  • Air Particulate Counter

    CHY002 - Rinch Industrial Co.,Limited

    Using import semiconductor laser tube and import semiconductor photosensitive tube, assure sensitivity and response speed.Using import micropump,assure sampling volume steady,reduce noise.The key component-light scattering sensor obviously eliminate intracorporal stray light, improve SNR, test result more precise and reliable.The light scattering sensor got Chinese patent.Confidence measurement of this instrument,According to GB/T6167-2007 Standard,realize auto estimate clean class, creatively to auto estimate ≤9 location points clean class.1000 records stored, free to check previous data.User can optional PC data analysis software, realize data management.User can choose humidity sensor (optional accessories).Sampling volume display as digit, more intuitive and precise.“Measurement Number”function,realize multipoint management.Lithium battery,more safety,continuous working 6 hours.

  • Hydrographic Grade Deepwater Singebeam Echosounder

    DESO 5DS - Teledyne Marine RESON B.V.

    The DESO 5DS is a hydrographic grade deepwater singlebeam echosounder designed for reliable high performance in deep ocean surveys. It utilizes very high power transceiver electronics to survey the oceans down to 10km depth.The raw data record is stored in proprietary format by Teledyne’s own software and can be acquired, replayed, and analyzed similar to thermal paper records. Depth data is continuously generated on serial and network interfaces and can be recorded by hydrographic software.The DESO 5DS is based on our latest singlebeam sonar technology, designed as a precise and reliable survey tool for the survey from shallow waters to full ocean depth.The DESO 5DS utilizes the most robust automatic control and bottom detection algorithms available — providing you with precise depth information and brilliant water column profile even under the most challenging conditions.

  • IP Performance Testing Tools

    Omnicor

    Ethernet switches, routers and gateways have their distinct purposes and it is important to test their performance well. During R&D and DVT products are usually tested on L2/L7 while in production basic L2/L3 tests are usually sufficient. For those who follow testing methodology RFC 2544 and RFC 2889 are also available.IP traffic packet generators/analyzers for 10/100/1000 Mbps, gigabit and 10 gigabit with PoE options are the most important test instruments to ensure Ethernet switch or router product quality is verified. Gigabit TAP analyzers, media convertors, production test software suites and Ethernet cable emulators are additional tools used in conjunction with stream generators to help ensure fast development cycle and high quality. Our IP performance test systems are economic and known worldwide for excellence in quality and service support.

  • Electromagnetic Compatibility (EMC) Testing Capabilities

    Eurofins E&E

    Electromagnetic Compatibility testing analyzes the ability of electronic devices to operate as anticipated when in proximity to other electronic devices or in the presence of electromagnetic disturbances that interfere with their intended operation.We help you ensure EMC compliance and attain the needed EMC certifications by assisting you in maximizing accuracy, reducing testing cycles, and getting your products to market faster — from design conception to end-product completion even against the most demanding electromagnetic regulations.We understand that time to market is everything which is why our global testing capabilities and custom testing solutions utilize the latest technology and automation software, helping you meet demanding time-to-market needs. Our streamlined testing process brings your product from development to end use efficiently in accordance with government, regulatory, military, or industry standards based on your compliance needs.

  • Amp, Power Factor & VAR Recorder

    Varcorder - SensorLink

    The Varcorder measures and records Amps and Power Factor. A voltage constant is then applied in software to calculate VARs. The Varcorder uses the same current sensor technology as the original Ampstik. This patented amp sensor does not use magnetic materials and has no moving parts. The opening of the sensor is electronically closed, and external currents are electronically rejected. The accuracy, external current reject, and range of currents measured by the patented amp sensor substantially exceed the performance of the best clamp-on sensors. The true power factor is calculated by measuring the electric field in comparison with the current reported from the amp sensor. The key feature of the unit is the ability to leave it deployed on the line to record readings every 15 minutes for 90+ days. It easily attaches to the line with a standard shotgun style hotstick. Once on the line, it immediately begins to collect and record the current and power factor on the line.

