Filter Results By:

Products

Applications

Manufacturers

Sources

The origin.


Showing results: 2581 - 2595 of 2909 items found.

  • PCI-6515, 64-Channel, ±30 VDC, 32 Sink/Source Inputs, 32 Sink Output, Bank-Isolated Digital I/O Device

    778835-01 - NI

    The PCI-6515 is an industrial digital I/O interface, with eight banks of isolated channels. You can wire each input bank in a source or sink configuration. With programmable power-up states, you can configure the initial output states in software, to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PCI-6515 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.

  • 4/8-CH 12-Bit 1 MS/s Analog Output Multi-Function DAQ PCI Express Cards

    DAQe-2500 Series - ADLINK Technology Inc.

    ADLINK DAQe-2500 series are high-speed and high-performance analog output multi-function DAQ PCI EXpress cards. The devices are able to update up to 8-CH, 12-bit analog outputs simultaneously at sustaining 1 MS/s. The reference sources and the output polarities are programmable on per channel basis, combining with the multiplying DAC architecture, ADLINK DAQe-2500 series DAQ cards can generate complex modulated analog signals. The hardware-based arbitrary waveform generation frees the CPU intervention even when all analog outputs are updating at full speed, and the lengths of waveforms are only limited by the system memory.

  • Multifrequency Clock Synthesizer - PMC

    Model 7190 - Pentek, Inc.

    - Simultaneous synthesis of up to 5 different clocks- 8 SMC clock outputs- Ideal for A/D and D/A converter clock sources- Typical phase noise: -125 dBc/Hz @ 1 kHz offset- All clocks are phase-locked to input reference signal- Input reference frequency of 5 or 10 MHz- Four quad VCXOs allow selection from 16 different base frequencies- Output clocks of 1, 2, 4, 8, or 16 submultiples of VCXO base frequencies- Output clock frequencies between 50 and 500 MHz- Control and status via PCI bus interface

  • Caraya Unit Tester

    JKI

    Caraya is a new experimental open source assertion and unit testing framework for LabVIEW. It takes a whole new approach to unit testing; your VI is your test. Caraya allows you to convert your manual test VIs you use for debugging into unit test cases with nearly no effort. Even running the tests is easy, just run the test case VI. Caraya significantly lowers the barrier for developers to write unit tests leading into improved overall code quality in real-world projects where developers don’t always have the luxury to write unit test cases first.

  • Calibrators

    Orbit Controls AG

    Orbit Controls calibrators are suitable as signal sources for the test field or the laboratory. They can be used as generators for calibrating and testing electronic measuring devices or assemblies both by manufacturers and by companies that have to carry out periodic calibration tasks due to the quality certification. They are also used in laboratories, development departments, repair and calibration services and much more. In addition to manual operation, all devices also have an RS232 or IEEE interface so that the calibrators can be integrated into an automatic measuring station. To calibrate multimeters with an LCD display, a camera is used which scans the display and automatically integrates the measured values ​​into the calibration software.

  • Thermal Night Vision Rifle Scope

    ThermoSight® R-Series - Teledyne FLIR

    Built by the leader in infrared technology, the FLIR ThermoSight R-Series is the world''''s first line of thermal night vision rifle scopes for non-game hunting starting under $3,500. Compact and easy-to-use, the ThermoSight R-Series combines the features you want with the thermal performance you expect. The ThermoSight R-Series is the ideal night vision scope because it detects heat energy, instead of light. Conventional image intensified (I2) night vision scopes require illumination from moonlight or other sources, and can''''''''t reveal what''''''''s hiding in the shadows or in low-contrast environments like the R-Series.

  • HBR3 Video Analyzer / Generator for DisplayPort Testing

    M41d - Teledyne LeCroy quantumdata

    The Teledyne LeCroy quantumdata M41d HBR3 Video Analyzer/Generator for DisplayPort Testing is a compact versatile test instrument offering entry level functional testing that can be extended through software licenses to a full compliance tester with sophisticated analysis and diagnostic capabilities. The M41d enables design and test engineers to validate their products for interoperability and reliability for the DisplayPort 1.4 video interface. The M41d is a flexible test instrument that can be upgraded from a functional tester for sources and sinks to a sophisticated analyzer and, if desired, can test full standards compliance, enabling developers to pre-test or self-test independently, reducing delays and costs during the product development cycle.

  • Test Compliance

    CTS Series 3.2 - AMETEK Programmable Power, Inc.

    The CTS Series is a complete, turn-key compliance test system for EN IEC 1000-3-2 (Harmonics) Including A14, EN IEC 1000-3-3 (Flicker) and various EN IEC 1000-4 AC immunity tests. Consisting of an AC power source, a power analysis conditioning system (PACS) and a PC based data acquisition system, the CTS provides a complete turn-key solution for IEC testing. The Windows™ based CTS software performs the IEC tests and generates detailed test reports. Comprehensive data files are stored on disk to allow post test analysis.

