Showing results: 31 - 45 of 74 items found.
-
72-13625 -
Tenma
This 72-13625 is a manual range, benchtop digital Multimeter that features 19999 display counts, large LCD screen with backlight, full scale overload protection and a unique design. This instrument can be used to measure AC and DC voltage, AC and DC current, resistance, frequency, capacitance, transistor, hFE, diode (LED), SCR, continuity, etc.
-
SCR ELEKTRONIKS
SCR ELEKTRONIKS have developed ENDURANCE TEST PANEL FOR MIXER for carrying out endurance test of mixer at final stage. It consists of Voltmeter, Ammeter, Wattmeter & Temperature Indicator for observing the values of different parameters. Output Socket is provided for quick connections and disconnections of the equipment to be tested. User friendly operations make the equipment to be handled easier for any operator.
-
SCR ELEKTRONIKS
SCR ELEKTRONIKS have developed "60 Stations Preheating Test Setup for Hair Straightener“ for Testing of Hair Straightener. It consists of Adjustable Constant Voltage source, Digital Timer, Digital Voltmeter, Digital Timer for carrying out Heating Test of Hair Straightener. It has got the capacity to check hair straightener that require test current 28 A at different Test Voltages.
-
TSCT (Average Sensing) / TFCT (TRUE RMS) -
Kusam Electrical Industries Limited
• Transform Input: AC 5~400A directly into DC 4~20mA, no need external CT.• Suitable for application with high waveform distortion :(Frequency converter, Motor, SCR )• High accuracy <0.5%• High response time• High stability, easy connection.
-
SCR ELEKTRONIKS
SCR ELEKTRONIKS focuses on designing a solution around the end use at her customer. Instead of offering a standard instrument for a specific task, we have an approach of customizing the test bench to target the specific goals of the process or test procedure. Our measurement instruments, test modules, electrical power systems & software libraries are developed with this vision, thereby reducing the test system’s time-to-deploy.
-
SCR ELEKTRONIKS
The SCR Elektroniks 3 station MCB 28 Days and Temperature Rise Test Bench is economically designed to verify the 28 Days Test (21 hr ON, 3 hr OFF Test) as per clause 9.9 of IEC 60898-1 and Temperature Rise of the parts of a Circuit Breaker specified in Table 6 of clause 8.4.1 measured under the conditions specified in clause 9.8.2 of IEC 60898-1.
-
SCR ELEKTRONIKS
The SCR Elektroniks 3 station MCB Temperature Rise and Power Loss Test Bench is economically designed to verify temperature rise and measure power loss as per clause 9.8 of IEC 60898 with the circuit designed to follow test procedure as per Cl 9.8.2. The temperature rise is measured in accordance with Cl 9.8.3 and 9.8.4 while power loss is measured and verified as per Table 15 of Cl 9.8.5.
-
SCR ELEKTRONIKS
SCR ELEKTRONIKS have developed SECONDARY CURRENT INJECTION TEST TROLLEY for Switchgear items, CT manufacturer and where three phase current application is called for. It is low Voltage, 3 phase Current source with control circuitry, digital read out for test current and trip time measurement. We can select different CT ranges for each phase independently and adjust the current as per the required test Current.
-
72-13620 -
Tenma
*True RMS bench top digital multimeter with 6000 counts display*CAT II 600V safety rating*Manual function select and auto ranging*Transistor & SCR measurement*Data hold, max/min modes*EBTN (Enhanced Black Twisted Nematic) LCD backlight*USB interface*Input protection*Powered by 100V/120V/220V/240V ±10%, 47Hz to 63Hz supply*12-month limited warranty *view Terms & Conditions for details
-
SCR ELEKTRONIKS
SCR ELEKTRONIKS introduces Safety Test Panel for Luminaire with PC Datalogging. The tests are Performed as Prescribed in IS the Panel Carries out different tests one by one and provides indication of the Test results as OK or NOT-OK. It is very useful and handy in line testing on Mass production line as well as type Testing.
-
SCR ELEKTRONIKS
SCR Elektroniks make CORD SWIVELING TEST SET UP FOR HAIR DRYER & HAIR STRAIGHTENER is used to test the Electrical accessories / appliances for their mechanical strength. Operate appliances Hair dryer or Hair straightener at rate voltage. Position appliances swivel with connection with major axis horizontal ,supply cord hanging vertically with 1N pull force. Rotate the appliance around its major axis,20 Revolutions clockwise & 20 Revolutions anti-clockwise.
-
SCR ELEKTRONIKS
SCR Elektroniks make CORD FLEXING TEST SET UP FOR HAIR DRYER & HAIR STRAIGHTENER is used to test the Electrical accessories / appliances for their mechanical strength. Operate appliances Hair dryer or Hair straightener at rate voltage. Position appliances swivel with connection with major axis horizontal ,supply cord hanging vertically with 1N pull force. Rotate the appliance around its major axis, Clockwise & Anti-clockwise. Frequency is 10 turns in one minute.
-
2000A -
SCR ELEKTRONIKS
SCR ELEKTRONIKS have developed “TEMPERATURE RISE TEST BENCH FOR MEDIUM VOLTAGE SWITCH BOARDS” to measure rise in temperature at various points as mentioned in standard at junctions. The set-up consists of a True RMS Constant Current Source (to maintain the Current within + / - 1 % of set value with Digital Indication), PC based control system, Temperature data logging on PC, Servo-Controller and other indications. Digital voltmeter Primary Voltage) indicates the position of auto transformer (variac).
-
MODEL VES-3000 -
TEK-VAC INDUSTRIES Inc.
TEK-VAC's VES-3000 coater station model offers a modular concept for thin film deposition. Common PVD techniques which can be employed in this compact unit include thermal and electron beam evaporation. A 2KVA SCR controlled filament evaporation power supply is provided. Optional ion deposition and magnetron sputtering devices can be incorporated in the system.
-
SCR ELEKTRONIKS
SCR ELEKTRONIKS have developed primary and secondary Current injection test trolley for Switchgear manufacturers for testing of ACB , MCB , MCCB. It is low Voltage high Current source with control circuitry, digital read out for test current and trip time measurement. We can select different links of CT range as per the required test Current.