  • Bruker’s Innovative Mass Spectrometry Solutions

    Bruker Corporation

    Discover new ways to apply mass spectrometry to today’s most pressing analytical challenges. Innovations such as Trapped Ion Mobility (TIMS), smartbeam and scanning lasers for MALDI-MS Imaging that deliver true pixel fidelity, and eXtreme Resolution FTMS (XR) technology capable to reveal Isotopic Fine Structure (IFS) signatures are pushing scientific exploration to new heights. Our mass spectrometry solutions enable scientists to make breakthrough discoveries and gain deeper insights.Our industry leading software solutions such as SCiLs Lab for MS Imaging, FDA cleared microorganism reference library for the MALDI Biotyper, Biopharma Compass 2.0, and Toxtyper are examples our solutions doing the work for you.  Bruker's product lines include the following technologies: FTMS, rapifleX MALDI-TOF/TOF, MALDI Biotyper Systems, timsTOF UHR-QTOF, Toxtyper, Triple Quadrupole, HDX Solution, TargetScreener HR

  • ARINC 664 Part 7 Test & Simulation Interface for PCI Express

    PCIe-C664-V2 - Avionics Interface Technologies

    Supports IEEE 802.3 10/100/1000 Mbit/s Full-Duplex Ethernet links - Utilizes SFPs to support both copper and optical interfaces - Simulates multiple ARINC 664 End Systems - VL traffic shaping and input VL redundancy management - Supports up to 4K Output VLs and 4K Input VLs - Supports up to 16K Sampling & Queuing output message ports and up to 16K input Sampling & Queuing message ports - ARINC 653, UDP, IP protocols managed onboard - IRIG-B time code encoder/decoder - Automatic message sequencing & periodic data generated onboard - Error Injection including Runt Frames, Short IFG, and Invalid MAC FCSDevice driver support: Windows, Linux, LabVIEW Real-Time (others on request) - Compatible with AIT’s Flight Simulyzer GUI Bus Analyzer Software

  • ARINC 664 Part 7 XMC Interface Module

    XMC-664-V2 - Avionics Interface Technologies

    Supports IEEE 802.3 10/100/1000 Mbit/s Full-Duplex Ethernet links - Utilizes SFPs to support both copper and optical interfaces - Simulates multiple ARINC 664 End Systems - VL traffic shaping and input VL redundancy management - Supports up to 4K Output VLs and 4K Input VLs - Supports up to 16K Sampling & Queuing output message ports and up to 16K input Sampling & Queuing message ports - ARINC 653, UDP, IP protocols managed onboard - IRIG-B time code encoder/decoder - Automatic message sequencing & periodic data generated onboard - Error Injection including Runt Frames, Short IFG, and Invalid MAC FCSDevice driver support: Windows, Linux, LabVIEW Real-Time (others on request) - Compatible with AIT’s Flight Simulyzer GUI Bus Analyzer Software

  • Digital I/O Device

    NI

    The Digital I/O Device supports channel, current, and voltage options to help you automate applications. This module features programmable input filters to remove chatter, noise, glitches, and spikes on inputs, and these filters also provide debouncing for digital switches and relays. You can use the module to perform safe operation when connected to pumps, motors, and other industrial actuators or machinery using the included power-up states. The module also provides a fail-safe mechanism that monitors for computer or application crashes and place the system in a state to ensure safe recovery. Additionally, some models include high-voltage, high-current, and isolation options to ensure the product can work safely in many environments.The Digital I/O Device includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • Produce Quality Meter

    F-750 - Felix Instruments

    The F-750 Handheld Brix & Dry Matter Meter uses near-infrared (NIR) spectroscopy to estimate quality metrics such as dry matter, Total Soluble Solids (TSS or brix), titratable acidity, and color. Working like a high-powered flashlight, the F-750 sends particles of light into a commodity, then measures the NIR light interactance with molecular components inside of the commodity to quantify user-selected traits. The F-750 has a wide range of applications, from determining optimal harvest timing by assessing fruit maturity, to providing an objective analysis of produce quality of fruit in packing houses and upon import. The F-750 is a handheld, fully integrated system, allowing users to operate it out in the orchard or inside the QA lab. Its simple, intuitive user interface makes it easy for anyone to use, while its model building software makes it customizable and versatile.