  • DC Power Supplies

    SFA Series - AMETEK Programmable Power, Inc.

    The SFA family builds on the industry leading Sorensen SGA series to provide a high power current source for laser diode applications. State of the art high power laser diodes require well-regulated current control to avoid catastrophic damage. Under anomalous operating conditions, excessive stored energy in the output circuit of the power supply can result in peak stresses that can permanently damage the device. Providing a constant current regulation mode only, the SFA’s low stored energy output minimizes damage potential for sensitive devices as well as enabling a current slew rate of up to 400 A/msec.

  • Fully Automatic Solar Cell Module

    Laminator-Ⅲ - Qinhuangdao Boostsolar Photovoltaic Equipment Co., Ltd

    1. Effective lamination area: 2200mm × 3600mm2. Dimensions: length 12380mm × width 3665mm × height 2164mm3. Heating method: heat conduction oil heating4. Compressed air source pressure: 0.6~0.8MPa5. Working vacuum degree: 100~40Pa6. Evacuation rate: 70L/S7. Temperature control accuracy: ±1.5°C8. Temperature control range: room temperature - 180°C9. Temperature uniformity: effective lamination area ≤±2°C10. Lamination cavity height: 30mm11. Evacuation time: depending on the process, it is recommended to be 5 to 8 minutes12. Upper cover stroke: 300mm

  • Fully Automatic Solar Cell Module

    Laminator-H - Qinhuangdao Boostsolar Photovoltaic Equipment Co., Ltd

    1. Model: BSL2236OAC-H2. Effective lamination area: 2200mm × 3600mm3. Dimensions: length 17410mm × width 3665mm × height 2164mm4. Heating method: heat conduction oil heating5. Compressed air source pressure: 0.6~0.8MPa6. Working vacuum degree: 100~40Pa7. Evacuation rate: 70L/S8. Temperature control accuracy: ±1.5°C9. Temperature control range: room temperature - 180°C10. Temperature uniformity: effective lamination area≤±2℃11. Lamination chamber height: 30mm12. Evacuation time: depending on the process, it is recommended to take 5 to 8 minutes13. Upper cover stroke: 300mm

  • Fully Automatic Solar Cell

    Module Laminator-H - Synopsys, Inc.

    1. Model: BSL2236OAC-H2. Effective lamination area: 2200mm × 3600mm3. Dimensions: length 17410mm × width 3665mm × height 2164mm4. Heating method: heat conduction oil heating5. Compressed air source pressure: 0.6~0.8MPa6. Working vacuum degree: 100~40Pa7. Evacuation rate: 70L/S8. Temperature control accuracy: ±1.5°C9. Temperature control range: room temperature - 180°C10. Temperature uniformity: effective lamination area≤±2℃11. Lamination chamber height: 30mm12. Evacuation time: depending on the process, it is recommended to take 5 to 8 minutes13. Upper cover stroke: 300mm

  • Tunable, Ultrafast TI: Sapphire Laser

    SPRITE XT - M Squared Lasers

    Sprite XT is a flexible ultrafast, femtosecond laser source. It delivers stability, reliability and productivity and is equally at home in the lab or as part of an OEM application. Choose your output power (up to multi-Watts), pulse width (femtosecond or picosecond models), wavelength range (fixed wavelength or tunable), and pulse repetition rate (<80 MHz to multi-GHz). All Sprite models are designed for alignment-free and maintenance-free operation and can be controlled from a web browser. It’s ideal for multi-photon excitation (MPE) and FLIM, quantum optics, time resolved spectroscopy, nonlinear optics, pump-probe experiments, microscopy, amplifier seeding, and electro-optic sampling.

  • Energy Storage/Backup Power

    ATX Networks Corp.

    Broadband service providers are challenged to reduce their carbon footprints and at the same time expand the reach and performance of their networks to meet escalating subscriber demand. The adoption of an eco-friendly energy storage and backup powering system based on hybrid supercapacitor technology enables service providers to achieve both goals while simultaneously improving network reliability and reducing capital and operational costs. ATX’s Areca™ Energy Storage Solutions include next-generation hybrid supercapacitor modules that offer significant improvements over existing standby power sources, such as valve regulated lead acid (VRLA) and Lithium-based batteries.

  • 3-Channel DC Current Datalogger

    Extech SD900 - Extech Instruments Corporation

    Extech's SD900 allows technicians to easily monitor and record DC mA values from 3 external sensors, transducers, and other sources using one meter. It also stores the time and date of when readings are taken. The logger features a large triple LCD display and records data on an SD card in an Excel®-ready format for easy transfer to a PC for analysis, trending, and archiving. Complete with six AAA batteries, SD memory card, Univeral AC Adaptor with multi-plugs (US, EU, UK, AUS), 3 input connect sockets, and mounting bracket.

Get Help