Showing results: 76 - 90 of 117 items found.
-
8490D -
Keysight Technologies
The Keysight 8490D coaxial fixed attenuator provides precision attenuation, flat frequency response, low SWR over broad frequency range at a low price. The attenuator is available in nominal attenuations of 3 dB and 6 dB, also 10 dB increments from 10 dB to 40 dB. This attenuator is swept-frequency tested to ensure they meet specifications at all frequencies. Calibration points are provided on a nameplate chart attached to each unit.
-
8491A -
Keysight Technologies
The Keysight 8491A coaxial fixed attenuator provides precision attenuation, flat frequency response and low SWR over broad frequency ranges. The attenuator has type-N connectors and is available in nominal attenuations of 3 dB and 6 dB, as well as 10 dB increments from 10 dB to 60 dB. This attenuator is swept-frequency tested to ensure specification compliance at all frequencies. Calibration points are provided on a nameplate chart attached to each unit.
-
8493B -
Keysight Technologies
The Keysight 8493B coaxial fixed attenuator provides precision attenuation, flat frequency response, low SWR over broad frequency range at a low price. The attenuator is available in nominal attenuations of 3 dB and 6 dB, also 10 dB increments from 10 dB to 30 dB. This attenuator is swept-frequency tested to ensure it meets specifications at all frequencies. Calibration points are provided on a nameplate chart attached to each unit.
-
8493A -
Keysight Technologies
The Keysight 8493A coaxial fixed attenuator provides precision attenuation, flat frequency response, low SWR over broad frequency range at a low price. The attenuator is available in nominal attenuations of 3 dB and 6 dB, also 10 dB increments from 10 dB to 30 dB. This attenuator is swept-frequency tested to ensure it meets specifications at all frequencies. Calibration points are provided on a nameplate chart attached to each unit.
-
8493C -
Keysight Technologies
The Keysight 8493C coaxial fixed attenuator provides precision attenuation, flat frequency response, low SWR over broad frequency range at a low price. The attenuator has APC-3.5 connectors and is available in nominal attenuations of 3 dB and 6 dB, also 10 dB increments from 10 dB to 40 dB.This attenuator is swept-frequency tested to ensure it meets specifications at all frequencies. Calibration points are provided on a nameplate chart attached to each unit.
-
8487D -
Keysight Technologies
Excellent SWR for reducing mismatch uncertainty Accurate calibration and traceability to US National Institute of Standards and Technology (NIST) millimeter-wave sensor calibration Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters, plus the E1416A VXI and discontinued 70100A and 43X power meter Accurate average power measurements over -70 to -20 dBm Frequency range 50 MHz to 50 GHzDiode power sensing element
-
8491B -
Keysight Technologies
The Keysight 8491B coaxial fixed attenuator provides precision attenuation, flat frequency response and low SWR over broad frequency ranges. The attenuator is available in nominal attenuations of 3 dB and 6 dB, as well as 10 dB increments from 10 dB to 60 dB. It has type-N connectors with a maximum frequency of 18 GHz. This attenuator is swept-frequency tested to ensure specification compliance at all frequencies. Calibration points are provided on a nameplate chart attached to each unit.
-
346CK40 -
Keysight Technologies
The Keysight 346CK40 is the ideal companion to Keysight´s noise figure solutions when working on high frequency applications. Since it is broadband (1 GHz to 40 GHz), it eliminates the necessity for several sources at different frequency bands. The low SWR of the noise source greatly reduces measurement uncertainty, which are commonly reflections of the test signals. This is a coaxial noise source with a 2.4 mm coaxial connector. ENR typically 14 dB at 1 GHz, decreasing to 5 dB at 40 GHz (typical).
-
346CK01 -
Keysight Technologies
The Keysight 346CK01 is the ideal companion to Keysight´s noise figure solutions when working on high frequency applications. Since it is broadband (1 GHz to 50 GHz), it eliminates the necessity for several sources at different frequency bands. The low SWR of the noise source reduces a major source of measurement uncertainty, which are reflections of the test signals. This is a coaxial noise source with a 2.4 mm coaxial connector. ENR typically 20 dB at 1 GHz, decreasing to typically 7 dB at 50 GHz.
-
Taiwan Nissei Sokki Co
Measuring antenna SWR ratio with graphic display in a selected frequency range.Measuring antenna Impedance ( Z = R + j X )Measuring antenna resistance RMeasuring antenna reactance X, all the above with graphic display in a selected frequency range.Quick search for antenna resonance frequencyVery suitable for antenna measurement and adjustment.Portable and small size.Easy and intuitive operation
-
U9397C -
Keysight Technologies
The Keysight U9397C solid state switch maximizes your frequency range from 300 kHz up to 18 GHz, offering excellent performance with high isolation, low SWR and fast switching speed. Applications include instrumentation, communications, radar, and many other test systems that require high speed RF and microwave SPDT switching.
-
U9397A -
Keysight Technologies
The Keysight U9397A solid state switch maximizes your frequency range from 300 kHz up to 8 GHz, offering excellent performance with high isolation, low SWR and fast switching speed. Applications include instrumentation, communications, radar, and many other test systems that require high speed RF and microwave SPDT switching.
-
Q8486D -
Keysight Technologies
Excellent SWR for reducing mismatch uncertainty50 MHz calibration port Accurate calibration and traceability to US National Institute of Standards and Technology (NIST) millimeter-wave sensor calibration Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters, plus the E1416A VXI and discontinued 70100A and 43X power meter Accurate average power measurements over -70 to -20 dBm Frequency range 33 GHz to 50 GHz Diode power sensing element
-
E9301A -
Keysight Technologies
Measure the average power of all modulation formats Wide dynamic range (-60 dBm to +20 dBm) and frequency range 10 MHz to 6 GHzHigh maximum power specification Low SWR for reducing mismatch uncertainty Calibration factors linearity and temperative compensation data stored in EEPROM Fast measurement speeds (up to 400 readings per second with the Keysight E4416A)Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
R8486D -
Keysight Technologies
Excellent SWR for reducing mismatch uncertainty50 MHz calibration port Accurate calibration and traceability to US National Institute of Standards and Technology (NIST) millimeter-wave sensor calibration Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters, plus the E1416A VXI and discontinued 70100A and 43X power meter Accurate average power measurements over -70 to -20 dBm Frequency range 26.5 GHz to 40 GHz Diode power sensing element