construction gives polymer capacitors all the advantages of traditional tantalum capacitors while reducing equivalent series resistance (ESR) and eliminating manganese dioxide, which is a source of catastrophic failure in tranditional tantalum capacitors.

Get Help