Showing results: 1 - 13 of 13 items found.
-
Smartech Inc.
Portable Handheld models capable of simulation & measurement of RTD & Thermocouple signals.
-
Pickering Interfaces Ltd.
Simulation of resistance based temperature sensors such as positive or negative temperature coefficient thermistors. Resistance Temperature Detectors (RTDs) can be wire-wound or thin film. Our RTD simulator modules provide a cost-effective method of simulating both PT100 and PT1000 RTD sensor types that require fine setting resolution.
-
DP-cPCI-2709 -
Data Patterns Pvt. Ltd.
DP-cPCI-2709 RTD Simulator is ideal for applications of Resistance Temperature Detector(RTD) simulation requiring high resolution and low value resistances . DP-cPCI-2709 is offered in two factory selectable configurations of 4 channels and 2 channels depending on the resistance range needed. The 4 channel configuration offers resistance ranging from 30Wto 75Win steps of 50 mWresolution. This is ideal for applications where low Ohmic simulation is required. Similarly, the 2 resolution.
-
50-262-102 -
Pickering Interfaces Ltd.
This RTD Simulator is a PCI card that supports 6 channels of RTD simulation. The card can provides a setting resolution of <90mΩ (also available in <8mΩ - PT100) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
50-262-101 -
Pickering Interfaces Ltd.
This RTD Simulator is a PCI card that supports 6 channels of RTD simulation. The card provides a setting resolution of <8mΩ (also available in <90mΩ - PT1000version) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
40-262-001 -
Pickering Interfaces Ltd.
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the design principles of our 40-260 PXI Precision Resistor, this RTD simulator module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels.
-
40-262-201 -
Pickering Interfaces Ltd.
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the design principles of our 40-260 PXI Precision Resistor, this RTD simulator module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels.
-
40-262-102 -
Pickering Interfaces Ltd.
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
40-262-202 -
Pickering Interfaces Ltd.
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
40-262-002 -
Pickering Interfaces Ltd.
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
40-262-101 -
Pickering Interfaces Ltd.
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
M143 -
Clarke-Hess Communications Research
The M143 Multifunction calibrator is a cost saving solution for calibration of electric meters with up to 1000 V and 20 A. It offersa basic accuracy of 0.01% in DC voltage for calibration of 3 and 4 digit multimeters. The resistance function is covered byeight fix resistors in range from 10 to 100 M. The calibrator offers TC temperature sensor simulation. It can be deliveredoptionally as well with RTD temperature sensor simulator. Thanks to its small dimensions and low weight the unit can be usedeasily for field calibration work.