Filter Results By:

Products

Applications

Manufacturers

Sensors

detect a physical event then translate to a representative analog signal.

See Also: Measurement, Detectors, Meters, Transducers


Showing product results. 2986 - 3000 of 3227 products found.

  • High Performance Polyphase Energy Metering AFE w/ Power Quality Analysis

    ADE9000 - Analog Devices Inc.

    The ADE9000 is a highly accurate, fully integrated energy-metering device. Interfacing with both current transformer (CT) and Rogowski coil sensors, the ADE9000 enables users to develop a three-phase metrology platform, which achieves high performance for Class 1 through Class 0.2 meters. Power quality features enable advanced meter designs with fast rms measurements and power quality level monitoring for EN50160 compliance. The ADE9000 integrates seven high performances ADC’s, a flexible DSP core. An integrated high-end reference ensures low drift over temperature with a combined drift of less than ±25 ppm/°C max for the whole channel including PGA and ADC.

  • High-Performance Surface Plasmon Resonance System

    SPR-32 - Bruker Daltonics

    Features like ‘Frame Inject’ allows for turn-key sample processing protocols and customized workflows created together with pharmaceutical customers. The faster data analysis and highly intuitive user interface combine to deliver an industry-leading SPR throughput of 10,000 control-substracted binding measurements. Combining flexible 8-needle sample delivery with a 32-sensor detection array laid out in 8 detection flow cells, enables 4 sensors per flow cell, an important advantage for controlled, high-throughput SPR methods. The patented Hydrodynamic Isolation™ technology enables ‘Any Sample, Any Sensor, Any Time’, making it the preferred platform for screening, kinetics, thermodynamics and epitope mapping for pharmaceutical applications.

  • Industrial Calibrators

    Fluke Calibration

    A temperature calibrator, often called a thermometer calibrator, is used to correct inaccuracies in installed thermometers and temperature sensors, because temperature measurement is a critical parameter in many industrial processes. Although simulators are sometimes called temperature calibrators or thermometer calibrators and may be used to provide thermometer calibration for the electronics in an installed system, a temperature source with a calibrated reference sensor is still required to provide a complete and meaningful calibration. Fluke Calibration industrial and field temperature calibrators include: Metrology Wells; Field Metrology Wells; field dry-well calibrators; handheld dry block calibrators; Micro-Baths; large target infrared calibrators; field IR calibrators; ice-point dry-well; and thermocouple furnaces.

  • Isolated Process Control Signal Conditioning Products

    SCIM7B - Bee Instruments

    SCIM7B Isolated Process Control Signal Conditioning Modules provide a complete selection of backpanels DIN rail mounting accessories, interface cables and rack mounting hardware.Each SCIM7B module provides a single of isolated analog input or output. Various input modules accept analog voltage or current signals from all types of field sensors and sources, filter, isolateamplify, linearize and convert these input signals to high-level analog outputs suitable for use in a process control system. Output modules accept high-level analog voltage signals from a process control system, then buffer, isolate, filter, convert and amplify before providing a current or voltage output to a fielddevice.

  • LED Burn-In Test

    LXinstruments GmbH

    Burn-in system, based on LXI instrumentation, for concurrent testing of up to 80 DUTs in a climatic chamber. Devices to be tested include modern light emitting diodes and LED modules.The system consists of 2 control cabinets, each with 40 independent supply and measurement channels. Each channel can be configured individually via the operator software (current or voltage, including the relevant limit values). The software supports logging of current and voltage values for each DUT on all 80 channels with a sampling rate of <1s. Additionally, the software and system also support digital I/O channels, e. g. for controlling the climatic chamber. Inputs for connecting temperature sensors are also provided.

  • Machine Vision Camera - 7.1 MP, 112 FPS, Sony IMX420, Color, with 10GigE Adapter

    Oryx 10GigE - Teledyne FLIR

    The award-winning Oryx 10GigE camera family allows systems designers to take advantage of the latest sensors by supporting transfer speeds of up to 10 Gbit/s enabling capture of 4K resolution, 12-bit images at over 60 FPS. Oryx features include IEEE1588 clock synchronization and full compatibility with several popular third-party software supporting GigE Vision. Reliable image transfer at high bandwidth is further improved with Myricom bundles and packet resend feature. Oryx’s 10GBASE-T interface is a proven and widely deployed standard that provides reliable image transfer at cable lengths over 50 meters on inexpensive CAT6A, and up to 30 meters on CAT5e.

  • Magcam MiniCube1D

    MagCam NV

    Magcam's MiniCube1Dmagnetic field camera provides quantitativeBz magnetic field mapping in a 12.7mm x 12.7mm 2D planewith 0.1mm spatial resolution, measured at high speed. The camera is based on Magcam's unique integrated 2D Hall sensor array technology, featuring more than 16000 microscopic magnetic field sensors on one single chip. Each sensor independently measures the local magnetic field, resulting in quantitative2D magnetic field maps with high spatial resolution, measured athigh speed. These magnetic field maps contain a large amount of information about the magnet's properties, which can be extracted using Magcam's powerful MagScope measurement and analysis software.

  • Network Attached Storage / Fibre Channel

    CNS4-FC - Curtiss-Wright Defense Solutions

    The Compact Network Storage 4-Slot - Fibre Channel (CNS4-FC) is the perfect storage solution for programs looking to modernize systems using legacy Fibre Channel (FC) or Serial-Attached SCSI (SAS) drives. Providing many of the benefits provided by the CNS4, the CNS4-FC brings newly added support for FC protocol plus other network protocols like Network File Server (NFS), Common Internet File System (CIFS), File Transfer Protocol (FTP), Hypertext Transfer Protocol (HTTP), and Internet Small Computer System Interface (iSCSI) making it ideal for sharing critical data in a deployed network for mission platforms that were developed with sensors utilizing FC as the protocol.