  • Modbus Register Converter

    Model 2390 - ICS Electronics

    * Converts Modbus Registers and variables for replacement Modbus devices.* Maintain existing software when upgrading Modbus systems.* Provides serial control of Modbus RTU devices from any ASCII source.* User defined Register Conversion Table supports all Modbus RTU devices.* Internal Register Conversion Tables for Watlow F4-to-EZ-ZONE and F4-to-F4T conversion.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes baud rate conversion capability.* Uses SCPI commands to load the Conversion Table and set serial settings.* Small metal case mounts on a DIN rail or on any flat panel.* 239x Table Loader Program uploads the 2390 Register Conversion Table from an Excel csv file.* 239x Serial Keyboard Program provides instant control of the 2390 and Modbus Slave Devices without writing a program.

  • Measurement System for ESD Protection

    SampleProtect - Oxford Instruments plc

    The SampleProtect measurement system is ready to go, and comes complete with Oxford Instruments’ Cryofree bottom loading cryostat – the OptistatDry BLV, Zurich Instruments’ MFLI Lock-in Amplifier, a specially designed ESD break-out box and high quality measurement grade cables. The patent-pending puck style mounting from Oxford Instruments provides safe installation of your samples. The MFLI 500 kHz Lock-in Amplifier (capable of 500 kHz demodulation as standard) with MF-MD multi-demodulator capability brings the benefits of high performance signal processing at low and medium frequencies. The differential voltage and current inputs of the MFLI are optimised for low noise operation and the high oversampling rate ensures an even better signal to noise ratio. Zurich Instruments’ unique LabOne® control software provides a toolset including an integrated oscilloscope, a spectrum analyser, a plotter and a parameter sweeper.

  • The Leading Measurement System for the Analysis of Porous Materials

    ELWIS - Autoneum Holding AG

    ELWIS (Evaluation of Light Weight Impedance System) offers a full and rapid characterization of porous materials based on the analysis of a single sample. The ELWIS system consists of the ELWIS-A and ELWIS-S components which can be used independently from each other although both applications are needed for a complete material simulation.ELWIS-A measures acoustic parameters that are needed to evaluate the acoustic performance of sound insulation and sound-absorbing multi-layer materials. An additional impedance tube for absorption measurements at higher frequencies is available for ELWIS-A.ELWIS-S measures structural parameters that are needed to simulate the dynamic and acoustic behavior of sound packages in the medium to low frequency range (including the "Poisson Ratio" for foam materials).ELWIS is very easy to operate: Thanks to its user-friendly software, the system can also be used to obtain reliable results by users with only limited experience in the characterization of porous materials.

  • Precision I/V Source

    Model 155 - Lake Shore Cryotronics, Inc.

    To reliably characterize developing semiconductor materials and devices, you need high quality current or voltage sources to excite samples. A cleaner (i.e., lower noise) excitation signal enables better measurement of the sample’s response. The MeasureReady™ Model 155 precision I/V sources are ideal for electronic material characterization and other demanding scientific applications requiring a precise, low-noise supply of current or voltage. Supplying 1 W maximum from DC to 100 kHz over a broad output range, these sources provide a solid foundation for I/V curve, Hall effect, and other fundamental measurements. With online software updates, your instrument will always have the most current capabilities. As Lake Shore introduces new options in the future, you can purchase and download them to your instrument. This allows the Model 155 to grow as your measurement needs evolve.

  • Dual Channel Clock Driver Card

    PI-41400 - Pulse Instruments

    The PI-41400 is a dual channel Clock Driver card capable of operating up to 190 MHz into a 50-ohm load and up to 80 MHz at an amplitude of 8 volts into a 1-megohm load. Into a high impedance load the output voltage range is from a –3 volts to 8 volts with the output pulse amplitude ranging from 0.5 V to 9 V. When driving a 50 load the voltage range is –1.5 volts to 4.5 volts with the output pulse amplitude ranging from 0.25 V to 4.5 V. The rise and fall times of the output pulse are variable from 1.2 ns to 9 ns into a 50-ohm load and <5 ns to 9 ns into a HiZ load. The output pulse amplitude and the load being driven determine the range of variability. The driver output can be set for tri-state operation and the output polarity can be set for ‘Normal’ or ‘Inverted’ operation through software.