Filter Results By:

Products

Applications

Manufacturers

Solenoid

Act as a magnet when current flows through moving an iron core.


Showing results: 136 - 150 of 162 items found.

  • Single 8x2 1-Pole 16 Amp PXI Power Matrix

    40-552-002 - Pickering Interfaces Ltd.

    The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.

  • Single 4x4 1-Pole 16 Amp PXI Power Matrix With Loop-Thru

    40-552-011 - Pickering Interfaces Ltd.

    The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.

  • Single 8x2 1-Pole 16 Amp PXI Power Matrix With Loop-Thru

    40-552-012 - Pickering Interfaces Ltd.

    The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.

  • PXI 24 x DPST Reed Relays

    40-115-122 - Pickering Interfaces Ltd.

    Available in normally open (DPST & SPST) configurations. Connections are made via a front panel micro-D 96-pin male connector. For applications requiring improved bandwidth and crosstalk performance please look at our 40-120 and 40-125 range of shielded reed relay cards. General purpose reed relays are suitable for the construction of small switching networks, slaving up to larger switches or operating external devices (e.g. lamps, solenoids etc.). To simplify inter-relay wiring, interconnection points are built onto the circuit board easing the construction of complicated wiring.

  • PXI 8x4 1-Pole 10A Matrix With Loop-Thru

    40-551-101 - Pickering Interfaces Ltd.

    Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, this module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. This version of the 40-551 may be expanded to larger matrix sizes using cabling to daisy-chain the X and Y signals Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.

  • PXI 16 x SPST Reed Relay

    40-115-021 - Pickering Interfaces Ltd.

    Available in normally open (DPST & SPST) configurations. Connections are made via a front panel micro-D 96-pin male connector. For applications requiring improved bandwidth and crosstalk performance please look at our 40-120 and 40-125 range of shielded reed relay cards. General purpose reed relays are suitable for the construction of small switching networks, slaving up to larger switches or operating external devices (e.g. lamps, solenoids etc.). To simplify inter-relay wiring, interconnection points are built onto the circuit board easing the construction of complicated wiring.

  • PXI 8x4 Power Matrix, 2 Pole

    40-550-002 - Pickering Interfaces Ltd.

    Connections are made via a front panel 37-way D-Type male connector or two 20-way GMCT male connectors. Used for switching inductive/capacitive loads up to 5A at 250VAC. Power matrix modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids. Used for applications requiring switching of either mains voltage or direct current. These modules are fitted with electro-mechanical power relays, gold-flash over silver alloy. A spare relay is built onto the circuit board to facilitate easy maintenance with minimum downtime.

  • Single 4x4 1-Pole 16 Amp PXI Power Matrix

    40-552-001 - Pickering Interfaces Ltd.

    The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.

  • Walk / Drivable test facilities

    TW / CW series - Clima Temperatur Systeme

    Walk or drive-in temperature and climatic test chambers can be designed from CTS by a standardized grid system affordable in all sizes. The refrigeration performance data are adjusted here by our experienced sales and project engineers on your testing out. The walk / drive-chambers are ideal for larger components and finished products. CTS as a medium sized company attaches great importance to the detail quality of the equipment components, with only the best supplier products such as compressor and solenoid valves are used. Your resulting advantages are trouble-free long-term operation and thus no loss of valuable test time.

  • IP X5, X6 - Walk-In Rain Test Chamber

    ACMAS Technologies Pvt. Ltd.

    WEIBER designs and manufactures standard as well as customized water spray test chamber for evaluating various automotive, electrical and electronics items under water, rain or shower conditions. The chamber interrogates the performance of parts when subjected to water droplets.The system is based on the IP X5, X6 specification requirements, and can also accomplish individual automaker’s tests, as well as electrical-enclosure tests.Our system uses multiple control solenoids to vary the water's spray volume/pressure. A holding tank prepares the water to the desired temperature, if required. A pump ensures the water is delivered in the proper pressure range.

  • Power Switches

    SMX-2002 (Power) - AMETEK VTI Instruments

    The SMX-2002 is the only switch module in its class with the ability to switch up to 16A. Some applications include: AC line power switching, switching of DC or AC power supplies, control or driving relays for industrial machines (robotics, numerical control machines), automotive engine control, and solenoid switching. Since this module typically switches power to the UUT or interface, the SMX-2002 includes failsafe pins on the front panel which can be configured to open all relays when a failsafe signal is activated. This approach can instantly removes all power to the UUT or interface.

  • DC Gaussmeter

    GM1-ST - Alpha Lab, Inc.

    The Model 1-ST measures strength and polarity of magnetic fields up to 19,999.9 gauss. The sensor can easily fit in a .060 inch (1.5 mm) gap and is at the end of a 100 cm flexible cable. The sensor end can be bent if required for a variety of situations. Place the sensor on a magnet face to measure the field. With a resolution of 0.1 gauss, it can measure any tiny variation from magnet to magnet or it can detect if a given magnet has lost even a little strength. Bend the sensor in to a "L" to measure inside a DC solenoid tube. The 5 digit display requires neither auto nor manual range change, making it easier to use than older style 3 or 4 digit meters. Turn on the meter and immediately begin reading fields (updates 4 times per second). There is no setup required, making this the fastest, easiest gaussmeter available.

  • Carbon Dioxide Quality Control System

    CDQC - Teledyne Analytical Instruments

    Teledyne’s Carbon Dioxide Quality Control (CDQC) system offers an integrated package to continuously monitor impurities in carbon dioxide (CO2). The plug-and-play design allows for the user to select only the gases and features of interest to maximize cost benefit and space.Front door viewing windows allow for view of all analyzer displays, flow and pressure settings. Stainless steel tube fitting connections and NPT or metric electrical ports as required are conveniently located in a central location for ease of access. Sample conditioning, utility gas provisions and integral calibration gas solenoid valves are standard.

  • Keysight 32-Channel FormC/Form A General Purpose Switch for 34980A

    34937A - Keysight Technologies

    The Keysight 34937A is a general-purpose switch module for the 34980A Multifunction Switch/Measure Unit. It has 28 independent single-pole, double-throw (SPDT) 1A relays and 4 single-pole, single-throw (Form A) 5A relays. This module is used to cycle power to products under test, control indicator and status lights, and to actuate external power relays and solenoids. The Form C channels are 300V, 1A contacts and can handle up to 60W, and the Form A channels are 30VDC/250VAC, 5A contacts and can handle up to 150W. Standard 50-pin Dsub connectors allow for use with standard cables, terminal blocks, or mass interconnect solutions.

  • PXI 32 x SPDT Reed Relay

    40-110-121 - Pickering Interfaces Ltd.

    Our 40-110 and 40-115 range of reed relay switching modules are available in both Changeover (SPDT) and Normally Open (SPST & DPST) configurations. Connections are made via a front panel 96 pin male micro-D connector. For applications requiring improved bandwidth and crosstalk performance please look at our 40-120/125 range of shielded reed relay cards. General purpose reed relays are suitable for the construction of small switching networks, for slaving up to larger switches or for operating external devices (e.g. lamps, solenoids etc.). To simplify inter-relay wiring, interconnection points are built onto the circuit board thus easing the construction of complicated wiring.

Get Help