Showing results: 1 - 15 of 50 items found.
-
Model N100 -
Teledyne Advanced Pollution Instrumentation
The Model N100 instrument uses the proven UV-fluorescence principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of low-level Sulfur Dioxide (SO2) gas.
-
Model T100 -
Teledyne Advanced Pollution Instrumentation
The Model T100 uses the proven UV fluorescence principle, coupled with a state of the art user interface to provide easy, accurate, and dependable measurements of low level SO2.Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon 'kicker' and advanced optical design combine to prevent inaccuracies due to interferents.
-
AQMS-500 -
Focused Photonics Inc.
) analyzer applies UV fluorescence technology with the photomultiplier tube (PMT) to measure SO
-
Model T100U -
Teledyne Advanced Pollution Instrumentation
The Model T100U Trace-level SO2 analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven UV fluorescence principle, and is designed to allow ultra-sensitive SO2 measurements while still meeting the requirements for use as a US EPA compliance analyzer.The analyzer uses both the light and dark phases of the pulsed UV light source to continuously detect and correct for electronic noise, giving exceptionally stable and sensitive performance. A separate UV detector allows the instrument to continuously correct for variations in lamp intensity. Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift, and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon "kicker" and advanced optical design combine to prevent inaccuracies due to interferents.
-
Model N100H -
Teledyne Advanced Pollution Instrumentation
The Model N100H instrument uses the proven UV fluorescence principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of high range SO2 gas. The instrument includes interferent rejection, providing a simple and precise solution for a broad range of continuous emission monitoring systems (CEMS) and stack testing applications.
-
Model T100H -
Teledyne Advanced Pollution Instrumentation
The Model T100H SO2 analyzer uses the proven UV fluorescence principle with the high measurement ranges and interferent rejection needed for extractive source monitoring. The Model T100H provides a simple but precise solution for a broad range of CEM and stack testing applications.The instrument design provides minimal quenching by O2 or CO2 and less than a 0.1% response to water in the sample. Additionally, special optical filtering reduces the effects of NO interference.
-
Focused Photonics Inc.
Mobile air quality monitoring system consists of analysis devices, an automatic sampler, an image acquisition device, and a mobile communication device. Instruments combination can be selected and moved as per requirement, such flexibility enables the mobile station to perform as fixed station as well.
-
AQMS-3000 -
Focused Photonics Inc.
Micro AQMS gives a macro indication in terms of trend analysis against stationary AQI analysis. The micro AQMS is to find out the pattern of spatial pollution distribution during a certain period. These data support AQI results at the standard station, and most importantly, It gives a macro idea on municipal management.
-
AQMS-1000M -
Focused Photonics Inc.
The Compact system is the alternative solution against standard AQMS, it comes with integrated shelter consisting IPC, sampler, AC and all necessary accessories.
-
AQMS-550 -
Focused Photonics Inc.
AQMS-550 is equipped with an internally mounted catalytic converter set at 315°C to convert H2S to SO2. Bypassing the sample through an SO2 scrubber which removes any SO2, the H2S is converted to SO2 using this internal H2S converter and measured using the pulsed fluorescence technique.AQMS-550 H2S analyzer adopts UV fluorescence principle with an internal thermal catalytic converter to measure H2S in ambient air at levels commonly required.
-
Model 6400TH -
Teledyne Analytical Instruments
The 6400T Series analyzers uses a proven UV fluorescence principle coupled with state-of-the-art microprocessor technology to provide accurate and dependable measurements of low level SO2. The 6400T-H2S measures hydrogen sulfide (H2S) by incorporating a catalytic converter set at 600°F (315°C) to oxidize H2S into SO2 while leaving other more difficult to oxidize sulfurs unconverted. A switching mode allows analysis of both H2S and SO2 concurrently.
-
Model 6400T -
Teledyne Analytical Instruments
The 6400T Series analyzers uses a proven UV fluorescence principle coupled with state-of-the-art microprocessor technology to provide accurate and dependable measurements of low level SO2. The 6400T-H2S measures hydrogen sulfide (H2S) by incorporating a catalytic converter set at 600°F (315°C) to oxidize H2S into SO2 while leaving other more difficult to oxidize sulfurs unconverted. A switching mode allows analysis of both H2S and SO2 concurrently.
-
Model T108 -
Teledyne Advanced Pollution Instrumentation
The Model T108 Total Sulfur analyzer is designed to measure mixed sulfur impurities, collectively referred to as Total Sulfides, in air or carbon dioxide gas. Since there is no scrubber in the system, the instrument reading is the sum of the oxidized sulfur compounds and SO2.The Model T108 consists of a modified Model T100 SO2 analyzer with special software and a Model 501TS high temperature thermal oxidizer. Sulfur compounds are heated as they pass through the converter and oxidized into SO2. When analyzing CO2, which generally contains no oxygen, approximately 6% O2 is added to the sample before entering the converter. This dilution is corrected in the calibration procedure.
-
Model T101 -
Teledyne Advanced Pollution Instrumentation
The Model T101 H2S analyzer uses the proven UV fluorescence principle to measure hydrogen sulfide at levels commonly required for ambient air monitoring.The Model T101 is equipped with an internally mounted catalytic converter set at 315C to convert H2S to SO2. A switching mode alternately measures H2S and SO2 while showing both readings concurrently on the front display.
-
Figaro Engineering Inc.
Figaro USA offers a wide variety of gas sensors and gas modules ranging from ammonia, CO2, CO, SO2, and many others.