Filter Results By:

Products

Applications

Manufacturers

Sensors

detect a physical event then translate to a representative analog signal.

See Also: Measurement, Detectors, Meters, Transducers


Showing results: 3136 - 3150 of 3239 items found.

  • Advanced Handheld Partial Discharge Detector for Electric Power Equipment with Multi-Sensor and Cloud Diagnostic Technologies, Data Management Software, and Test Management App

    PDetector - Power Monitoring and Diagnostic Technology Ltd.

    The PDetector is an ideal device for On-Line Partial Discharge (OLPD) testing of MV and HV equipment which employs all 5 types of OLPD sensor technology: Ultra-High Frequency (UHF), Acoustic Emissions (AE), Ultrasonic, High Frequency Current Transformer (HFCT), and Transient Earth Voltage (TEV). The information from multiple sensors gives the PDetector the versatility to detect all types of PD in all types of substation apparatus. The exact type of PD activity can be determined effectively using multiple on-screen data spectrum analysis. The PDetector greatly simplifies and standardizes the routine OLPD testing procedure by using the Intelligent Patrol function, the PDetector App, and the PMDTCloud. It is a very powerful and helpful tool for substation operators to conduct routine testing in a substation quickly, to determine what the issue is, and where it is located.

  • Pitot Static Tester / AoA TESTER

    ADSE 744 - ATEQ Aviation

    This tester was specifically designed for the new-generation pitot tubes that integrate sensing probes, pressure sensors and powerful air data computer processing to provide all critical air data parameters including Pitot and static pressure, airspeed, altitude, and angle of attack. This Pitot Static tester is designed primarily for flightline use to cover the testing of all barometric and manometric pressure instrument systems. The AoA Channel behaves as a second Ps channel, in order to create a differential pressure between the 2 Ps Channel, allowing to performsimulations of different Angles of Attack. The large touch screen display, with on-screen help, enables all checks to be carried out easily on the flight deck or in the cockpit, by a single operator. The ADSE 744 is robust and housed in amobile weatherproof case. An attached bag contains the pressure hoses and electrical cables.

  • Displacement Transducers

    Procter & Chester Measurements Ltd

    Pressure: Measures gas or liquid pressure. Pressure is an expression of the force required to stop a fluid from expanding. The transducer generates a signal from the pressure imposed upon it. Torque: Measures the torque (or twisting motion) on a static or rotating system. The static torque element has little movement and therefore more economic to manufacture and purchase. Rotary or dynamic torque is more complicated as the signal needs to be transferred using slip rings, wireless telemetry or rotary transformers/inductance technology so that the strain gauged shaft can continuously rotate. Displacement: Measures distance. The displacement transducers that PCM offer are slightly different to standard units. They have a strain gauge/wheatstone bridge. The benefit here is that if the customer has existing electronics that uses strain gauge/load cell technology, they can use them with these sensors.

  • 28-CH PPI Module

    ND-6058 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 3-CH RTD Input Module

    ND-6013 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 15-CH Isolated Digital Output Module

    ND-6056 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 8-CH Analog Input Module

    ND-6017 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 8-CH Relay Output Module

    ND-6063 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • RS-422/RS-485 Repeater

    ND-6510 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • Relay Output & Digital Input Module

    ND-6060 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • RS-232 to RS-422/RS-485 Converter

    ND-6520 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • Partial Discharge Expert Diagnostic and Location System

    PDExpert - Power Monitoring and Diagnostic Technology Ltd.

    The PDExpert is PMDT's third level of Partial Discharge (PD) Expert Diagnostic and Location System. It is a powerful, portable, multi-channel system of impeccable design used to analyze and pinpoint PD signals coming from a power asset within centimeters while the power system is energized. The system consists of UHF, AE, HFCT and ultrasonic sensors, one advanced UHF/PD signal processing unit, one oscilloscope, filters and other accessories.The system employs ultra-high speed data acquisition and advanced digital signal processing technologies, compares the UHF, AE and HFCT signals of different frequency ranges to determine if it is PD or noise, and locates the source in power assets accurately by utilizing Acoustic-Electromagnetic Combination Location Technique, time Difference of Signals' Arrivals (TDOA), and 3D Positioning Technology.

  • Situational Understanding Mission Intelligent Technology

    SUMIT360™ - Teledyne FLIR

    The SUMIT360™ provides military armored vehicle operators with an innovative, 360 degree view of the environment around the vehicle utilizing advanced sensor technology to improve threat and obstacle detection that could pose a threat to ground forces, and their mission. Equipped with powerful multi-spectral sensors in each module, the system uses on-board processing to form seamless, stitched images to provide a full field of view in any terrain, and virtually any conditions, day or night. With additional target detection and identification capability, the system can also be paired with advanced analytics and Artificial Intelligence (AI) to provide vehicle crew, and transported troops a threat detection and classification to provide critical decision support before opening the hatch. The system also provides the ability to support remote or optionally manned configurations.

  • USB to RS-422/RS-485 Converter

    ND-6530 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • Torque Transducer

    T12HP - HBM, Inc

    One torque sensor, multiple functions only T12HP can do this. Its superior basic accuracy guarantees precise values over the entire measurement range. This results in the FlexRange capability that only T12HP can provide without the need to switch the measuring range like so called dual range sensors do. The non-contacting transducer combines the flexibility of digital signal conditioning with the measurement accuracy of a carrier-frequency amplifier without data or accuracy loss. T12HP Assistant and CAN parameterization are user-friendly tools made available to allow easy configuration. In combination with the TIM-EC interface module for EtherCAT and TIM-PN for PROFINET the torque and rotational speed signals can be integrated with cutting-edge test bench systems via the frequency interface with to date unknown precision and maximum performance and in a highly flexible manner.

Get Help