Shunts
An Instrument Shunt is a resistor connected in parallel with a measuring device to move the current range beyond a particular value for which the instrument is capable of measuring directly.
See Also: Current Shunts
-
product
High Frequency Clock Divider Board
Alliance Support Partners, Inc.
Clock Divider is designed to divide high frequency signals, up to 2.5GHz, from 4 to 256 times. It will accept single ended (Unbalanced) or differential (Balanced) signals with amplitudes as little as 100mV rms. The clock division is controlled by 4 shunt jumpers. The circuit can be disabled and the divide by counter reset with 2 control signals. The on board regulator will accept voltages from 4.85 to 15.0V. The output is capable of driving 700mV Peak to Peak into 50 Ohms.
-
product
Load Cell Indicator
9820
Bipolar, 5-digit display featuring 2000Hz high-bandwidth, +/-10V analog output, front-panel shunt calibration and tare, peak and valley monitoring. Sensor connection is via a removable screw-terminal connector.
-
product
Precision AC/DC Active Current Shunt
2575A
A versatile, powerful calibration tool, the 2575A Precision AC-DC Active Current Shunt measures both AC/DC current and works as a standard for low-level resistance calibration requirements.
-
product
Shunts
WSM alternating current measuring resistors have compared with traditional direct current shunt resistors with coaxial voltage tap significantly better high-frequency transmission characteristics. This resulted from a production engineering very complicated structural design of the active part.ISM pulse current measuring resistors allow the metrological recording of the time curve fast current changes large amplitude in the nanosecond range. The ISM are designed for the pulse current measurement with broadband oscilloscopes.
-
product
Transient Voltage Suppressors (TVS)
A transient voltage suppressor (TVS) is an avalanche diode specially designed to clamp overvoltages and dissipate high transient power surges. ST’s Transil™ protection devices are able to shunt a high current surge for a short duration.
-
product
Repeated Charge Discharge Test Set
The IS 13341 : 1992 has laid down the requirements for Ageing Test, Self-Healing Test and Destruction Test on Shunt Capacitors of the self healing type for AC Power Systems. The Ageing Test is to be performed at a specified voltage of 1.25 times the rated voltage for 750 hours. The test is to be followed with a repeated discharge cycle test which involves charging of the capacitor to a DC voltage and discharge of the same through an Inductance. Sivananda Electronics has developed this equipment for the benefit of capacitor manufacturers, for the first time in India.
-
product
Isolation Amplifiers
Isolation Amplifiers provide power supply designers with a higher performing, single chip alternative to isolation techniques based on optocouplers and shunt regulators. Analog Devices ADuM3190 and ADuM4190 isolated error amplifiers have a 400 kHz bandwidth, with 0.5% typical initial accuracy at 25°C and 1% total accuracy over the extended temperature range of –40˚C to +125˚C. This provides manufacturers of ac-to-dc and dc-to-dc power supplies with a significant upgrade in speed and operating temperature range, as well as a 5× improvement in transient response.
-
product
Series Voltage References
Analog Devices offers a broad line of series voltage references with low dropout, low power, and excellent line regulation. These devices are voltage references that are functionally similar to a three-terminal regulator. Some series voltage references are designed to also operate in shunt mode by biasing the output pin and leaving the input pin open circuit. Series mode voltage references have the advantage that they draw only load and quiescent current from the input supply.
-
product
Current Probe
DCP-BTA
Vernier Software & Technology, LLC
The Current Probe measures DC and low-frequency AC currents up to 600 mA. Use Current Probes in combination with Differential Voltage Probes to investigate Ohm's Law and explore series and parallel circuits. The 0.1 shunt resistor minimizes changes to your circuit. If currents will exceed 1 A, use the High Current Sensor.
-
product
PXIe-4330, 25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module
781346-01
25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4330 is a simultaneous input module that provides integrated data acquisition and signal conditioning for bridge-based sensors. The PXIe‑4330 includes increased accuracy, high data throughput, and synchronization features, making it ideal for high-density measurement systems. To remove noise, the PXIe‑4330 offers antialiasing and digital filters per channel. Each channel also features an independent, programmable excitation voltage. Additionally, the PXIe‑4330 provides remote sensing, internal bridge completion, and shunt calibration options per channel.
-
product
High-Voltage Isolation Amplifier
Knick Elektronische Messgeräte GmbH & Co. KG.
Measurement of DC or AC voltages up to () 3600 V and of large DC currents to about () 20 kA with shunt resistor or directly in the device to () 5A DC and AC. Variants with calibrated range selection.
-
product
Precision Current Shunt
Has five precision selectable Ultra stable Current Shunts which ranges from 0.0001 to 1Ω. The Shunt T/C is less than 10ppm, and the internal current meter will measure from 1μA to 1000Amps.