  • NI-9231 and cDAQ-9171 USB Sound and Vibration Measurement Bundle

    865665-01 - NI

    NI-9231 and cDAQ-9171 USB Sound and Vibration Measurement Bundle - The USB Sound and Vibration Measurement Bundle with NI-9231 and cDAQ-9171 includes the NI-9231 C Series Sound and Vibration Input Module and the cDAQ-9171 CompactDAQ Chassis for sound and vibrations measurements. … This bundle provides a portable, USB-based sensor measurement system that helps you measure signals from integrated electronic piezoelectric (IEPE) and non IEPE sensors such as accelerometers, tachometers, and proximity probes. The included NI-9234 features 8 channels with built-in anti-aliasing filters that automatically adjust to your sample rate. Additionally, the bundle supports simultaneous sampling and high dynamic range measurements necessary for modern measurement microphones and accelerometers.

  • NI-9234 and cDAQ-9171 USB Sound and Vibration Measurement Bundle

    865664-01 - NI

    NI-9234 and cDAQ-9171 USB Sound and Vibration Measurement Bundle - The USB Sound and Vibration Measurement Bundle with NI-9234 and cDAQ-9171 includes the NI-9234 C Series Sound and Vibration Input Module and the cDAQ-9171 CompactDAQ Chassis for sound and vibration measurements. … This bundle provides a portable, USB-based sensor measurement system that helps you measure signals from integrated electronic piezoelectric (IEPE) and non IEPE sensors such as accelerometers, tachometers, and proximity probes. The included NI-9234 features 4 channels with built-in anti-aliasing filters that automatically adjust to your sample rate. Additionally, when used with NI software, the bundle provides processing functionality for condition monitoring such as frequency analysis and order tracking.

  • Optical Rotary Encoders

    BEI Industrial Encoders

    Optical sensing technology is the most precise and offers the highest resolution of the position sensing technologies. Rugged construction and years of field proven service makes BEI optical rotary encoders ideal for operating in harsh industrial environments including oil well drilling, machine control, agricultural machinery, web process control, robotics, elevators, construction equipment, cranes, motor feedback and any closed loop control systems. BEI optical encoders are available as incremental, absolute single-turn, and absolute multi-turn. BEI Sensors programmable encoders offer resolution flexibility to match changing needs while also saving on inventory costs and reducing machine downtime.

  • Sensor for Filament Inspection

    EyeFI - Eye Vision Technology GmbH

    EVT presents the EyeFI - the sensor for the inspection of filaments. The sensor contains two cameras with an Aptina sensor and S-Mount lenses. The cameras are perpendicular to each other. It is therefore possible to inspect two sides of the filament, which means that the EyeFI can detect if the filament is out-of-roundness. Additionally the errors and defects can be detected. For example the occurring flaws are point-shaped or partly flaked, or point-shaped and transverse, or also looking like a longitudial rib, or only spots in different shapes. The defects can be detected with the EyeFI sensor. The EyeFI contains board cameras with sensors from Aptina, the IoCap and an evaluation processor. The housing is about 14x10x4 cm in size. The IoCap is the image-capture-IO-board, which is designed and developped by EVT.

  • Virtual Receiver/Exciter Generalized Simulator

    VREX - FishEye Software, Inc.

    Electromagnetic sensors include a “front-end” that generates and receives the electromagnetic waves through a subsystem known as a Receiver/EXciter (REX). They also include a “back-end” that performs signal and data processing, typically implemented in software. These separate subsystems must be designed and developed separately, then integrated together. The development of the overall sensor is slowed and complicated by the problems that show up for the first time at integration testing. This is due in large part to the interdependencies of these subsystems that cannot be effectively tested during development. Later, software patches, configuration upgrades, waveform changes, and technology refresh become substantially more expensive because they can only be verified by traveling to the operational site to connect with the actual front-end hardware.

  • Wireless Temperature And Humidity Data Logger

    ThermaSense - McGan Technology

    ThermaSense is a Wireless temperature and humidity sensor with external humidity and RTD based temperature sensors, the device provides a fast response time for both parameters, Functions include starting, stopping and downloading from the device wirelessly. Data can be provided in real time back to a central PC, or the device may be downloaded at periodic intervals. The digital display provides the current reading for both the humidity and temperature levels with a quick view of minimum, maximum and average statistics of the logged data. An audible buzzer and LED alarm indicator alarms when either parameter is above or below the threshold set. Email and text alarms can also be configured and sent from within the software.

  • X-RAY Cameras Based On CCD

    XiRAY - XIMEA GmbH

    *High resolution direct phosphor imaging, ideal for Micro CT*Ultra-low readout noise with CCD and especially the new sCMOS sensors*Crystal clear 14 bit/pixel images*Partial readout and binning modes for enhanced sensitivity and higher speed*Non-linearity over full dynamic range <2% (of full scale) to 95% of full scale*External triggering, LVTTL*Low power consumption 6 Watt with Cooling or 2W without*Antiblooming, Enhanced Statistical Extra-Mural Absorption*Radiation hardened, Support of Energy levels 7 to 100keV*Measures just 63 x 63 x 46 mm*Peltier TE Cooled with Heatsink and optional fan

Get Help